| 2012-10-31 15:36:34 | BUILDING PLAN REVIEW |
| | PERMIT:12060374 |
| | ADD: 2101 PALM BEACH LAKES |
| | CONT: MILLER |
| | TEL: (954)605-2193 |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | OCT. 31 /2012 |
| | ACTION: DENIED |
| | |
| | 1) A RESIDENT INSPECTOR WILL BE REQUIRED FOR THIS |
| | PROJECT PER WEST PALM BEACH ADMINISTRATIVE CODE |
| | SECTION: |
| | 110.3.9 OTHER INSPECTIONS SERVICES. THE BUILDING |
| | OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE |
| | INSPECTIONS REQUIRED BY SECTION 109. HE/SHE MAY ACCEPT |
| | REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION |
| | SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS |
| | SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A |
| | CERTIFICATE CALLED FOR BY ANY PROVISION OF THE |
| | TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS |
| | UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A |
| | RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING |
| | OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION |
| | SERVICE IN THE FOLLOWING INSTANCES: |
| | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II |
| | CONSTRUCTION |
| | 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS |
| | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE |
| | STRENGTH (F ?C) IN EXCESS OF 3000 POUNDS PER SQUARE |
| | INCH |
| | 4. FOR PILE DRIVING |
| | 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE |
| | FOOT |
| | 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT |
| | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR |
| | METHODS OF CONSTRUCTION |
| | SUCH INSPECTORS SHALL BE ADEQUATELY PRESENT AT TIMES |
| | WORK IS UNDERWAY ON THE STRUCTURAL ELEMENTS OF THE |
| | BUILDING. SUCH INSPECTORS SHALL BE A REGISTERED |
| | ARCHITECT, OR ENGINEER, OR A PERSON LICENSED UNDER |
| | CHAPTER 468, PART XII, FLORIDA STATUTES. SUCH |
| | INSPECTORS SHALL SUBMIT WEEKLY PROGRESS REPORTS |
| | INCLUDING THE DAILY INSPECTIONS TO THE BUILDING |
| | OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF |
| | THE RESIDENT INSPECTOR. |
| | CONTACT KEN CONRAD MANAGER OF THE RESIDENT INSPECTOR |
| | PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION |
| | BEFORE THE PERMIT MAY BE ISSUED. |
| | |
| | 2-5) COMPLIED. |
| | |
| | 6) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 7) FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 8) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 |
| | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR |
| | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS/ MULLIONS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS, INSULATIONS AND ASSEMBLIES |
| | (G) PRE-ENGINEERED A/C STANDS |
| | |
| | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | NEW COMMENT!!!!!! |
| | |
| | 10 ) FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF |
| | ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN |
| | "A8" FLOOD ZONE, ELEVATION FINISHED FLOOR MUST BE 16.5' |
| | NGVD. PLEASE PROVIDE THE SLAB ELEVATION OF EXISTING |
| | SLAB AND NEW PROPOSED SLAB. IF THE EXISTING SLAB IS |
| | BELOW THE 16.5' ELEVATION NGVD, THEN SUBSTANTIAL |
| | IMPROVEMENT REQUIREMENTS WILL NEED TO BE REVIEWED, |
| | PLEASE SEE CITY WPB MUNI-CODE 94-546 FOR |
| | NON-RESIDENTIAL CONSTRUCTION AND REQUIREMENTS FOR FLOOD |
| | MITIGATION. A FLOOD ELEVATION CERTIFICATE WILL BE |
| | REQUIRED BEFORE ISSUANCE OF PERMIT FOR THE EXISTING |
| | SLAB AND PROPOSED NEW SLAB. A SECOND WILL BE REQUIRED |
| | AFTER THE NEW SLAB IS POURED AND A THIRD BEFORE THE |
| | CERTIFICATE OF OCCUPANCY CAN OCCUR. |
| | |
| | 11/07/12 E-MAIL SENT : |
| | |
| | |
| | WEST PALM BEACH DEVELOPMENT SERVICES/ BUILDING DIVISION |
| | PERMIT: 12060374 |
| | ADDRESS 2101 PALM BEACH LAKES BLVD. |
| | ASHLEY FURNITURE |
| | NOV. 07/ 2012 |
| | |
| | GOOD MORNING MS MENENDEZ, |
| | |
| | WE HAVE REVIEWED THE FLOOD ZONE CERTIFICATE ATTACHED |
| | AND FOUND THAT IT IS NOT IN COMPLIANCE WITH THE FLOOD |
| | ZONE PROVISIONS AND CAN NOT BE ACCEPTED. THE |
| | CERTIFICATE DOES INDICATE THAT THE FINISH FLOOR SLAB IS |
| | LOCATED ABOVE THE BASE FLOOD ELEVATION AND ABOVE THE |
| | ADDITIONAL SIX INCHES THE CITY REQUIRES TO RECEIVE |
| | ADDITIONAL DISCOUNTS FOR STRUCTURES LOCATED IN "A" |
| | FLOOD ZONES. PLEASE REVIEW SECTION C OF THE CERTIFICATE |
| | SECTION C2 E). THIS LINE INDICATES THE ELEVATION OF |
| | MACHINERY OR EQUIPMENT SERVICING THE BUILDING, AND THE |
| | ELEVATION IS INDICATED AT 13.50 NGVD. THE A/C EQUIPMENT |
| | IS LOCATED 3'-0" BELOW THE 16.5' REQUIRED. |
| | |
| | IN THE FEMA PUBLICATION SUBSTANTIAL IMPROVEMENT |
| | SUBSTANTIAL DAMAGE THERE ARE SEVERAL ILLUSTRATIONS |
| | WHERE LATERAL ADDITIONS MAY OR MAY NOT IMPACT POST FIRM |
| | BUILDINGS AND THEIR EQUIPMENT. IN YOUR CASE THE |
| | ADDITION IS A NEW ATTACHED BUILDING WITH A 4 HOUR FIRE |
| | WALL CREATING AN ATTACHED BUT SEPARATE BUILDING AS FAR |
| | AS THE BUILDING CODE IS CONCERNED BECAUSE OF FBC-B |
| | TABLE 503 FOR ALLOWABLE AREA AND HEIGHT. WHEN WE LOOK |
| | AT THE FEMA REQUIREMENTS, THERE ARE THREE ISSUES THAT |
| | CLASSIFY THIS AS AN ADDITION THAT EFFECTS THE EXISTING |
| | NON-COMPLIANT BUILDING. (1) THE ADDITION IS CLASSIFIED |
| | AS SUBSTANTIAL IMPROVEMENT, (2) THE TWO BUILDINGS DO |
| | SHARE PORTIONS OF A COMMON 4 HOUR FIRE WALL, AND (3) |
| | COMMUNICATING OPENINGS BETWEEN THE TWO BUILDINGS. |
| | |
| | WE WILL NEED A NEW PROPOSED ELEVATION CERTIFICATE WITH |
| | EITHER: |
| | 1) THE EXISTING SLAB AND PROPOSED SLAB ABOVE THE BASE |
| | FLOOD ELEVATION OF 16.5' NGVD OR |
| | 2) SINCE THIS IS A NON-RESIDENTIAL BUILDING FLOOD |
| | PROOFING 1 FOOT ABOVE THE BASE FLOOD ELEVATION OR 17.5' |
| | NGVD. |
| | |
| | IN EITHER CASE ON THE FLOOD ZONE CERTIFICATE SECTION C2 |
| | E) NOT ONLY ASK AT WHAT ELEVATION THE EQUIPMENT IS SET |
| | BUT ALSO REQUIRES THE SURVEYOR TO DESCRIBE ON THE BACK |
| | OF THE FORM TYPE OF EQUIPMENT AND LOCATION OF EQUIPMENT |
| | UNDER THE HEADING OF "COMMENTS". |
| | |
| | FEMA NOW REQUIRES 3 FLOOD ZONE CERTIFICATES: |
| | 1) ONE BEFORE PERMIT ISSUANCE FOR THE PROPOSED WORK |
| | INDICATING THE FINISH FLOOR ELEVATION IN NGVD SINCE OUR |
| | FIRM MAPS ARE IN NGVD. |
| | 2) ONCE THE SLAB IS POURED THE ACTUAL FINISH FLOOR |
| | ELEVATION IN NGVD. |
| | 3) AT TIME OF (BEFORE) C/O WITH THE ATTENDANT MACHINERY |
| | AND OR EQUIPMENT SERVICING THE BUILDING. |
| | |
| | IF ANY OTHER QUESTIONS ARISE, PLEASE CONTACT US SO WE |
| | CAN HELP YOUR PROJECT ALONG. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |