Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-08-15 Cont ID  
Sent By shill Date 2012-08-15 Time 10:42 Rev Time 0.00
Received By shill Date 2012-08-15 Time 10:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-08-10 Cont ID  
Sent By jwitmer Date 2012-08-10 Time 16:18 Rev Time 0.00
Received By jwitmer Date 2012-08-10 Time 16:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-08-10 Cont ID  
Sent By jwitmer Date 2012-08-10 Time 16:18 Rev Time 0.00
Received By jwitmer Date 2012-07-24 Time 11:14 Sent To  
Notes
2012-08-10 16:46:09BUILDING PLAN REVIEW
 PERMIT:
 ADD:
 CONT:
 TEL: (561)###-####
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) DISCREPANCIES IN PLANS AND PRODUCT APPROVALS.
 1) SHEET A-1 INDICATES THE WIND DESIGN TO THE 2010 FBC
 WITH A 140 MPH.1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION THE BASIC WIND SPEED, VU,
 SHALL BE DETERMINED IN ACCORDANCE WITH 1609.3.1 & ASCE
 7-10
  
 2) SHEET A-1 OCCUPANCY TYPE- SINGLE FAMILY RESIDENCE,
 THIS IA A 4 STORY BUILDING? UNIT 409? DISCREPANCY
 107.2.1.3 ADDITIONAL INFORMATION REQUIRED.
  
 3) A-1 WINDOW SCHEDULE IS FOR LAWSON WINDOWS WITH NOA #
 12-0127.13 THE NOA SUBMITTED IS FOR PGT WINDOWS
 11-1013.16. DISCREPANCY 107.2.1.3 ADDITIONAL
 INFORMATION REQUIRED.
  
 4) PRESSURES ON SHEET A-2 DO NOT INCLUDE HEIGHT
 ADJUSTMENT FACTORS FOR EXPOSURE "C"A HEIGHT AND
 EXPOSURE ADJUSTMENT COEFFICIENT, * SHALL BE DETERMINED
 FROM TABLE 1609.7.2. ASCE 7-10.
  
 5) PRESSURES ON SHEET A-2 DO NOT INDICATE IF THEY ARE
 VULT OR VASD TO COMPARE TO PRODUCT APPROVALS APPROVED
 UNDER VASD. COMPONENTS & CLADDING PRESSURES POSITVE &
 NEGATIVE TABLE 1609.2(2) .
  
 6) PRODUCT APPROVAL NOA 11-1013.16 PGT WINDOW SINGLW
 HUNG SH-800 DOES NOT INCLUDE MULLIONS .
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
2012-07-24 11:15:03INCOMING SENT TO ZONING BOX .JW

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2012-07-27 Time   Rev Time 0.00
Received By mdekle Date 2012-07-24 Time 16:37 Sent To B1
Notes
2012-08-09 14:47:29MASTER PERMIT (12050490) HAS SITE PLAN DEPICTING
 PROPOSED LOCATION. THE PROPOSAL IS NOT AN ACCESSORY
 STRUCTURE - SIMPLY A CANOPY AFFIXED TO TWO EXISTING
 STRUCTURES.
2012-07-27 13:20:51THE APPLICANT IS REQUESTED TO SUBMIT ADDITIONAL
 INFORMATION DEPICTING THE LOCATION OF THE PROPOSED
 CANOPY. QUESTIONS: PLEASE CALL PLANNER, MURRIAH DEKLE @