Plan Review Details - Permit 12070612
| Plan Review Stops For Permit 12070612 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-02-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-02-28 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-28 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-02-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-02-22 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-22 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2013-02-22 10:56:08 | ****CORRECTIONS**** | | | SUBMITTAL FROM 2/19/13 | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: DOOR LOCATIONS, WINDOW | | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE | | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | | FOR BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | 2ND/3RD REVIEW, INCLUDE MISSING INFORMATION: ROOM | | | DESIGNATIONS, TYPE OF EXISTING WINDOWS (EXAMPLE - | | | CASEMENT, SINGLE HUNG, ETC.) AND CURRENT CLEAR OPENING | | | SIZE AND PROPOSED CLEAR OPENING SIZE. | | | | | | 2. A DOOR PRODUCT APPROVAL WAS SUBMITTED, BUT THIS IS | | | FOR A NON IMPACT DOOR. IMPACT PROTECTION REQUIRED FBC R | | | 301.2.1.2. IF SHUTTERS ARE PROPOSED, PROVIDE PRODUCT | | | APPROVALS AND COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM | | | /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF) | | | | | | IF AN IMPACT DOOR IS PROPOSED, PROVIDE A PRODUCT | | | APPROVAL FOR AN IMPACT RATED DOOR. | | | | | | | | | | | | 3. PROVIDE A REASONABLE VALUE FOR THIS JOB, FBC 109. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-02-20 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-20 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2013-02-20 06:43:05 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: DOOR LOCATIONS, WINDOW | | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE | | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | | FOR BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | 2ND REVIEW, INCLUDE MISSING INFORMATION: ROOM | | | DESIGNATIONS, TYPE OF EXISTING WINDOWS (EXAMPLE - | | | CASEMENT, SINGLE HUNG, ETC.) AND CURRENT CLEAR OPENING | | | SIZE AND PROPOSED CLEAR OPENING SIZE. | | | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9N-3. FOR THE DOORS, PROVIDE THE FLORIDA STATE | | | PRODUCT APPROVAL COVER SHEET, AVAILABLE AT | | | WWW.FLORIDABUILDING.ORG. | | | | | | NEW COMMENT: | | | | | | 3. PROVIDE A REASONABLE VALUE FOR THIS JOB, FBC 109. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-07-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-25 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-25 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2012-07-25 08:57:01 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: DOOR LOCATIONS, WINDOW | | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE | | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | | FOR BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9N-3. FOR THE DOORS, PROVIDE THE FLORIDA STATE | | | PRODUCT APPROVAL COVER SHEET, AVAILABLE AT | | | WWW.FLORIDABUILDING.ORG. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-02-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-02-28 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-28 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-02-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-02-22 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-19 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2013-02-19 16:28:53 | GAVE TO SAMANTHA | | | PRODUCT APPROVALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-02-20 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-12 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-07-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-25 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-18 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2012-07-19 12:37:53 | MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy