Plan Review Details - Permit 12060531
Plan Review Stops For Permit 12060531
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-10-09 Cont ID  
Sent By shill Date 2012-10-09 Time 16:55 Rev Time 0.00
Received By shill Date 2012-10-09 Time 16:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-08-03 Cont ID  
Sent By shill Date 2012-08-03 Time 16:02 Rev Time 0.00
Received By shill Date 2012-07-31 Time 07:42 Sent To  
Notes
2012-08-03 18:14:54****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 DISCUSSED WITH ARCHITECT THE FOLLOWING ISSUES:
  
 1. BASED ON SQUARE FOOT AREA PROVIDED AND FBC TABLE
 1004, OCCUPANT LOAD WILL BE OVER 50 (6870 / 30 = 229).
 DOORS IN THE MEANS OF EGRESS ARE TO SWING IN THE
 DIRECTION OF TRAVEL, BUT AS DISCUSSED EXISTING BUILDING
 CODE 101.5 EXCEPTION ALLOWS USE OF CODE IN EFFECT WHEN
 THE BUILDING WAS BUILT WITH APPROVAL FROM THE BUILDING
 OFFICIAL.
  
 IT APPEARS FROM THE SURVEY THAT THE DIXIE HIGHWAY DOOR
 CAN SWING OUT AND WILL NOT ENCROACH INTO THE PUBLIC
 WAY; PLEASE VERIFY, AND AS DISCUSSED, PLEASE
 INVESTIGATE THE POSSIBILITY THAT THIS DOOR CAN SWING
 OUT.
  
 THE FLAMINGO DRIVE SIDE OF THE BUILDING IS ON THE
 PROPERTY LINE, SO THIS DOOR WOULD NEED TO EITHER HAVE A
 VESTIBULE, SWING OUT ENTIRELY OVER THE PROPERTY LINE
 AND FULL ENCROACHMENT INTO THE PUBLIC WAY, OR SWING IN.
 THE PROPOSED IRON GRILLS ARE SHOWN SWINGING OUT OVER
 THE PROPERTY LINE.
  
 IN THE 1929 BUILDING CODE, SECTION 46 INCLUDES SOME
 PROVISION FOR ENCROACHING THE PROPERTY LINE WITH DOORS
 WHICH ARE NORMALLY IN THE CLOSED POSITION, BUT ONLY IN
 FIRE DISTRICTS 3 AND 4, BUT NOT IN 1 AND 2. IT WOULD
 REQUIRE FURTHER INVESTIGATION TO DETERMINE WHICH FIRE
 DISTRICT THIS PROPERTY WAS IN AT THAT TIME.
  
 AS DISCUSSED, THE PRIMARY ENTRANCE AND EXIT DOOR WILL
 BE THE REAR DOOR, AND THE AREA ADJACENT TO THIS DOOR
 WILL NOT BE USED FOR STORAGE AS THIS IS THE DOOR
 LEADING FROM THE PARKING AREA DIRECTLY TO THE BUILDING.
  
 AS DISCUSSED, PLEASE SUBMIT AN EMAIL WHICH OUTLINES
 PROPOSED EXITING STRATEGY, PROPOSED DOOR SWING, AND
 EXISTING CONDITIONS TO SUPPORT YOUR REQUEST TO EITHER
 HAVE INSWING DOORS, OUTSWING DOOR OR GRILL ENCROACHING
 PROPERTY LINE. THIS WILL BE DISCUSSED WITH THE ABO.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-07-06 Cont ID  
Sent By shill Date 2012-07-06 Time 15:15 Rev Time 0.00
Received By shill Date 2012-07-06 Time 15:15 Sent To  
Notes
2012-07-06 15:38:32****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 COMPONENTS & CLADDING (DOORS, WINDOWS), 9N-3.
  
 2. DOOR & WINDOW DATA, SHEET A01, REFERS TO THE
 RESIDENTIAL CODE. FBC 2010 BUILDING SHOULD BE USED FOR
 THIS COMMERCIAL BUILDING, PLEASE REVISE.
  
 3. DOOR & WINDOW DATA REFERS TO 2ND FLOOR DOORS, PLEASE
 REMOVE NOTE OR PROVIDE PLAN FOR 2ND FLOOR WORK.
  
 4. PROVIDE A LIFE SAFETY PLAN WHICH SHOWS TRAVEL
 DISTANCE, OCCUPANT LOAD, OCCUPANCY CLASSIFICATION FBC
 1004 FOR EACH AREA, ROOM DESIGNATIONS FOR ALL AREAS.
 NOT ENOUGH INFORMATION PROVIDED TO GIVE A COMPLETE
 COMMENT LIST AS OCCUPANT LOAD IS REQUIRED IN ORDER TO
 DETERMINE DOOR SWING REQUIREMENTS, ELIMINATION OF EXIT
 DOOR. BUILDING PLANS ON FILE SHOW A RECESSED OUTSWING
 DOOR IN THESE LOCATIONS. FBC 1008.1.2.
  
 5. PROVIDE A STRUCTURAL DETAIL FOR THE PROPOSED SILL,
 FBC 106, FBC 1609.
  
 6. IF OUTSWING DOORS ARE PROPOSED, PROVIDE A SITE
 PLAN/SURVEY SHOWING ENCROACHMENT OVER PROPERTY LINE,
 FBC 3202.2.
  
 7. SEE FBC 2010 EXISTING BUILDING 101.5 AND SELECT
 METHOD OF COMPLIANCE.
  
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2012-09-28 Cont ID  
Sent By fmittner Date 2012-09-28 Time 09:56 Rev Time 0.00
Received By fmittner Date 2012-09-28 Time 09:56 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2012-07-19 Cont ID  
Sent By fmittner Date 2012-07-19 Time 09:38 Rev Time 0.00
Received By fmittner Date 2012-07-19 Time 09:38 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2012-06-19 Cont ID  
Sent By aaponte Date 2012-06-19 Time 14:16 Rev Time 0.00
Received By fmittner Date 2012-06-19 Time 14:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-08-03 Cont ID  
Sent By shill Date 2012-08-03 Time 18:15 Rev Time 0.00
Received By shill Date 2012-07-19 Time 11:18 Sent To  
Notes
2012-07-23 11:19:21SENT TO SAMANTHA'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-07-06 Cont ID  
Sent By shill Date 2012-07-06 Time 15:38 Rev Time 0.00
Received By shill Date 2012-06-19 Time 10:47 Sent To  
Notes
2012-06-20 10:47:51MISC #1