| 2012-09-06 10:46:00 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | FBC FLORIDA BUILDING CODE 2010 |
| | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL |
| | |
| | 1. THE PLAN SHOWS A RAMP, BUT NOT WHERE THE RAMP LEADS. |
| | IF THIS IS A REQUIRED ACCESSIBLE ENTRANCE/EXIT, SHOW |
| | THE ACCESSIBLE ROUTE. PLEASE SHOW THE FOLLOWING: |
| | LOCATION OF ACCESSIBLE PARKING SPACES AND ACCESS AISLES |
| | SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY |
| | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE |
| | ENTRANCE |
| | |
| | PLAN DOES NOT SHOW HOW THIS IS A PART OF AN ACCESSIBLE |
| | ROUTE. |
| | |
| | SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 206 |
| | (ACCESSIBLE ROUTE). |
| | |
| | 2. THIS APPEARS TO BE A PART OF A LARGER PROJECT, BUT |
| | WAS SUBMITTED AS A STAND ALONE PERMIT. THEREFORE, THIS |
| | PERMIT SHOULD INCLUDE ALL INFORMATION TO SHOW CODE |
| | COMPLIANCE. IT IS NOT CLEAR WHY THIS WASN'T SUBMITTED |
| | AS A REVISION; PLEASE CONTACT ME IF YOU WISH TO |
| | DISCUSS. |
| | |
| | 3. DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED FOR |
| | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS |
| | FS481. |
| | |
| | 4. PLEASE REVISE PLAN TO SHOW SCOPE, A2 A2-1. A |
| | CONSIDERABLE AMOUNT OF WORK IS SHOWN WHICH IS NOT |
| | DESCRIBED IN THE APPLICATION. APPLICATION STATES SLABS |
| | ARE IN THE "REAR" AND NEW HANDICAP RAMP IS IN "FRONT" |
| | BUT A2-1 SHOWS RAMP AND SLABS ON SAME SIDE. PLEASE |
| | REVISE PLAN TO CLEARLY SHOW WHAT IS TO BE REVIEWED AND |
| | PERMITTED UNDER THIS APPLICATION. |
| | |
| | |
| | |