Plan Review Details - Permit 12060751
Plan Review Stops For Permit 12060751
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2013-02-28 Cont ID  
Sent By jwitmer Date 2013-02-28 Time 15:11 Rev Time 0.00
Received By jwitmer Date 2013-02-28 Time 15:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2013-02-22 Cont ID  
Sent By jwitmer Date 2013-02-22 Time 10:08 Rev Time 0.00
Received By jwitmer Date 2013-02-22 Time 10:07 Sent To  
Notes
2013-02-22 10:08:46BUILDING PLAN REVIEW
 PERMIT: 12060751
 ADD: 2020 CHAGAL CIR
 CONT: ARMENTI CONST. & ACCESS SYST.
 TEL: (561)386-6826
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 ACTION: DENIED
  
 1) SEE FIRE COMMENT.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-12-26 Cont ID  
Sent By jwitmer Date 2012-12-26 Time 10:45 Rev Time 0.00
Received By jwitmer Date 2012-12-26 Time 10:37 Sent To  
Notes
2012-12-26 10:45:17BUILDING PLAN REVIEW
 PERMIT: 12060751
 ADD: 2020 CHAGAL CIR
 CONT: ARMENTI CONST. & ACCESS SYST.
 TEL: (561)386-6826
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 ACTION: DENIED
  
 1) COMPLIED.
 NEW COMMENTS: SHOW COMPLIANCE WITH NEW 2010 CODE
 SECTIONS :
 1A) 3110.3 VEHICULAR GATES INTENDED FOR AUTOMATION.
 VEHICULAR GATES INTENDED FOR AUTOMATION SHALL BE
 DESIGNED, CONSTRUCTED AND INSTALLED TO COMPLY WITH THE
 REQUIREMENTS OF ASTM F 2200.
  
 1B) 3110.4 VEHICULAR GATE OPENERS.
 VEHICULAR GATE OPENERS, WHEN PROVIDED, SHALL BE LISTED
 IN ACCORDANCE WITH UL 325.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-07-11 Cont ID  
Sent By jwitmer Date 2012-07-11 Time 13:03 Rev Time 0.00
Received By jwitmer Date 2012-07-11 Time 13:03 Sent To  
Notes
2012-07-11 13:07:18BUILDING PLAN REVIEW
 PERMIT: 12060751
 ADD: 2020 CHAGAL CIR
 CONT: ARMENTI CONST. & ACCESS SYST.
 TEL: (561)386-6826
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET A2 INDICATES THE WIND DESIGN TO BE 140 MPH/ 3
 SECOND GUST, PLEASE SEE 2010 FBC-B ADOPTION DATE OF
 03/15/12 AND NEW V U WIND DESIGN CRITERIA,
  
  
 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE
 TABLE 1609.2(2) .
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-07-02 Cont ID  
Sent By rlecky Date 2012-07-02 Time 12:09 Rev Time 0.00
Received By rlecky Date 2012-07-02 Time 12:03 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2012-07-23 Cont ID  
Sent By mgonzale Date 2012-07-23 Time   Rev Time 0.25
Received By mgonzale Date 2012-07-23 Time   Sent To  
Notes
2012-07-23 12:15:21CITY OF WPB WATERMAIN IN THE VICINITY
 CALL 811 BEFORE DIGG.
 ANY NEW FENCE PANEL / PANE MUST BE REMOVABLE OVER
 WATERMAIN AREA.
  
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2013-02-27 Cont ID  
Sent By wjolin Date 2013-02-27 Time 11:38 Rev Time 0.00
Received By wjolin Date 2013-02-27 Time 11:38 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2013-02-19 Cont ID  
Sent By eschneid Date 2013-02-21 Time 16:40 Rev Time 0.00
Received By wjolin Date 2013-02-19 Time 11:01 Sent To Z
Notes
2013-02-19 11:14:142020 CHAGALL CIRCLE
 PERMIT #12060751
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 REPEAT COMMENT (X2): NO ADDRESS PROVIDED ON THE PLANS.
  
 NEW COMMENT: PLANS INDICATE KNOXBOX KEY SWITCH WILL
 OPEN GATES FOR EMERGENCY RESPONDERS. PLEASE INDICATE
 HOW THE LIFTMASTER ARMS WILL OPERATED BY EMERGENCY
 RESPONDERS.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2013-01-10 Cont ID  
Sent By wjolin Date 2013-01-10 Time 13:41 Rev Time 0.00
Received By wjolin Date 2013-01-10 Time 13:40 Sent To  
Notes
2013-01-10 13:41:242020 CHAGALL CIRCLE
 PERMIT #12060751
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 REPEAT COMMENT: NO ADDRESS PROVIDED ON THE PLANS.
  
 REPEAT COMMENT: FIRE DEPARTMENT ACCESS REQUIRES AN
 UNOBSTRUCTED WIDTH OF 20 FEET. THE INCOMING TRAFFIC
 LANES SHOW A MEDIAN/CURB/DIVIDER.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-07-02 Cont ID  
Sent By wjolin Date 2012-07-02 Time 10:37 Rev Time 0.00
Received By wjolin Date 2012-07-02 Time 10:17 Sent To ENG
Notes
2012-07-02 10:37:122020 CHAGALL CIRCLE
 PERMIT #12060751
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NO ADDRESS PROVIDED ON THE PLANS.
  
 THE TRAFFIC SPIKES INDICATE A MAXIMUM VEHICLE WEIGHT OF
 8,000 POUNDS; HOWEVER, SOME CITY FIRE RESCUE APPARATUS
 WEIGH IN EXCESS OF 64,000 POUNDS.
  
 FIRE DEPARTMENT ACCESS REQUIRES AN UNOBSTRUCTED WIDTH
 OF 20 FEET. THE INCOMING TRAFFIC LANES SHOW A
 MEDIAN/CURB/DIVIDER.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2013-02-28 Cont ID  
Sent By jwitmer Date 2013-02-28 Time 15:11 Rev Time 0.00
Received By jwitmer Date 2013-02-26 Time 12:48 Sent To  
Notes
2013-02-28 08:02:022/28 TO JW DESK
  
2013-02-26 12:48:45TO FIRE

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2013-02-22 Cont ID  
Sent By jwitmer Date 2013-02-22 Time 10:08 Rev Time 0.00
Received By jwitmer Date 2013-02-13 Time 16:45 Sent To  
Notes
2013-02-13 16:46:31ADDITIONAL EASEMENT RELEASE FORMS SUBMITTED. SENT TO
 FIRE SHELF ALONG WITH PACKAGE SUBMITTED ON 2/7/13. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-02-22 Cont ID  
Sent By jwitmer Date 2013-02-22 Time 10:08 Rev Time 0.00
Received By jwitmer Date 2013-02-07 Time 14:08 Sent To  
Notes
2013-02-08 14:11:45IN FIRE BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-10 Cont ID  
Sent By wjolin Date 2013-01-10 Time 13:41 Rev Time 0.00
Received By wjolin Date 2012-12-20 Time 10:15 Sent To  
Notes
2012-12-21 10:21:12B--5

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-07-24 Cont ID  
Sent By rmcdouga Date 2012-07-24 Time 15:51 Rev Time 0.00
Received By rmcdouga Date 2012-06-26 Time 16:35 Sent To  
Notes
2012-06-26 16:35:35B--9

Review Stop Z ZONING
Rev No 3 Status P Date 2013-02-20 Cont ID  
Sent By eschneid Date 2013-02-20 Time 19:18 Rev Time 0.45
Received By eschneid Date 2013-02-20 Time   Sent To B
Notes
2013-02-20 19:32:10PASSED W/PROVISO
  
 1) 6 FOOT HIGH FENCE REQUIRES 40 FOOT SETBACK FROM
 RIGHT-OF-WAY.
  
 2) FENCE TOP SPEAR ELEMENTS SHALL BE BLUNTED.
2013-02-20 09:17:28GAVE TO E.S. - MD

Review Stop Z ZONING
Rev No 2 Status F Date 2013-01-07 Cont ID  
Sent By eschneid Date 2013-01-07 Time 15:58 Rev Time 1.00
Received By eschneid Date 2013-01-07 Time 15:58 Sent To  
Notes
2013-01-07 15:58:44FAILED
  
 1) THE MODIFICATION FOR THE ADDITIONAL GATES AND
 FENCING REQUIRES THE APPROVAL OF THE SUBMITTED MINOR
 PLANNED DEVELOPMENT AMENDMENT PRIOR TO ZONING APPROVAL
 OF THIS PERMIT APPLICATION.
  
 2) THE MINOR AMENDMENT IS NOT APPROVABLE SINCE THE
 WESTERN PORTION OF THE FENCE IS SHOWN AT 6 FEET TALL
 WITHIN THE REQUIRED FRONT SETBACK.
  
 3) IF NOT FOR THE IMPROPER FENCE LOCATION ON THE SITE
 PLAN, THIS PERMIT WOULD BE APPROVED BY ZONING.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2013-01-02 16:06:501/2/13

Review Stop Z ZONING
Rev No 1 Status F Date 2012-07-17 Cont ID  
Sent By eschneid Date 2012-07-17 Time 15:46 Rev Time 0.75
Received By eschneid Date 2012-07-17 Time 15:46 Sent To FIRE
Notes
2012-07-17 16:12:53FAILED
  
 PLEASE RESPOND TO COMMENTS IN WRITING.
  
 1) THE MODIFICATION FOR THE ADDITIONAL GATES, FENCING
 AND TIRE SPIKES REQUIRES THE APPROVAL OF A MINOR
 PLANNED DEVELOPMENT AMENDMENT PRIOR TO ZONING APPROVAL
 OF THIS PERMIT APPLICATION. THE MINOR PLANNED
 DEVELOPMENT APPLICATION IS AVAILABLE FROM THE CITY'S
 PLANNING DIVISION. PLEASE NOTE THAT SINCE A PORTION OF
 THE SITE IS ON LAND WITHIN THE BEAR LAKES COUNTY CLUB
 PLANNED DEVELOPMENT, TWO APPLICATIONS ARE REQUIRED.
  
 2) PROVIDE TWO COPIES OF A RECENT SURVEY, LESS THAN ONE
 YEAR OLD, SHOWING THE PROPERTY LINES, THE DRIVEWAYS,
 THE EXISTING WALLS, GATES AND RELATED FEATURES.
 DIMENSIONS SHALL BE PROVIDED FOR ALL FEATURES. THE
 SURVEY ONLY NEEDS TO INCLUDE THE LIMITS OF WORK AND NOT
 THE ENTIRE DEVELOPMENT.
  
 3) THE PLANNED DEVELOPMENT DISTRICT ESTABLISHES THAT
 THERE IS A 20 FOOT FRONT SETBACK FROM THE SHENANDOAH
 RIGHT-OF-WAY; THEREFORE, THE FENCE MAY NOT EXCEED FOUR
 (4) FEET IN HEIGHT WITHIN THIS SETBACK. THE FENCE IS
 DESCRIBED AS SIX (6) FEET IN HEIGHT ON THE PERMIT
 APPLICATION, YET NO DIMENSIONS ARE PROVIDED ON THE
 FENCE DETAILS.
  
 4) THE PLANS SHALL CLEARLY INDICATE THAT THE "SPEAR
 POINTS" ARE BLUNT.
  
 5) THE PLANS STATE THAT NO LANDSCAPE ALTERATIONS ARE
 PROPOSED, YET A COMPARISON OF THE PLANS AND THE GOGGLE
 STREET VIEW SHOW THE GATE ARM SUPPORTS BEING PLACED
 INTO EXISTING LANDSCAPE AREAS THAT CONTAIN
 HEDGES/GROUND COVER.
  
 6) THE PLANS INCLUDE THREE DIFFERENT PARCELS - THE
 RIGHT-OF-WAY AND COMMON AREA PARCELS OWNED BY CLASSICS
 AT BEAR LAKES HOA INC. AND THE CANAL PARCEL OWNED BY
 BEAR LAKES COUNTRY CLUB INC. A SEPARATE PERMIT
 APPLICATION NEEDS TO BE FILED FOR EACH PARCEL. PLEASE
 NOTE THAT THE BEAR LAKES COUNTRY CLUB INC. NEEDS TO
 PROVIDE PROOF THAT THEY WILL PERMIT THE FENCE TO BE
 BUILT ON THEIR PROPERTY.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved