Plan Review Details - Permit 12070371
Plan Review Stops For Permit 12070371
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-09-17 Cont ID  
Sent By rmcdouga Date 2012-09-17 Time 14:59 Rev Time 0.00
Received By rmcdouga Date 2012-09-17 Time 14:17 Sent To  
Notes
2012-09-17 15:03:12ACCORDING TO THE CITY'S FLOOD INSURANCE RATE MAP THE
 STRUCTURE IS LOCATED IN ZONE B. THE COUNTY GPS MAP
 INCORRECTLY SHOWS IT IN ZONE A.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-08-29 Cont ID  
Sent By rmcdouga Date 2012-08-29 Time 14:16 Rev Time 0.00
Received By rmcdouga Date 2012-08-29 Time 14:16 Sent To  
Notes
2012-08-29 14:17:392010 FBC
  
 DENIED BY BUILDING
  
 1) COMMENTS FROM FIRST REVIEW WERE NOT ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-08-14 Cont ID  
Sent By rmcdouga Date 2012-08-14 Time 10:56 Rev Time 0.00
Received By rmcdouga Date 2012-08-14 Time 10:56 Sent To  
Notes
2012-08-14 10:00:002010 FBC
  
 DENIED BY BUILDING
  
 1) THIS STRUCTURE IS LOCATED WITHIN 600 FEET OF THE
 INTER-COASTAL WATERWAY. ACCORDING TO FBCR 301.2.1.4.3,
 THE EXPOSURE CATEGORY FOR THIS PROJECT IS 'D'. PLEASE
 CORRECT.
  
 2) PLEASE REVISE THE COMPONENT AND CLADDING PRESSURES
 LISTED ON SHEETS A-1 AND A-3 TO BE CONSISTENT WITH
 EXPOSURE CATEGORY D. FBCR301.2.1
  
 3) THE STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA (SFHA), SPECIFICALLY AN A5 FLOOD ZONE. THE MINIMUM
 FINISH FLOOR HEIGHT REQUIRED BY THE CITY OF WPB FLOOD
 ORDINANCE IS 7.5' ABOVE BASE FLOOD ELEVATION (BFE).
 THIS INCLUDES THE 6" FREEBOARD THAT HAS BEEN ADOPTED BY
 THE CITY. PLEASE SPECIFY THE FINISH FLOOR ELEVATION ON
 THE PLANS AND SUBMIT AN ELEVATION CERTIFICATE FOR THE
 PROPOSED ENCLOSED FOYER ADDITION. WPB CITY ORDINANCES
 CHAPTER 94 ARTICLE XVII SEC. 94-541 THROUGH 94-547.
  
 4) THE SURVEY THAT WAS SUBMITTED INDICATES THAT THE
 STRUCTURE APPEARS TO LIE IN FLOOD ZONE "B" . HOWEVER,
 THE STRUCTURE IS LOCATED IN FLOOD ZONE "A5". PLEASE
 SUBMIT CORRECTED SURVEY. CITY AMENDMENTS 107.2.1
  
 5) SUBMIT TWO COPIES FOR PRODUCT APPROVALS FOR THE NEW
 DOOR, ROOF SHINGLES AND SIMPSON CONNECTORS AS REQUIRED
 BY DCA RULE 9N-3.
  
 6) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR
 THE PROJECT PER CITY AMENDMENTS 107.3.4.1.
  
 7) FBC R 403.1.4 REQUIRES ALL EXTERIOR FOOTINGS TO BE A
 MINIMUM OF 12" BELOW GRADE. SECTION 1 ON SHEET A-3
 INDICATES THE FOOTING 10" BELOW GRADE. PLEASE REVISE.
  
 8) SECTION 2 ON A-3 SHOWS THE 8" X 16" FOOTING WITH 2
 #5S, HOWEVER, IT IS MISLABELED AS THE 8" X 8" FOOTING
 W/1 #5. PLEASE CORRECT. CITY AMENDMENTS 107.2.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-07-23 Cont ID  
Sent By rlecky Date 2012-07-23 Time 13:56 Rev Time 0.00
Received By rlecky Date 2012-07-23 Time 12:56 Sent To  
Notes
2012-07-23 13:56:21NOTE THE FOLLOWING:
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT
 ALREADY EXIST WITHIN THE RESIDENCE. IF THE RESIDENCE
 HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE
 A CARBON MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET
 OF EACH ROOM USED FOR SLEEPING. 2012 FBC R314, 315
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-09-17 Cont ID  
Sent By rmcdouga Date 2012-09-17 Time 15:03 Rev Time 0.00
Received By rmcdouga Date 2012-09-12 Time 13:58 Sent To  
Notes
2012-09-12 13:59:01SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-08-29 Cont ID  
Sent By rmcdouga Date 2012-08-29 Time 14:17 Rev Time 0.00
Received By rmcdouga Date 2012-08-21 Time 18:11 Sent To  
Notes
2012-08-21 18:12:19GAVE TO MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-08-14 Cont ID  
Sent By rmcdouga Date 2012-08-14 Time 10:56 Rev Time 0.00
Received By rmcdouga Date 2012-07-12 Time 07:17 Sent To  
Notes
2012-07-12 07:18:05R12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-08-29 Cont ID  
Sent By rmcdouga Date 2012-08-29 Time 14:18 Rev Time 0.00
Received By rmcdouga Date 2012-08-29 Time 14:18 Sent To  
Notes
2012-08-29 14:18:59NO FEES WERE DUE. PLANS WERE STAMPED BY P.B. COUNTY.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-08-14 Cont ID  
Sent By rmcdouga Date 2012-08-14 Time 08:51 Rev Time 0.00
Received By rmcdouga Date 2012-08-14 Time 08:51 Sent To  
Notes
2012-08-14 08:54:17PLANS ARE REQUIRED TO BE REVIEWED BY PALM BEACH COUNTY
 FOR IMPACT FEES. THE STAMPED PLANS AND A COPY OF THE
 PAID RECEIPT IS REQUIRED BEFORE THE PERMIT IS ISSUED.

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-08-14 Cont ID  
Sent By rmcdouga Date 2012-08-14 Time 08:51 Rev Time 0.00
Received By rmcdouga Date 2012-08-14 Time 08:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2012-07-18 Cont ID  
Sent By eschneid Date 2012-07-18 Time 13:19 Rev Time 0.50
Received By eschneid Date 2012-07-18 Time 11:04 Sent To  
Notes
***NONE***