Plan Review Details - Permit 12070774
| Plan Review Stops For Permit 12070774 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-09-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-09-08 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-09-08 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2012-09-08 11:05:07 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- REPAIRS THAT ARE MORE THAN 25% OF THE ROOF AREA OR | | | ROOF SECTION REQUIRE ENTIRE ROOFING OR ROOF SECTION. | | | SEC. 611.1.1 OF 2010 FBC-EXISTING BUILDING. VALUE OF | | | WORK SHALL BE REVISED ACCORDINGLY IF COMPLETE | | | RE-ROOFING IS REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-07-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-07-31 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-07-31 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2012-07-31 10:57:00 | RESIDENTIAL (R2) CONCRETE ROOF TILE REPAIRS BUILDING | | | REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- ENGINEER TO REVISE CALCULATIONS SUBMITTED. | | | A) REVISE THE MOMENT OF RESISTANCE CALCULATIONS FOR | | | FIELD AND PERIMETER ZONES. KEEP IN MIND THAT THE DESIGN | | | PRESSURES ARE NEGATIVE WHEN RUNNING THE CALCULATIONS. | | | SEC. 107.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | B) CHECK THE HEIGHT OF THE BUILDINGS. ACCORDING TO OUR | | | RECORDS BUILDINGS ARE FOUR STORIES HIGH. THEREFORE, | | | 30'-0" HEIGHT NEEDS TO BE REVISED. REVISE CALCULATIONS | | | AS REQUIRED. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | 2- FOR YOUR INFORMATION: REPAIRS THAT ARE MORE THAN 25% | | | OF THE ROOF AREA REQUIRE RE-ROOFING THE ENTIRE ROOF. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-09-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-09-08 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-09-08 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-07-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-07-31 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-07-31 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
|