Plan Review Details - Permit 12080523
Plan Review Stops For Permit 12080523
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-08-27 Cont ID  
Sent By rmcdouga Date 2012-08-27 Time 07:11 Rev Time 0.00
Received By rmcdouga Date 2012-08-27 Time 06:38 Sent To  
Notes
2012-08-27 07:33:35THIS IS NOT A SUBSTANTIAL IMPROVEMENT. ONLY THE
 ELEVATOR AND NEW EQUIPMENT ARE REQUIRED TO BE ABOVE
 7.5' BFE. AN ELEVATION CERTIFICATE FOR THE FINAL
 CONSTRUCTION IS REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-08-17 Cont ID  
Sent By rmcdouga Date 2012-08-16 Time 09:12 Rev Time 0.00
Received By rmcdouga Date 2012-08-16 Time 09:12 Sent To  
Notes
2012-08-16 10:02:462010 FBC
  
 DENIED BY BUILDING
  
 1) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE WHICH
 REQUIRES THE LOWEST FINISHED FLOOR AND EQUIPMENT TO BE
 LOCATED AT OR ABOVE THE MINIMUM ELEVATION OF 7'6" BFE
 (BASE FLOOD ELEVATION). THIS INCLUDES THE 6" FREEBOARD
 ESTABLISHED BY THE CITY OF WEST PALM BEACH'S FLOOD
 ORDINANCE. SPECIFY THE FINISH FLOOR ELEVATIONS FOR THE
 EXISTING STRUCTURE AND THE PROPOSED ELEVATOR AND
 EQUIPMENT ON THE PLANS AND SUBMIT A ELEVATION
 CERTIFICATE FOR THE PROPOSED EQUIPMENT. WPB CODE OF
 ORDINANCES CHAPTER 94, ARTICLE XVII SECTIONS 94-541
 THRU 94-547.(LESS THAN SUBSTANTIAL IMPROVEMENT)
  
 2) THE PLANS INDICATE THAT THE SERVICE STAIRS ARE TO BE
 DEMOLISHED SO THAT THE ELEVATOR CAN BE INSTALLED SO
 THAT THE EXISTING FLOOR OPENING FOR THE STAIR CAN BE
 USED. SHOW COMPLIANCE WITH FBC R311.4 WHICH REQUIRES
 VERTICAL EGRESS FROM THE SECOND FLOOR BUY A STAIRWAY IN
 ACCORDANCE WITH SECTION R311.7 ON THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-08-16 Cont ID  
Sent By rmcdouga Date 2012-08-16 Time 10:03 Rev Time 0.00
Received By rmcdouga Date 2012-08-16 Time 10:03 Sent To  
Notes
2012-08-16 10:03:53ALL ELECTRICAL EQUIPMENT IS REQUIRED TO BE ABOVE 7'6"
 BFE.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-08-27 Cont ID  
Sent By rmcdouga Date 2012-08-27 Time 07:11 Rev Time 0.00
Received By rmcdouga Date 2012-08-24 Time 13:33 Sent To  
Notes
2012-08-24 13:33:24SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-08-16 Cont ID  
Sent By rmcdouga Date 2012-08-16 Time 10:02 Rev Time 0.00
Received By rmcdouga Date 2012-08-16 Time 10:02 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved