Plan Review Details - Permit 12070351
| Plan Review Stops For Permit 12070351 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-13 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-08-13 |
Time |
17:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-24 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-24 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2012-07-24 10:14:13 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. AN EDGE DISTANCE OF 2.25" REQUIRES A FACTOR OF .5 | | | APPLIED TO THE ANCHOR SPACING, SEE CHART ON SHEET 10. | | | | | | 2. CONNECTION TYPE PROPOSED NOT CLEAR. PLEASE REVISE TO | | | CORRESPOND WITH ANCHOR CHARTS; FOR INSTANCE, "9 TOP." | | | FOR INSTANCE, WALL MOUNT 9 WAS CIRCLED, THIS ANCHOR | | | SPACING CIRCLED (9 TOP AND 9 BOTTOM), BUT THIS COLUMN | | | STATES 1/2, BUT ONLY ONE DETAIL CIRCLED, APPEARS THAT | | | TWO DIFFERENT CONNECTION TYPES ARE PROPOSED (USE OF | | | 1/2), NOT CLEAR WHICH ONE IS PROPOSED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-14 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-14 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2012-07-14 13:57:06 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-13 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-27 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2012-07-30 15:28:36 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-24 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-19 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-14 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-12 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2012-07-12 08:51:53 | TO MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy