Plan Review Details - Permit 12070227
| Plan Review Stops For Permit 12070227 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2013-08-01 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-01 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-01 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2013-08-01 16:42:05 | LETTER PROVIDED IS UNACCEPTABLE AND IN DIRECT CONFLICT | | | WITH NEC FOR OCCUPANT TO HAVE ACCESS TO THEIR | | | OVERCURRENT DEVICES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-09-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-09-17 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-09-17 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-07-13 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-07-13 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-07-13 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2012-07-13 13:34:54 | 12070227 | | | 219 CLEMATIS ST. | | | ELECTRIC SERVICE MODIFICATION | | | | | | PLEASE HAVE THE ELECTRICAL ENGINEER ADDRESS THE | | | FOLLOWING REVIEW COMMENTS. PLEASE CALL IF THERE ARE ANY | | | QUESTIONS: | | | | | | ELECTRICAL DESIGN FOR SERVICE EQUIPMENT RATED AT 1200 | | | AMPERES REQUIRES A FLORIDA REGISTERED ENGINEER. 2010 | | | FBC 105.3.1.2 (5), FS CHAPTER 471.003 (2) (H) 2.A | | | | | | VERIFY THE ELECTRICAL SERVICE MAINS FOR THIS BUILDING | | | ARE SIX OR LESS AND GROUPED IN ONE LOCATION. | | | NEC 230.2, 230.71, 230.72 | | | | | | INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE | | | NEW SERVICE, SWITCH GEAR AND ELECTRIC PANELS. NEC | | | 110.9, 110.10 | | | | | | PROVIDE A DETAIL SHOWING THAT THE REQUIRED WORKING | | | CLEARANCES AND DEDICATED WORKING SPACE HAS BEEN | | | PROVIDED FOR THE ELECTRICAL EQUIPMENT AND PANEL BOARDS. | | | NEC 110.26, 240.24, 408.17 | | | | | | PROVIDE A SUMMARY LOAD CALCULATION. NEC 230.31 | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-09-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-09-17 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-09-12 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2012-09-13 09:07:07 | SENT TO ELECTRIC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-07-13 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-07-13 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-07-09 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2012-07-10 07:38:29 | SENT TO ELECT UNDER $5 K BOX |
|
|
|