Plan Review Details - Permit 12070243
| Plan Review Stops For Permit 12070243 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-15 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-15 |
Time |
15:27 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-16 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-08-16 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2012-08-16 14:21:56 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. INCLUDE WIND SPEED ON PLAN, FBC RESIDENTIAL 301.2.1. | | | | | | 2. SOME ITEMS WERE OBSCURED WITH WHITE OUT. INCORPORATE | | | CHANGES INTO THE SIGNED AND SEALED PLAN, CANNOT ALTER | | | THE ENGINEER'S SPECIFICATION/DESIGN, FS471. | | | | | | 3. SHOW DIRECTION OF DRAINAGE ON THE SITE PLAN FBC | | | 401.3. | | | | | | 4. SHOW LOCATION OF ATTIC ACCESS, FBC R 807. | | | | | | 5. R802.1.6.3, THE "WALL BRACING GABLE END" DOES NOT | | | SHOW ANY LATERAL SUPPORT, NOT CLEAR HOW THIS DETAIL | | | PROVIDES THE SUPPORT REQUIRED TO RESIST WIND LOADS AND | | | TO PROVIDE BRACING REQUIRED BY FBC RESIDENTIAL 609.4. | | | | | | 6. REVISE "WALL BRACING GABLE END" DETAIL TO INCLUDE | | | GABLE OVERHANG, FBC R 609.4. | | | | | | 7. FBC R 703.6.3, BOND BREAK REQUIRED FOR STUCCO. | | | | | | 8. FBC R 704 EXCEPTION 1, 5/8" STUCCO TOO THICK; REVISE | | | WALL DETAIL TO PROVIDE FOR INSPECTION FOR TERMITES. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-10-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-10-23 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-10-23 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-10-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-10-23 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-09-19 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2012-10-15 15:41:30 | 10/15 TO ELEC BOX | | | | | 2012-09-19 15:28:08 | SENT TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-16 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-16 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2012-07-17 11:21:21 | SENT TO ZONING BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2012-09-25 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2012-09-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2012-09-19 |
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2012-07-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2012-07-17 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2012-07-23 08:22:55 | ROUTED TO MISC. 2 BOX | | | | | | 7/23/12 ZONING FAILED - SEC. 94-304. - ACCESSORY | | | STRUCTURES | | | ACCESSORY STRUCTURES IN RESIDENTIAL DISTRICTS. | | | B.(1) MAXIMUM SQUARE FOOTAGE. THE TOTAL FLOOR AREA OF | | | ALL ROOFED ACCESSORY BUILDINGS ON A PROPERTY SHALL NOT | | | EXCEED 75 PERCENT OF THE GROSS FLOOR AREA OF THE | | | PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF 1,000 | | | SQUARE FEET. | | | | | | |
|
|
|