Plan Review Details - Permit 12080184
Plan Review Stops For Permit 12080184
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-09-21 Cont ID  
Sent By rmcdouga Date 2012-09-21 Time 14:08 Rev Time 0.00
Received By rmcdouga Date 2012-09-21 Time 07:32 Sent To  
Notes
2012-09-21 14:08:16BUILDING PROVISO
  
 1) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 WINDOW MULLIONS (IF USED) PRIOR TO INSTALLATIONS AS
 REQUIRED BY DCA RULE 9N-3.
  
 2) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR IMPACT
 PROTECTION DEVICES WITH TWO COPIES OF A KEY PLAN AND
 INSTALLATION SCHEDULE. FBC R301.2.1.2 AND DCA RULE 9N-3

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-09-07 Cont ID  
Sent By rmcdouga Date 2012-09-07 Time 14:09 Rev Time 0.00
Received By rmcdouga Date 2012-09-05 Time 06:53 Sent To  
Notes
2012-09-07 09:16:292010 FBC
  
 DENIED BY BUILDING
  
 1) THE VALUE FOR THE SCOPE OF WORK INDICATED BY THE
 PLANS APPEARS TO BE UNDERESTIMATED ON THE PERMIT
 APPLICATION. THE PLANS INDICATE ADDING A BATHROOM
 INSIDE EXISTING SPACE, REPLACING PLUMBING FIXTURES,
 ADDING NEW A/C TO BOTH STRUCTURES, REPLACING KITCHEN
 CABINETS, INSTALLING NEW ELECTRIC SERVICE AND WIRING,
 INSTALLING INSULATION AND DRYWALL, INSTALLING NEW
 IMPACT RATED WINDOWS AND NEW BARREL TILE ROOF OVER THE
 ENCLOSED PORCH AND CONVERTING THE GARAGE AREA OF THE
 GUEST HOUSE TO LIVING AREA. SUBMIT 2 COPIES OF A
 DETAILED COST BREAK DOWN FOR EACH ITEM LISTED INCLUDING
 LABOR AND MATERIAL COSTS ALSO AND INCLUDE COST DESIGN
 FEES, OVERHEAD AND PROFIT. CITY AMENDMENTS 109.3
  
 2) BASED OF THE PROPERTY APPRAISER'S RECORDS THERE IS A
 216 SQUARE FOOT GARAGE THAT FORMS PART OF THE GUEST
 HOUSE. UNLESS PROOF CAN BE PROVIDED THAT THE GARAGE WAS
 CONVERTED TO LIVING SPACE WITH THE PROPER PERMITS AND
 INSPECTIONS, IT WILL BE CONSIDERED AS A GARAGE AND
 COUNTY IMPACT FEES MAY BE CHARGED WHEN CONVERTING TO
 LIVING SPACE. PROVIDE AREA TABULATIONS FOR EACH OF THE
 STRUCTURES ON THE PLANS. CITY AMENDMENTS 107.2.1.3 (
 ACCORDING TO THE RECORDS ON FILE THE GUEST-HOUSE WAS
 ORIGINALLY A GARAGE APARTMENT.)
  
 3) SPECIFY THE DESIGN CRITERIA (WIND-SPEED & EXPOSURE
 CATEGORY) ON THE PLANS. FBC R301.2.1.1 (THE WIND-SPEED
 WAS SPECIFIED AS 140 MPH ON THE PLANS. THIS IS
 INCORRECT. BASED ON THE 2010 FBC THE WIND-SPEED FOR
 THIS PROJECT IS 170 MPH VULT AND 132 MPH VASD.)
  
 4) COMPLIED.
  
 5) COMPLIED.
  
 6) COMPLIED.
  
 7) COMPLIED. HOWEVER, THE OWNER/AGENT IS REQUIRED TO
 SIGN AND DATE THE ENERGY CALCULATION FORM. 2010 FBC
 ENERGY CONSERVATION CHAPTER 4
  
 8) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 BARREL TILE ROOFING AS REQUIRED BY DCA RULE 9N-3.
 SPECIFY THE FASTENING METHOD FROM THE PRODUCT APPROVAL
 THAT WILL BE USED TO INSTALL THE ROOF TILE. IF POLYFOAM
 WILL BE USED, SUBMIT PRODUCT APPROVALS FOR IT. FBC
 R905.3 (PRODUCT APPROVALS FOR THE ROOF TILE WERE
 SUBMITTED. HOWEVER, THE METHOD OF ATTACHMENT WAS NOT
 SPECIFIED. THE METHOD OF ATTACHMENT THAT IS USED IS
 REQUIRED TO MEET OR EXCEED THE REQUIRED UPLIFT MOMENT.)
  
 9) NOT APPLICABLE.
  
 10) THE PLANS SPECIFY IMPACT RESISTANT WINDOWS,
 HOWEVER, THE PRODUCT APPROVALS THAT WERE SUBMITTED ARE
 FOR NON-IMPACT RESISTANT WINDOWS. FBC EXISTING BUILDING
 606.4 AND FBC R301.2.1.2 REQUIRES GLAZED OPENINGS TO BE
 PROTECTED FROM WIND-BOURNE DEBRIS. THE IMPACT
 PROTECTION DEVICES SHALL MEET THE LARGE MISSILE TEST OF
 ASTM E 1996, ASTM E 1886, SSTD 12 OR TAS 201, 202 AND
 203 OR AAMA 506. SUBMIT PRODUCT APPROVALS FOR THE
 IMPACT PROTECTION DEVICES. INCLUDE A KEY PLAN AND AN
 INSTALLATION SCHEDULE WITH ANCHOR TYPE AND SPACING. (
 ACCORDING TO SECTION 606.4 OF THE 2010 FBC EXISTING
 BUILDING, IF YOU ARE REPLACING MORE THAN 25 PERCENT OF
 THE AGGREGATE AREA OF THE GLAZED OPENINGS IN A DWELLING
 UNIT IN A 12-MONTH PERIOD, THEN THE NEW WINDOWS ARE
 REQUIRED TO HAVE IMPACT PROTECTION. THE OLD EXISTING
 CLAMSHELL FOLD DOWN SHUTTERS HAVE NOT BEEN TESTED TO
 SHOW THAT THEY MEET THE REQUIREMENTS OF THE LARGE
 MISSILE TEST OF ASTM E 1996, ASTM E 1886, SSTD 12 OR
 TAS 201, 202 AND 203 OR AAMA 506. THERE ARE
 MANUFACTURER'S THAT PRODUCE THIS TYPE OF SHUTTER THAT
 IS COMPLIANT WITH THE LARGE MISSILE TESTING, IF YOU
 WISH TO MAINTAIN THE PERIOD LOOK OF THE HOUSE.)
  
 11) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW THE
 REVIEW COMMENTS HAVE BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-08-08 Cont ID  
Sent By rmcdouga Date 2012-08-08 Time 14:27 Rev Time 0.00
Received By rmcdouga Date 2012-08-08 Time 07:04 Sent To  
Notes
2012-08-08 09:24:062010 FBC
  
 DENIED BY BUILDING
  
 1) THE VALUE FOR THE SCOPE OF WORK INDICATED BY THE
 PLANS APPEARS TO BE UNDERESTIMATED ON THE PERMIT
 APPLICATION. THE PLANS INDICATE ADDING A BATHROOM
 INSIDE EXISTING SPACE, REPLACING PLUMBING FIXTURES,
 ADDING NEW A/C TO BOTH STRUCTURES, REPLACING KITCHEN
 CABINETS, INSTALLING NEW ELECTRIC SERVICE AND WIRING,
 INSTALLING INSULATION AND DRYWALL, INSTALLING NEW
 IMPACT RATED WINDOWS AND NEW BARREL TILE ROOF OVER THE
 ENCLOSED PORCH AND CONVERTING THE GARAGE AREA OF THE
 GUEST HOUSE TO LIVING AREA. SUBMIT 2 COPIES OF A
 DETAILED COST BREAK DOWN FOR EACH ITEM LISTED INCLUDING
 LABOR AND MATERIAL COSTS ALSO AND INCLUDE COST DESIGN
 FEES, OVERHEAD AND PROFIT. CITY AMENDMENTS 109.3
  
 2) BASED OF THE PROPERTY APPRAISER'S RECORDS THERE IS A
 216 SQUARE FOOT GARAGE THAT FORMS PART OF THE GUEST
 HOUSE. UNLESS PROOF CAN BE PROVIDED THAT THE GARAGE WAS
 CONVERTED TO LIVING SPACE WITH THE PROPER PERMITS AND
 INSPECTIONS, IT WILL BE CONSIDERED AS A GARAGE AND
 COUNTY IMPACT FEES MAY BE CHARGED WHEN CONVERTING TO
 LIVING SPACE. PROVIDE AREA TABULATIONS FOR EACH OF THE
 STRUCTURES ON THE PLANS. CITY AMENDMENTS 107.2.1.3
  
 3) SPECIFY THE DESIGN CRITERIA (WINDSPEED & EXPOSURE
 CATEGORY) ON THE PLANS. FBC R301.2.1.1
  
 4) PROVIDE DIMENSIONED FLOOR PLAN OF THE NEW BATHROOM
 IN THE MAIN HOUSE SHOWING COMPLIANCE WITH FBC R307.1.
  
 5) PROVIDE WALL SECTIONS FOR ALL NEW AND EXISTING
 BEARING AND NON-BEARING WALLS. CITY AMENDMENTS 107.2.1
  
 6) SHOW COMPLIANCE WITH FBC R310.1 EMERGENCY ESCAPE AND
 RESCUE OPENING AT THE BEDROOM THAT WAS CONVERTED FROM A
 GARAGE.
  
 7) SUBMIT ENERGY CALCULATIONS SHOWING COMPLIANCE WITH
 2010 FBC ENERGY CONSERVATION CHAPTER 4 FOR EACH
 BUILDING.
  
 8) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 BARREL TILE ROOFING AS REQUIRED BY DCA RULE 9N-3.
 SPECIFY THE FASTENING METHOD FROM THE PRODUCT APPROVAL
 THAT WILL BE USED TO INSTALL THE ROOF TILE. IF POLYFOAM
 WILL BE USED, SUBMIT PRODUCT APPROVALS FOR IT. FBC
 R905.3
  
 9) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 STRUCTURAL WINDOW MULLIONS THAT WILL BE INSTALLED AS
 REQUIRED BY DCA RULE 9N-3.
  
 10) THE PLANS SPECIFY IMPACT RESISTANT WINDOWS,
 HOWEVER, THE PRODUCT APPROVALS THAT WERE SUBMITTED ARE
 FOR NON-IMPACT RESISTANT WINDOWS. FBC EXISTING BUILDING
 606.4 AND FBC R301.2.1.2 REQUIRES GLAZED OPENINGS TO BE
 PROTECTED FROM WINDBOURNE DEBRIS. THE IMPACT PROTECTION
 DEVICES SHALL MEET THE LARGE MISSILE TEST OF ASTM E
 1996, ASTM E 1886, SSTD 12 OR TAS 201, 202 AND 203 OR
 AAMA 506. SUBMIT PRODUCT APPROVALS FOR THE IMPACT
 PROTECTION DEVICES. INCLUDE A KEY PLAN AND AN
 INSTALLATION SCHEDULE WITH ANCHOR TYPE AND SPACING.
  
 11) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW THE
 REVIEW COMMENTS HAVE BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-09-07 Cont ID  
Sent By rmcdouga Date 2012-09-07 Time 06:51 Rev Time 0.00
Received By rmcdouga Date 2012-09-07 Time 06:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-08-09 Cont ID  
Sent By rlecky Date 2012-08-09 Time 09:28 Rev Time 0.00
Received By rlecky Date 2012-08-08 Time 16:19 Sent To Z
Notes
2012-08-08 17:04:58PROVISIO:
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT
 ALREADY EXIST WITHIN THE RESIDENCE. IF THE RESIDENCE
 HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE
 A CARBON MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET
 OF EACH ROOM USED FOR SLEEPING. 2010 FBC R314, 315
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR NEW
 GENERAL PURPOSE OUTLETS. NEC 210.12
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
  
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2012-08-22 Cont ID  
Sent By fmittner Date 2012-08-22 Time 13:24 Rev Time 0.00
Received By fmittner Date 2012-08-22 Time 13:24 Sent To  
Notes
2012-08-22 13:25:18WINDOWS MUST HAVE WHITE FRAMES, CLEAR GLASS

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2012-08-07 Cont ID  
Sent By fmittner Date 2012-08-07 Time 11:16 Rev Time 0.00
Received By fmittner Date 2012-08-07 Time 11:16 Sent To  
Notes
2012-08-10 14:00:46PROVIDE ROOFING MATERIAL PRODUCT APPROVALS.
2012-08-07 11:17:52NEED MORE INFORMATION. PLEASE SUBMIT CLEAR
 PLANS/NARRATIVE FOR WHICH WINDOWS ARE BEING REPLACED,
 SAME OPENING SIZE?, SAME STYLE 1/1 SH? CONTACT
 FRIEDERIKE MITTNER 822-1457 WITH QUESTIONS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-09-21 Cont ID  
Sent By rmcdouga Date 2012-09-21 Time 14:08 Rev Time 0.00
Received By rmcdouga Date 2012-09-13 Time 08:39 Sent To  
Notes
2012-09-14 08:40:43RM

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-09-07 Cont ID  
Sent By rmcdouga Date 2012-09-07 Time 14:09 Rev Time 0.00
Received By rmcdouga Date 2012-09-04 Time 15:51 Sent To  
Notes
2012-09-04 15:51:36EXPEDITED
 GAVE TO ROBBIE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-08-22 Cont ID  
Sent By rmcdouga Date 2012-08-22 Time 14:26 Rev Time 0.00
Received By rmcdouga Date 2012-08-07 Time 14:40 Sent To  
Notes
2012-08-07 14:40:27SENT TO R MCDOUGAL

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2012-10-02 Cont ID  
Sent By rmcdouga Date 2012-10-02 Time 10:23 Rev Time 0.00
Received By rmcdouga Date 2012-09-28 Time 09:20 Sent To  
Notes
2012-09-28 09:21:29INCOMING: PLANS HAVE BEEN SENT FOR IMPACT FEE
 ASSESSMENT, 1 SET LEFT ON TOP OF COUNTER, BROUGHT IN
 THROUGH INCOMING FILED BACK OF HOUSE UNDER "R" SMALL.
 JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2012-09-21 Cont ID  
Sent By rmcdouga Date 2012-09-21 Time 14:09 Rev Time 0.00
Received By rmcdouga Date 2012-09-21 Time 14:09 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2012-09-07 Cont ID  
Sent By rmcdouga Date 2012-09-07 Time 06:52 Rev Time 0.00
Received By rmcdouga Date 2012-09-07 Time 06:52 Sent To  
Notes
2012-09-07 06:52:53AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-08-08 Cont ID  
Sent By rmcdouga Date 2012-08-08 Time 14:28 Rev Time 0.00
Received By rmcdouga Date 2012-08-08 Time 14:28 Sent To  
Notes
2012-08-08 14:29:08AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE
 REQUIRED IF GARAGE IS CONVERTED TO LIVING SPACE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-09-05 Cont ID  
Sent By rmcdouga Date 2012-09-05 Time 08:59 Rev Time 0.00
Received By rmcdouga Date 2012-09-05 Time 06:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-08-08 Cont ID  
Sent By rmcdouga Date 2012-08-08 Time 08:45 Rev Time 0.00
Received By rmcdouga Date 2012-08-08 Time 08:45 Sent To  
Notes
2012-08-08 08:59:522010 FBC
  
 DENIED BY MECHANICAL
  
 1) THE SCOPE OF WORK ON THE SUBMITTED PLANS INDICATES
 THAT NEW A/C SYSTEMS WILL BE INSTALLED. SUBMIT
 MECHANICAL PLANS THAT INDICATE THE LOCATION AND SIZES
 OF THE DUCTWORK, THE SUPPLY AND RETURN GRILL SIZES AND
 THE CFMS AT EACH SUPPLY OUTLET. SPECIFY THE EQUIPMENT
 LOCATIONS AND PROVIDE AN EQUIPMENT SCHEDULE FOR EACH
 BUILDING ON THE PLANS. CITY AMENDMENTS 107.3.5.3
  
 2) SUBMIT TWO COPIES OF HEATING AND COOLING SIZING
 CALCULATIONS IN ACCORDANCE WITH ACCA MANUAL S BASED ON
 BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA
 MANUAL J OR OTHER APPROVED METHODS FOR EACH BUILDING.
 FBCR M1401.3
  
 3) SUBMIT TWO SETS OF ENERGY CALCULATIONS IN COMPLIANCE
 WITH THE 2010 FBC ENERGY CONSERVATION CHAPTER 4.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-08-08 Cont ID  
Sent By rmcdouga Date 2012-08-08 Time 08:22 Rev Time 0.00
Received By rmcdouga Date 2012-08-08 Time 07:27 Sent To  
Notes
2012-08-08 08:45:05THE VALUE OF THE WORK INDICATED ON THE APPLICATION IS
 $6500.00. BASED ON THE SCOPE OF PLUMBING WORK SPECIFIED
 ON THE PLANS, THE VALUE FOR THE PLUMBING PORTION OF THE
 WORK IS $3,600.00 BASED ON MARSHALL AND SWIFT
 VALUATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2012-08-10 Cont ID  
Sent By fmittner Date 2012-08-10 Time 13:56 Rev Time 0.00
Received By fmittner Date 2012-08-09 Time 15:53 Sent To  
Notes
2012-08-09 15:53:32GAVE TO F.M.