Plan Review Details - Permit 12080215
| Plan Review Stops For Permit 12080215 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-15 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-15 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2012-10-15 17:49:00 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. IT IS NOT CLEAR HOW WIND PRESSURES HAVE BEEN | | | DETERMINED; COMPONENTS & CLADDING OR MWFRS? PRESSURES | | | TOO LOW FOR COMPONENTS & CLADDING, SEE FBC RESIDENTIAL | | | 301.1. | | | | | | 2ND REVIEW, ZONES 1 AND 3 PRESSURES TOO LOW BASED ON | | | TABLE, FBC R 301.2(2) AND (3). | | | | | | 2. OK | | | | | | 3. SEPARATE ROOF PERMIT IS REQUIRED, INFORMATIONAL | | | ONLY. | | | | | | 4. OK | | | | | | 5. (NEW COMMENT) PROVIDE STAIR DIMENSIONS, SEE FBC R | | | 311.7.4. IT IS NOT CLEAR WHAT THE 6" DIMENSION REFERS | | | TO, BUT DOES NOT COMPLY FOR EITHER TREAD OR RISER. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-29 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-08-29 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2012-08-29 13:48:30 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. IT IS NOT CLEAR HOW WIND PRESSURES HAVE BEEN | | | DETERMINED; COMPONENTS & CLADDING OR MWFRS? PRESSURES | | | TOO LOW FOR COMPONENTS & CLADDING, SEE FBC RESIDENTIAL | | | 301.1. | | | | | | 2. THIS PARCEL IS LOCATED IN EXPOSURE C, SEE FBC | | | RESIDENTIAL 301.2.1.4.3. | | | | | | 3. SEPARATE ROOF PERMIT IS REQUIRED, INFORMATIONAL | | | ONLY. | | | | | | 4. REVISE SITE PLAN TO SHOW DISTANCE TO PROPERTY LINE, | | | FBC R TABLE 302.1. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-15 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-03 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2012-10-10 16:38:28 | 10/10 TO SH DESK | | | | | 2012-10-04 14:14:55 | IN ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-29 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-08-08 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2012-08-08 10:45:24 | TO ZONING | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2012-10-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2012-10-05 |
Time |
13:54 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2012-08-14 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2012-08-14 |
Time |
|
Rev Time |
|
| Received By |
mdekle |
Date |
2012-08-08 |
Time |
|
Sent To |
B |
|
| Notes |
| 2012-08-14 08:37:33 | PURSUANT TO SEC. 94-74; THE PROPOSED ADDITION MUST BE A | | | MINIMUM OF 5 FEET FROM THE SIDE PROPERTY LINE. PLEASE | | | REVISE PLANS ACCORDINGLY. | | | | | | QUESTIONS: PLEASE CONTACT MURRIAH DEKLE @ 772-822-1442 |
|
|
|