| 2012-08-02 11:05:18 | RESIDENTIAL (R1) RE-ROOF AND REPAIRS BUILDING REVIEW |
| | COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- A) ENGINEER TO PROVIDE COMPLETE DETAILS AND |
| | SPECIFICATIONS FOR NEW BEAMS AND COLUMNS. NEED TO |
| | SPECIFY ALL BEAM STRUCTURAL CONNECTORS AND COLUMNS |
| | CONNECTORS AT TOP AND BOTTOM AS REQUIRED BY SEC. |
| | 1604.8.1 OF 2010 FBC-BUILDING. |
| | |
| | B) ENGINEER TO REVISE APPLICABLE CODE SPECIFIED ON |
| | SHEET A-1. THE APPLICABLE CODE IS THE FBC-2010 NOT THE |
| | FLORIDA RESIDENTIAL CODE. SEC. 101.2 CITY AMENDMENTS TO |
| | FBC. |
| | |
| | C) SPECIFY THE ROOF PITCH AS REQUIRED BY SEC. 107.2.1.2 |
| | CITY AMENDMENTS TO FBC. |
| | |
| | 2- A) SPECIFY HOW IS THE CONCRETE TILE GOING TO BE |
| | INSTALLED. SPECIFY IF SCREWS (HOW MANY AND SIZE) OR |
| | ADHESIVE. IF USING ADHESIVE, THEN, SEE THE CONCRETE |
| | TILE NOA FOR LISTED ADHESIVE. AND, PROVIDE PRODUCT |
| | APPROVAL (2 COPIES) AS REQUIRED BY DCA RULE 9N-3 AND |
| | SEC. 107.2.1.2 OF CITY AMENDMENTS TO FBC. |
| | |
| | B) ENGINEER PLANS SPECIFY PEEL AND STICK CONCRETE TILE |
| | UNDERLAYMENT. PROVIDE PRODUCT APPROVAL DESIGNED FOR |
| | CONCRETE TILE INSTALLATION AS REQUIRED BY DCA RULE 9N-3 |
| | AND SEC. 107.2.1.2 CITY AMENDMENTS. |
| | |
| | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. REVISE AS REQUIRED TO INCLUDE RE-ROOFING AND |
| | INSTALLATION OF NEW BEAMS AND COLUMNS AS SHOWN ON |
| | PLANS. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | ENGINEERING FEES AND OVERHEAD AND PROFIT AS REQUIRED BY |
| | SEC. 109.3 CITY AMENDMENTS TO FBC. |
| | |
| | |