Plan Review Details - Permit 12070026
| Plan Review Stops For Permit 12070026 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-24 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-24 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2012-07-24 10:27:38 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PLEASE REVISE DESCRIPTION, "BOAT STEEL METAL | | | BUILDING," IS THIS FOR BOAT STORAGE OR IS "BOAT STEEL" | | | THE MATERIAL PROPOSED? | | | | | | 2. PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPROVAL FOR | | | THE ROOF PANELS, FAC9N-3. | | | | | | 3. ENGINEERING REQUIRES THE FOLLOWING: | | | | | | TO BE SIGNED, SEALED, DATED ORGINALS FS 471 | | | CERTIFICATE OF AUTHORIZATION FOR THE ENGINEERING | | | COMPANY A & A ENGINEERING TO BE INCLUDED ON THE TITLE | | | BLOCK, FAC61G15-23.002 (CONTACT FBPE FOR MORE | | | INFORMATION) | | | REVISE TO INCLUDE DESIGN CRITERIA FBC RESIDENTIAL 301.1 | | | - THIS APPEARS TO BE DESIGNED TO ASCE7-05, WHICH IS | | | OUTDATED. | | | PROVIDE A SITE SPECIFIC (OR CIRCLE OPTIONS PROPOSED) | | | WHICH SHOWS SPECIFIC WIND DESIGN CRITERIA, AND DESIGN | | | OPTIONS SPECIFIC TO THIS PROJECT. ENGINEERING PROVIDED | | | IS GENERIC | | | | | | | | | | | | | | 2012-07-03 09:33:09 | INCOMING SENT TO ZONING BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-24 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-03 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2012-07-03 09:30:03 | INCOMING SENT TO MISC BOX # 1. JW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2012-07-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2012-07-09 |
Time |
14:13 |
Sent To |
B |
|
| Notes |
| 2012-07-11 09:27:15 | THE APPLICANT MUST REVISE THE PROPOSAL AND DEMONSTRATE | | | COMPLIANCE WITH THE FOLLOWING CODE REQUIREMENTS. PLEASE | | | CONTACT PLANNER, MURRIAH DEKLE @561.822.1442 WITH ANY | | | QUESTIONS. | | | | | | SEC. 94-304. - ACCESSORY STRUCTURES. | | | | | | (1)MAXIMUM SQUARE FOOTAGE. THE TOTAL FLOOR AREA OF ALL | | | ROOFED ACCESSORY BUILDINGS ON A PROPERTY SHALL NOT | | | EXCEED 75 PERCENT OF THE GROSS FLOOR AREA OF THE | | | PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF 1,000 | | | SQUARE FEET. | | | | | | (2) | | | SETBACKS. | | | FRONT: 25 FEET. | | | SIDE: FIVE FEET FROM THE LOT LINES. | | | CORNER: SAME AS REQUIRED FOR PRINCIPAL STRUCTURE. | | | REAR: FIVE FEET MINIMUM OR 15 FEET FROM THE CENTERLINE | | | OF THE ALLEY TO A GARAGE DOOR FACING THE ALLEY, | | | WHICHEVER IS GREATER. | | | | | | (3)BUILDING SEPARATION. ACCESSORY STRUCTURES COVERED | | | WITH A SOLID ROOF SHALL BE LOCATED NO CLOSER THAN SIX | | | FEET TO THE PRINCIPAL STRUCTURE. ACCESSORY STRUCTURES | | | LESS THAN SIX FEET FROM THE PRIMARY STRUCTURE MUST MEET | | | THE PRIMARY STRUCTURE SETBACKS. ACCESSORY STRUCTURES | | | MAY BE CONNECTED TO THE PRINCIPAL STRUCTURE WITH A | | | CANVAS COVERED OPEN BREEZEWAY. | | | |
|
|
|