Plan Review Details - Permit 12070387
Plan Review Stops For Permit 12070387
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-09-11 Cont ID  
Sent By jwitmer Date 2012-09-11 Time 10:58 Rev Time 0.00
Received By jwitmer Date 2012-09-11 Time 10:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-07-27 Cont ID  
Sent By jwitmer Date 2012-07-27 Time 12:05 Rev Time 0.00
Received By jwitmer Date 2012-07-27 Time 11:58 Sent To  
Notes
2012-07-27 12:21:14BUILDING PLAN REVIEW
 PERMIT: 12070387
 ADD: 319 CLEMATIS ST # 708
 CONT: RIELLY CONSTRUCTION
 TEL: (561)262-6876
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) THE PLANS DO NOT INDICATE WALLS TO BE DEMOLISHED,
 THE MINITURE FLOOR PLAN INDICATES WORK ON THE 7TH
 FLOOR, THE WRITTEN DOCUMENT INDICATES WORK ON THE 3RD
 FLOOR,
 IT APPEARS THERE MAY BE INFILL WALLS BEHIND THE
 ELEVATOR AS WELL AS THE ROOM BEHIND ROOM 712. 2010
 FBC-B 107.2.1.4* QUALITY OF BUILDING PLANS. BUILDING
 PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
  
 2) THE PERMIT APPLICATION INDICATES RENOVATIONS TO THE
 KITCHEN AREA OF SUITE # 708, PLANS ARE DEFICIENT IN
 PROVIDING DETIALS OF CODE COMPLIANCE FOR ACCESSIBILITY
 TO THE KITCHEN SINK, 2010 FBC-B 606.3 HEIGHT
 REQUIREMENTS AND 606.2 CLEAR FLOOR SPACE.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-09-17 Cont ID  
Sent By rlecky Date 2012-09-17 Time 07:48 Rev Time 0.00
Received By rlecky Date 2012-09-17 Time 07:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-07-23 Cont ID  
Sent By rlecky Date 2012-07-23 Time 15:23 Rev Time 0.00
Received By rlecky Date 2012-07-23 Time 15:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-09-14 Cont ID  
Sent By ddaniels Date 2012-09-14 Time 11:13 Rev Time 0.00
Received By ddaniels Date 2012-09-14 Time 11:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-07-17 Cont ID  
Sent By wjolin Date 2012-07-17 Time 10:38 Rev Time 0.00
Received By wjolin Date 2012-07-17 Time 10:05 Sent To  
Notes
2012-07-17 10:07:40319 CLEMATIS STREET - SUITE #708
 PERMIT #12070387
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET M-2: EXISTING DUCTWORK PENETRATING FIRE RATED
 BARRIERS DO NOT INDICATE EXISTING FIRE DAMPERS.
  
 SHEET E-4: NO EMERGENCY LIGHTING OR FIRE ALARM
 NOTIFICATION APPLIANCES SHOWN ON PLAN.
  
 SHEET FS-1: SEVERAL FIRE SPRINKLERS ARE PROVIDING
 INADEQUATE PROTECTION FOR THE AREA OR ROOM THEY ARE
 SERVING.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-09-14 Cont ID  
Sent By ddaniels Date 2012-09-14 Time 11:14 Rev Time 0.00
Received By ddaniels Date 2012-09-07 Time 12:13 Sent To  
Notes
2012-09-07 12:13:28B--5

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-08-02 Cont ID  
Sent By hmoser Date 2012-08-02 Time 14:39 Rev Time 0.00
Received By hmoser Date 2012-07-12 Time 16:04 Sent To  
Notes
2012-07-13 16:05:10SENT TO B8 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-09-11 Cont ID  
Sent By jwitmer Date 2012-09-11 Time 11:05 Rev Time 0.00
Received By jwitmer Date 2012-09-11 Time 11:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-08-02 Cont ID  
Sent By hmoser Date 2012-08-02 Time 14:39 Rev Time 0.00
Received By hmoser Date 2012-08-02 Time 14:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-09-11 Cont ID  
Sent By lwagner Date 2012-09-11 Time 12:29 Rev Time 0.00
Received By lwagner Date 2012-09-11 Time 12:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-07-23 Cont ID  
Sent By lwagner Date 2012-07-23 Time 14:59 Rev Time 0.00
Received By lwagner Date 2012-07-23 Time 14:00 Sent To  
Notes
2012-07-23 14:35:49FBC PLUMBING REVIEW #1
 DENIED:
  
 1. NO DRINKING FOUNTAIN WAS FOUND ON THE PLANS.
 BUSINESS OCCUPANCIES WITH OVER 15 OCCUPANTS REQUIRE
 DRINKING FOUNTAINS THAT MEET TABLE 403.1 AND THE
 FLORIDA ACCESSIBILITY CODE
 211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING
 FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN
 SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
 ***NOTE***:
 PLEASE SHOW LOCATION OF DRINKING FOUNTAIN IF ONE EXISTS
 ALREADY FOR THIS FLOOR.
  
 2. NO DETAIL WAS FOUND FOR THE LOUNGE SINK.
 FBC ACCESSIBILITY 602.2 CLEAR FLOOR SPACE COMPLYING
 WITH 305 & 306 OR EXCEPTION #1 SIDE APPROACH WITH SINK
 CENTERED A MINIMUM OF 24" FROM SIDE WALL IS REQUIRED.
 606.3 COUNTER TOP OR SINK RIM SHALL BE A MAXIMUM OF 34"
 ABOVE FINISHED FLOOR.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status N Date 2012-07-27 Cont ID  
Sent By aaponte Date 2012-07-27 Time 14:03 Rev Time 0.00
Received By aaponte Date 2012-07-27 Time 14:03 Sent To  
Notes
2012-07-27 14:15:25INTERIOR WORK ONLY.