Plan Review Details - Permit 12060874
| Plan Review Stops For Permit 12060874 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-13 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-08-13 |
Time |
17:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-24 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-24 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2012-07-24 09:26:24 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PLEASE SEE ANCHOR SCHEDULES ON SHEET 7. BASED ON THE | | | DETAILS CIRCLED AND THE INSTALLATION SCHEDULE PROVIDED, | | | IT APPEARS THAT BY CONNECTION TYPE "1" YOU PROPOSE TO | | | USE C3 (SEE DETAIL ON SHEET 4) AND FOR "11", C4 IS | | | PROPOSED. | | | | | | FOR -66.5PSF DESIGN PRESSURE, YOU MUST USE THE 73PSF | | | ROW. C1, 57PSF SPACING OF 12" WAS CIRCLED AND INDICATED | | | ON THE INSTALLATION SCHEDULE. HOWEVER, BASED ON THE | | | DETAILS CIRCLED, THIS IS NOT THE CORRECT CONNECTION | | | TYPE. | | | | | | 12" IS OK FOR C3 UP TO 6", BUT SPANS OVER 6' REQUIRE | | | TIGHTER SPACING, SEE ANCHOR SCHEDULES. | | | | | | C4, 73PSF, 12" SPACING DOES NOT COMPLY; 8.5" REQUIRED | | | FOR SPAN UP TO 6'. | | | | | | PLEASE REVISE INSTALLATION SCHEDULE ACCORDINGLY TO SHOW | | | COMPLIANCE WITH FBC 301.1, RESISTANCE TO WIND LOADS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-05 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-05 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2012-07-05 15:48:55 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-13 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-27 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2012-07-30 14:38:47 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-24 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-19 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-05 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-06-29 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2012-06-29 09:38:49 | TO MISC 1 | | | |
|
|
|