| 2012-07-12 11:53:57 | BUILDING PLAN REVIEW |
| | PERMIT: 12060693 |
| | ADD: 1201 ALLENDALE RD |
| | CONT: TIM JOHNSON REMODELING |
| | TEL: (561)707-7058 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) 2010 FBC/ B WPB ADMINISTRTIVE CODE107.3.5 MINIMUM |
| | PLAN REVIEW CRITERIA FOR BUILDINGS |
| | 107.3.5.1 COMMERCIAL BUILDINGS: |
| | 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS |
| | SHALL BE DETERMINED. WHAT TYPE OF OCCUPANCY WILL THE |
| | MEZZANINE BE USED FOR? |
| | 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| | OCCUPANCY LOAD |
| | GROSS |
| | NET |
| | MEANS OF EGRESS |
| | EMERGENCY LIGHTING AND EXIT SIGNS |
| | 8. STRUCTURAL REQUIREMENTS SHALL INCLUDE: |
| | STRUCTURAL CALCULATIONS (IF REQUIRED) |
| | 10. ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE |
| | FOLLOWING: |
| | ACCESSIBLE ROUTE |
| | VERTICAL ACCESSIBILITY IF THE MEZZANINE LEVEL IS USED |
| | FOR OTHER THAN STORAGE. |
| | 11. INTERIOR REQUIREMENTS SHALL INCLUDE THE FOLLOWING: |
| | INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT) |
| | LIGHT AND VENTILATION |
| | |
| | 2) POSTING OF THE FLOOR LOAD OF THE MEZZANINE PER WPB |
| | ADMINISTRATIVE CODE.106.1 LIVE LOADS POSTED. WHERE THE |
| | LIVE LOADS FOR WHICH EACH FLOOR OR PORTION THEREOF OF A |
| | COMMERCIAL OR INDUSTRIAL BUILDING IS OR HAS BEEN |
| | DESIGNED TO EXCEED 50 PSF (2.40 KN/M2), SUCH DESIGN |
| | LIVE LOADS SHALL BE CONSPICUOUSLY POSTED BY THE OWNER |
| | IN THAT PART OF EACH STORY IN WHICH THEY APPLY, USING |
| | DURABLE SIGNS. IT SHALL BE UNLAWFUL TO REMOVE OR DEFACE |
| | SUCH NOTICES. |
| | |
| | 3) THE PLANS DO NOT INDICATE TO WHAT LIVE LOAD THEY |
| | WERE DESIGNED PLEASE REVIEW 2010FBC-B TABLE 1607.1. |
| | (35) 100 LBS. |
| | |
| | 4) PLANS INDICATE THEY ARE DESIGNED TO THE 2007FBC-B, |
| | MARCH 15/2012 THE 2010 FBC-B WAS ADOPTED STATE WIDE THE |
| | WIND DESIGN ASCE 7-10, WE ARE LOCATED IN A 170 MPHWIND |
| | ZONE FOR CATEGORY II BUILDINGS. |
| | |