Plan Review Details - Permit 12080395
| Plan Review Stops For Permit 12080395 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-10-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-30 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-30 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2012-10-30 11:54:49 | ****PROVISO**** | | | ****PROVIDE AT INSPECTION**** | | | ****REVISE PLAN AS NOTED**** | | | ****ISSUED AT OWNER/BUILDER'S RISK**** | | | | | | ****REVISION REQUIRED SUBJECT TO FIELD INSPECTOR'S | | | DISCRETION**** | | | | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FBC 107.2.1, ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | 2. PLANS SPECIFY "STRAPS" - SEE FAC9N-3, PRODUCT | | | APPROVAL REQUIRED FOR STRUCTURAL CONNECTORS, AND ALL | | | ELEMENTS TO BE SPECIFIED TO SHOW RESISTANCE TO WIND | | | LOADS FBC R 301.1, FBC 107.2.1. "STRAP" TO BE SPECIFIC | | | TO A CONNECTOR WHICH CAN RESIST THE SPECIFIED DESIGN | | | LOADS, PLEASE REVISE PLAN TO INCLUDE INFORMATION AND | | | PROVIDE PRODUCT APPROVAL. | | | | | | 3. THE PLAN IS CUT OFF ON THE RIGHT SIDE, PLEASE SUBMIT | | | COMPLETE LEGIBLE PLANS, FBC 107.2.1. | | | | | | 4. WALL FRAMING SPACING NOT INCLUDED IN PLAN (2X6 | | | BEARING WALL). | | | | | | 5. RAFTER TIE IS NOTED ON THE PLAN, BUT NOT SHOWN | | | GRAPHICALLY (SEC B-B), PROPOSED CONSTRUCTION NOT CLEAR | | | FBC R 301.1, FBC 107.2.1. | | | | | | 6. INCLUDE WIND DESIGN CRITERIA, FBC R 301.1. THIS | | | SHOULD INCLUDE WIND SPEED AND EXPOSURE CLASSIFICATION. | | | (170MPH EXPOSURE C). | | | | | | 7. PROVIDE WINDOW PRODUCT APPROVAL IN FIELD. IF THIS IS | | | NOT AN IMPACT PRODUCT, IMPACT PROTECTION (SHUTTER) WILL | | | BE REQUIRED. IF A SHUTTER IS USED, PROVIDE A PRODUCT | | | APPROVAL FOR THE SHUTTER AS WELL. | | | | | | SEPARATE PERMIT REQUIRED FOR ROOF (APPLICATION AND | | | PRODUCT APPROVAL) | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-30 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-08-30 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2012-08-30 14:34:45 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FBC 107.2.1, ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | 2. PLANS SPECIFY "STRAPS" - SEE FAC9N-3, PRODUCT | | | APPROVAL REQUIRED FOR STRUCTURAL CONNECTORS, AND ALL | | | ELEMENTS TO BE SPECIFIED TO SHOW RESISTANCE TO WIND | | | LOADS FBC R 301.1, FBC 107.2.1. "STRAP" TO BE SPECIFIC | | | TO A CONNECTOR WHICH CAN RESIST THE SPECIFIED DESIGN | | | LOADS, PLEASE REVISE PLAN TO INCLUDE INFORMATION AND | | | PROVIDE PRODUCT APPROVAL. | | | | | | 3. THE PLAN IS CUT OFF ON THE RIGHT SIDE, PLEASE SUBMIT | | | COMPLETE LEGIBLE PLANS, FBC 107.2.1. | | | | | | 4. WALL FRAMING SPACING NOT INCLUDED IN PLAN (2X6 | | | BEARING WALL). | | | | | | 5. RAFTER TIE IS NOTED ON THE PLAN, BUT NOT SHOWN | | | GRAPHICALLY (SEC B-B), PROPOSED CONSTRUCTION NOT CLEAR | | | FBC R 301.1, FBC 107.2.1. | | | | | | 6. INCLUDE WIND DESIGN CRITERIA, FBC R 301.1. THIS | | | SHOULD INCLUDE WIND SPEED AND EXPOSURE CLASSIFICATION. | | | | | | IF PLANS ARE NOT SIGNED AND SEALED BY A DESIGN | | | PROFESSIONAL LICENSED UNDER FS471 OR FS481 (ENGINEER OR | | | ARCHITECT), PLEASE ADDRESS THE FOLLOWING: | | | | | | 7. SEE FBC RESIDENTIAL 301.2.1.1, DESIGN IS TO BE IN | | | ACCORDANCE WITH ONE OF THE METHODS LISTED. PLEASE | | | SPECIFY AND REVISE PLAN TO INCLUDE DESIGN CRITERIA. | | | | | | IF USING A PRESCRIPTIVE METHOD, IT WOULD BE HELPFUL TO | | | PLAN REVIEW TO INDICATE ON WHICH PAGES THESE DETAILS | | | CAN BE LOCATED (ICC 600, AF & PA). | | | | | | IF USING ASCE 7-10, CALCULATINS MAY BE REQUIRED. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-30 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-08-30 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2012-08-16 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2012-08-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2012-08-14 |
Time |
09:14 |
Sent To |
B |
|
| Notes |
| 2012-08-14 06:50:31 | SENT TO ZONING |
|
|
|