Plan Review Details - Permit 12060801
Plan Review Stops For Permit 12060801
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-07-11 Cont ID  
Sent By jwitmer Date 2012-07-11 Time 14:02 Rev Time 0.00
Received By jwitmer Date 2012-07-11 Time 14:00 Sent To  
Notes
2012-07-11 14:08:17 
  
 BUILDING PLAN REVIEW
 PERMIT: 12060801
 ADD: 2480 PRESIDENTIAL WAY # 1002
 CONT: TYCON CONSTRUCTION
 TEL: (561)756-1409
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 BUILDING PROVISO:
 PLANS DO NOT INDICATE THE REMOVAL OF FLOORING, IF FLOOR
 COVERINGS ARE TO BE REMOVED THEN COMPLIANCE WITH :
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1A) 2010 FBC-B 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B)2010 FBC-B 603.1 ALLOWABLE MATERIALS. COMBUSTIBLE
 MATERIALS SHALL BE PERMITTED IN BUILDINGS OF TYPE I OR
 TYPE II CONSTRUCTION IN THE FOLLOWING APPLICATIONS AND
 IN ACCORDANCE WITH SECTIONS 603.1.1 THROUGH 603.1.3:
 603.1.3.2 EXCEPTIONS:
 1 INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
 2. INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND
 SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE
 ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
 200.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-07-02 Cont ID  
Sent By rlecky Date 2012-07-02 Time 12:20 Rev Time 0.00
Received By rlecky Date 2012-07-02 Time 12:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-07-11 Cont ID  
Sent By jwitmer Date 2012-07-11 Time 14:08 Rev Time 0.00
Received By jwitmer Date 2012-06-27 Time 09:51 Sent To  
Notes
2012-06-28 09:51:40SENT TO B4 SHELF FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-06-29 Cont ID  
Sent By lwagner Date 2012-06-29 Time 14:25 Rev Time 0.00
Received By lwagner Date 2012-06-29 Time 14:20 Sent To  
Notes
***NONE***