Plan Review Details - Permit 12070726
Plan Review Stops For Permit 12070726
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-10-01 Cont ID  
Sent By rmcdouga Date 2012-10-01 Time 10:30 Rev Time 0.00
Received By rmcdouga Date 2012-09-28 Time 11:17 Sent To  
Notes
2012-10-01 10:34:41REVISION REQUIRED
  
 SUBMIT TWO SETS OF RAS 117 CALCULATIONS FOR THE GAF
 BUILT-UP ROOF SYSTEM. FBC R301.2.1

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-09-11 Cont ID  
Sent By rmcdouga Date 2012-09-11 Time 14:06 Rev Time 0.00
Received By rmcdouga Date 2012-09-11 Time 08:14 Sent To  
Notes
2012-09-11 08:45:362010 FBC
  
 DENIED BY BUILDING
  
 1) THE STRUCTURE IS LOCATED WITHIN 600 FEET OF THE
 INTER-COASTAL WATERWAY, ACCORDING TO FBC R301.2.1.4.3
 THE EXPOSURE CATEGORY IS "D". PLEASE REVISE THE PLANS.
  
 2) SUBMIT A DRAINAGE PLAN THAT SHOWS THAT THE SURFACE
 WATER IS DIRECTED TO AN APPROVED COLLECTION POINT AS
 REQUIRED BY FBC R401.3.
  
 3) THE PLANS SHOW ATTIC VENTS FOR A VENTED ATTIC AND
 THE ENERGY CALCULATION FORM SPECIFIES A SINGLE ASSEMBLY
 UN-VENTED ATTIC. PLEASE REVISE SO THAT THE TWO ARE IN
 AGREEMENT. CITY AMENDMENTS 107.2.1
  
 4) SUBMIT TWO COPIES OF THE EVALUATION REPORT FOR THE
 SPRAY FOAM INSULATION THAT WILL BE USED IN THE
 UN-VENTED ATTIC. FBC R316
  
 5) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS AND LISTING FOR THE PRE-FAB FIREPLACE.
 CITY AMENDMENTS 107.2.1.3 & FBCR M1801.1
  
 6) SHOW COMPLIANCE WITH FBC R302.5.1 FOR THE DOOR
 BETWEEN THE GARAGE AND THE LIVING SPACE.
  
 7) PROVIDE STRUCTURAL DETAILS FOR THE ARCH OPENINGS ON
 THE PLANS.
  
 8) SPECIFY THE WALL TO TRUSS CONNECTORS AND UPLIFT
 LOADS ON THE ROOF FRAMING PLANS. FBC R802.1.6.5
  
 9) THE PLANS CALL OUT (2) 3080 FRENCH DOORS AT THE
 MASTER BEDROOM AND A 5' - 2" OPENING DIMENSION IS
 SPECIFIED. PLEASE CLARIFY.
  
 10) THE COMPONENT AND CLADDING WALL PRESSURES ARE VULT
 (ULTIMATE DESIGN WIND SPEED) AND THE PRODUCT APPROVALS
 ARE BASED ON VASD (NOMINAL DESIGN WIND SPEED). BECAUSE
 OF THIS THE DESIGN PRESSURES IN THE PRODUCT APPROVALS
 FOR THE WINDOWS AND DOORS ARE LOWER THAN THE ONES
 SPECIFIED IN THE TABLE ON SHEET ONE. PLEASE REVISE THE
 TABLE. FBC R301.2.1.3
  
 11) THE PRODUCT APPROVALS REQUIRED BY DCA RULE 9N-3 ARE
 REQUIRED TO BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. CITY AMENDMENTS 107.3.4.1
  
 12) SUBMIT 2 COPIES OF THE PRODUCT APPROVALS REQUIRED
 BY DCA RULE 9N-3. ONLY ONE SET WAS SUBMITTED. CITY
 AMENDMENTS 107.1
  
 13) SUBMIT 2 COPIES OF THE PRODUCT APPROVALS FOR THE
 STRUCTURAL MULLIONS, THE 1/2 ROUND FIXED WINDOWS ABOVE
 THE FRENCH DOORS, THE ROOFING MATERIAL FOR THE FLAT
 ROOF. DCA RULE 9N-3
  
 14) THE FLORIDA PRODUCT APPROVAL THAT WAS SUBMITTED FOR
 THE OVERHEAD GARAGE DOOR #7768 IS FOR THE 2007 FBC.
 SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE 2010 FBC
 FOR THESE DOORS. DCA RULE 9N-3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-07-31 Cont ID  
Sent By rlecky Date 2012-07-31 Time 15:53 Rev Time 0.00
Received By rlecky Date 2012-07-31 Time 13:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2012-10-04 Time   Rev Time 0.00
Received By lmartine Date 2012-10-01 Time 17:58 Sent To  
Notes
2012-10-02 17:59:13IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-10-01 Cont ID  
Sent By rmcdouga Date 2012-10-01 Time 10:31 Rev Time 0.00
Received By rmcdouga Date 2012-09-18 Time 08:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-09-11 Cont ID  
Sent By rmcdouga Date 2012-09-11 Time 14:06 Rev Time 0.00
Received By rmcdouga Date 2012-07-20 Time 17:39 Sent To  
Notes
2012-07-23 17:45:08R--8

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2012-09-05 Cont ID  
Sent By rmcdouga Date 2012-09-05 Time 09:52 Rev Time 0.00
Received By rmcdouga Date 2012-09-05 Time 09:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-09-10 Cont ID  
Sent By rmcdouga Date 2012-09-10 Time 10:20 Rev Time 0.00
Received By rmcdouga Date 2012-09-10 Time 10:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-09-10 Cont ID  
Sent By rmcdouga Date 2012-09-10 Time 10:20 Rev Time 0.00
Received By rmcdouga Date 2012-09-05 Time 09:52 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2012-10-04 Cont ID  
Sent By mdekle Date 2012-10-04 Time   Rev Time 0.00
Received By mdekle Date 2012-10-03 Time   Sent To  
Notes
2012-10-04 14:16:36PROVISOS IMPOSED ON PLAN. PROPERTY OWNER (PAUL HITT) IS
 IN AGREEMENT WITH PROVISO REGARDING ELIMINATION OF
 CIRCULAR DRIVEWAY AND REDUCTIION OF STRAIGHT DRIVE TO
 20' FEET IN WIDTH. APPROVED PLANS HAVE BEEN MARKED
 ACCORDINGLY WHICH DEPICT THESE CHANGES. THE
 FOURTHCOMING LANDSCAPE PLAN WILL REFLECT THE INCREASED
 OPEN SPACE CALCULATIONS, ETC.

Review Stop Z ZONING
Rev No 2 Status F Date 2012-09-20 Cont ID  
Sent By mdekle Date 2012-09-20 Time   Rev Time 0.00
Received By mdekle Date 2012-09-20 Time   Sent To  
Notes
2012-09-20 14:52:02PLANNING AND ZONING: ***** FAILED****
  
 PLEASE RESPOND TO COMMENTS IN WRITING:
  
 I. PURSUANT TO SECTION SEC. 94-482. - PARKING
 REQUIREMENTS FOR LESS THAN THREE RESIDENTIAL DWELLING
 UNITS: THE PROPOSED DRIVEWAY WIDTH EXCEEDS THE MAXIMUM
 ALLOWABLE WIDTH FOR CIRCULAR DRIVEWAYS.
  
 (A)LOCATION AND SURFACE. REQUIRED OFF-STREET PARKING
 SPACES FOR LESS THAN THREE RESIDENTIAL DWELLING UNITS
 SHALL BE PROVIDED ON THE PROPERTY ON WHICH THE UNITS
 ARE LOCATED. REQUIRED PARKING MAY BE LOCATED IN A FRONT
 YARD; HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75
 PERCENT OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH
 LIVING PLANT MATERIAL (SUCH AS GRASS, GROUND COVER,
 SHRUBS, HEDGES, VINES OR TREES).
  
 NOTWITHSTANDING THE PRECEDING PARAGRAPH, LOCATIONS
 WHERE OFF-STREET PARKING SPACES, DRIVEWAYS, PATIOS
 AND/OR WALKWAYS IN THE FRONT YARD EXCLUSIVELY CONSIST
 OF A PERMEABLE PAVER SYSTEM, 60 PERCENT OF THE FRONT
 YARD AREA SHALL BE LANDSCAPED WITH LIVING PLANT
 MATERIAL (SUCH AS GRASS, GROUND COVER, SHRUBS, HEDGES,
 VINES OR TREES).
  
 PARKING AREAS LOCATED IN THE FRONT YARD SHALL BE
 SURFACED WITH A NONDUSTING SURFACE IN COMPLIANCE WITH
 SUBSECTION 94-485(E). IT SHALL BE A VIOLATION OF THIS
 CHAPTER TO PARK ON ANY UNPAVED AREAS AS DESCRIBED IN
 THIS ARTICLE.
  
 (B)CONFIGURATION. REQUIRED OFF-STREET PARKING AREAS
 SHALL CONSIST OF A PARKING BAY, STALL, DRIVEWAY,
 GARAGE, OR COMBINATION THEREOF. REFER TO SUBSECTION
 94-313(1)B.3 FOR ACCESS POINT REQUIREMENTS.
  
 (C)RETENTION OF REQUIRED OFF-STREET PARKING SPACES.
 REQUIRED OFF-STREET PARKING SPACES SHALL NOT BE
 REPLACED BY ANY OTHER ON-SITE FACILITY UNLESS EQUAL
 PARKING FACILITIES ARE PROVIDED ELSEWHERE. OFF-STREET
 PARKING SPACES EXISTING ON THE EFFECTIVE DATE OF THE
 ORDINANCE FROM WHICH THIS ARTICLE IS DERIVED SHALL NOT
 BE REDUCED TO AN AMOUNT LESS THAN REQUIRED.
  
 (D)SETBACK FROM PROPERTY LINES; REPAIR AND REPLACEMENT.
  
 (1)NEW OFF-STREET PARKING SPACES AND DRIVEWAYS WITHIN A
 FRONT YARD OR A CORNER SIDE YARD SHALL BE SET BACK A
 MINIMUM OF FIVE FEET FROM A FRONT AND/OR CORNER SIDE
 PROPERTY LINE AND THREE FEET FROM A SIDE OR REAR
 PROPERTY LINE, EXCEPT FOR THAT PORTION OF THE DRIVEWAY
 ADJOINING THE APRON.
  
 (2)EXPANSIONS TO EXISTING OFF-STREET PARKING SPACES AND
 DRIVEWAYS WITHIN A FRONT YARD OR A CORNER SIDE YARD
 SHALL BE SET BACK A MINIMUM OF FIVE FEET FROM A FRONT
 AND/OR CORNER SIDE PROPERTY LINE AND THREE FEET FROM A
 SIDE OR REAR PROPERTY LINE, EXCEPT FOR THAT PORTION OF
 THE DRIVEWAY ADJOINING THE APRON.
  
 (3)EXISTING OFF-STREET PARKING SPACES AND DRIVEWAYS
 WHICH ARE NOT SET BACK A MINIMUM OF FIVE FEET FROM A
 FRONT OR CORNER SIDE PROPERTY LINE AND THREE FEET FROM
 A SIDE OR REAR PROPERTY LINE MAY BE REPAIRED AS PART OF
 NORMAL MAINTENANCE.
  
 (4)EXISTING OFF-STREET PARKING SPACES AND DRIVEWAYS
 WHICH ARE NOT SET BACK A MINIMUM OF FIVE FEET FROM A
 FRONT AND/OR CORNER SIDE PROPERTY LINE AND THREE FEET
 FROM A SIDE OR REAR PROPERTY LINE MAY BE REPLACED IN
 THE EXACT LOCATION OR WITH A GREATER SETBACK THAN
 CURRENTLY EXISTS.
  
 (5)FOR CIRCULAR DRIVEWAYS THE INTERIOR ARC MAY BE AN
 IRREGULAR SHAPE, BUT SHALL HAVE A MINIMUM RADIUS OF
 FIVE FEET, AS DEPICTED IN FIGURE XV-1. THE INTERIOR ARC
 SHALL BE LANDSCAPED WITH LIVING PLANT MATERIAL.
  
 (CODE 1979, ? 33-171; ORD. NO. 4370-11, ? 4, 10-3-2011)
  
 II. PURSUANT TO SECTION SEC. 94-72 OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS ("ZLDR"), THE MINIMUM
 SETBACKS FOR PRINCIPAL BUILDING IN A SINGLE-FAMILY LOW
 DENSITY ("SF7") RESIDENTIAL DISTRICT IS AS FOLLOWS:
  
 A. FRONT: 25 FEET;
 B. CORNER: 12.5 FEET;
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
 THE PROPOSED REAR SETBACK OF THE HOUSE DOES NOT COMPLY.
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE APPLICABLE CITY CODES ON WWW.MUNICODE.COM.
  
  
 MURRIAH DEKLE, MPA
 PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2012-10-04 Cont ID  
Sent By mdekle Date 2012-07-30 Time   Rev Time  
Received By mdekle Date 2012-07-30 Time   Sent To  
Notes
2012-07-30 11:54:33PLANNING AND ZONING: ***** FAILED****
  
 PLEASE RESPOND TO COMMENTS IN WRITING:
  
 1. THE ADDRESS, STREET NAME AND SKETCH ON THE SURVEY
 DOES NOT CORRESPOND WITH THE PROPOSED SITE PLAN, FLOOR
 PLAN, ETC. PLEASE REVISE.
 2. PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR WHICH CAN BE FOUND ONLINE @WWW.MUNICODE.COM
 3. THE PROPOSED SITE PLAN MUST INDICATE THE SETBACK
 DIMENSIONS FROM THE PROPOSED A/C EQUIPMENT TO ALL
 PROPERTY LINES. AS PER SECTION 94-305(B)(4) OF THE
 ZONING CODE ("ZLDR"): MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
 4. PURSUANT TO SECTION SEC. 94-72 OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS ("ZLDR"), THE MINIMUM
 SETBACKS FOR PRINCIPAL BUILDING IN A SINGLE-FAMILY LOW
 DENSITY ("SF7") RESIDENTIAL DISTRICT IS AS FOLLOWS:
 A. FRONT: 25 FEET;
 B. CORNER: 12.5 FEET;
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL
 PLEASE BE ADVISED; THE PROPOSED EAST (SIDE) SETBACK
 DOES NOT COMPLY.
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  