Plan Review Details - Permit 12060310
Plan Review Stops For Permit 12060310
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2012-09-10 Cont ID  
Sent By jnguyen Date 2012-09-10 Time 16:08 Rev Time 0.00
Received By jnguyen Date 2012-09-10 Time 08:34 Sent To  
Notes
2012-09-10 15:46:28THIS PERMIT WAS FOR THE INTERIOR RENOVATION TO THE REAR
 STRUCTURE ON PCN# 74434315200020230. I BELIEVED THAT
 THERE WAS CONFUSION AS WHICH ADDRESS TO SPECIFICALLY
 REFERENCE FOR THIS REAR BUILDING (SUPPPOSE TO BE 430
 10TH ST, BUT THE SITE PLAN HAD 428 10TH ST). I
 CONTACTED THE PROPERTY OWNER, ABE HARUVI
 ([email protected]) TO CONFIRM THE ADDRESSING CHANGES
 THAT I IMPLEMENTED BACK IN 2010 AT CODE ENFORCEMENT'S
 REQUEST.
  
 MR. HARUVI CONFIRMED THAT THE ADDRESSES OF 428 & 430
 10TH ST FOR THESE TWO BUILDINS WERE SWAPPED ON
 10/22/2010, AS "PREVIOUSLY" 428 10TH ST USED TO
 REFERENCE THE BACK BUILDING, WHEREAS 430 10TH ST WAS
 ONCE THE FRONT BUILDING. CURRENTLY SINCE THESE CHANGES
 WERE IMPLEMENTED ON 10/22/2012, 428 10TH ST (PRIMARY
 ADDRESS) NOW REFERS TO THE FRONT BUILDING & 430 10TH ST
 (SECONDARY ADDRESS) PERTAINS TO THE REAR BUILDING.
 THEREFORE, I RE-REFERENCED THIS DIGITAL PERMIT RECORD
 IN COMMUNITYPLUS FROM 428 10TH ST TO THE CORRECT ONE OF
 430 10TH ST, AND I MADE THE REVISION TO THE ACTUAL
 HARDCOPY. I ALSO CALLED JOHN H. GRIFFIN II (AUTHOR OF
 THE SITE PLAN) TO ADVISE HIM OF THE CORRECT ADDRESS TO
 REFERENCE. THE ASSOCIATED DOCUMENTS WERE RETURNED TO
 THE B20 BOX.
  
  
 JOHN NGUYEN
 GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 PUBLIC UTILITIES DEPARTMENT
 OFFICE: (561) 822-1239
 FAX: (561) 822-1249
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-09-05 Cont ID  
Sent By jwitmer Date 2012-09-05 Time 14:23 Rev Time 0.00
Received By jwitmer Date 2012-09-05 Time 13:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-07-03 Cont ID  
Sent By jwitmer Date 2012-07-03 Time 15:25 Rev Time 0.00
Received By jwitmer Date 2012-06-28 Time 13:29 Sent To  
Notes
2012-07-03 15:48:02BUILDING PLAN REVIEW
 PERMIT: 12060310
 ADD: 428 10TH STREET
 CONT: RECORD CONSTRUCTION
 TEL: (561)662-2775
 2010 FLORIDA BUILDING CODE/ RESIDENTIAL W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) 2010 FBC-R 3012.1.2PROTECTION OF OPENINGS, THE
 CONTRACTOR SUBMITTED PRODUCT APPROVALS FOR EXTERIOR
 DOORS AND MULLIONS BUT NO WINDOW APPROVALS
 WERE SUBMITTED WTIHIN THIS PERMIT PACKAGE.
  
 2) 2010 WPB ADMINISTRATIVE CODE 107.3.4.1 DESIGN
 PROFESSIONALS SHALL REVIEW PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9N-3 , SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 3) 2010 FBC-R R807.1 ATTIC ACCESS. BUILDINGS WITH
 COMBUSTIBLE CEILING OR ROOF CONSTRUCTION SHALL HAVE AN
 ATTIC ACCESS OPENING TO ATTIC AREAS THAT EXCEED 30
 SQUARE FEET (2.8 M2) AND HAVE A VERTICAL HEIGHT OF 30
 INCHES (762 MM) OR MORE.
  
 THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22
 INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE
 LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE
 LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED
 HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME
 POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3
 FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS
 LOCATED IN ATTICS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-08-13 Cont ID  
Sent By rlecky Date 2012-08-13 Time 13:55 Rev Time 0.00
Received By rlecky Date 2012-08-13 Time 13:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-06-15 Cont ID  
Sent By rlecky Date 2012-06-15 Time 12:10 Rev Time 0.00
Received By rlecky Date 2012-06-15 Time 11:50 Sent To  
Notes
2012-06-15 12:13:1112060310
 428 10TH ST.
 APARTMENT RENOVATIONS
  
 MAXIMUM NUMBER OF DISCONNECTS FOR THE ELECTRICAL
 SERVICE IS LIMITED TO SIX SWITCHES GROUPED IN ONE
 LOCATION. SHOW LOCATION OF METER AND DISCONNECT ON THE
 STRUCTURE. NEC 230.70
 ADD RECEPTACLES SO THAT AT NO POINT ALONG THE FLOOR IN
 ANY WALL IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET
 AND AT WALL SPACES 2 FEET OR MORE IN WIDTH. NEC 210.52
 GFCI PROTECTED OUTLETS UNIT ARE REQUIRED FOR EACH
 DWELLING AT GRADE LEVEL FRONT AND BACK. NEC 210.52(E)
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT
 ALREADY EXIST WITHIN THE RESIDENCE. IF THE RESIDENCE
 HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE
 A CARBON MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET
 OF EACH ROOM USED FOR SLEEPING. 2007 FBC R313
  
 ROBERT LECKY
 ELECTRIC PLANS EXAMINER
 [email protected]
 561-805-6718
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-09-08 Cont ID  
Sent By wjolin Date 2012-09-08 Time 14:01 Rev Time 0.00
Received By wjolin Date 2012-09-08 Time 13:58 Sent To AD
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-06-15 Cont ID  
Sent By wjolin Date 2012-06-15 Time 12:05 Rev Time 0.00
Received By wjolin Date 2012-06-15 Time 10:59 Sent To  
Notes
2012-06-15 11:38:27428 10TH STREET
 PERMIT #12060310
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 INDICATE THE OCCUPANCY TYPE OF THIS BUILDING. DO EACH
 OF RENTAL UNITS HAVE SEPARATE COOKING FACILITIES? THE
 LAST OCCUPANCY ON RECORD (2002) AT THE FIRE DEPARTMENT
 IS FOR A LODGING/ROOMING HOUSE. INDICATE IF THE
 EXISTING FIRE ALARM SYSTEM FUNCTIONAL.
  
 PROVIDE A KEY PLAN. INDICATE WHERE UNIT #7 IS IN
 RELATION TO THE OTHER RENTAL UNITS.
  
 DESIGN SHALL CONFORM TO THE 2010 EDITION OF THE FLORIDA
 FIRE PREVENTION CODE WHICH CONTAINS THE 2009 EDITION OF
 BOTH NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS.
  
 ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO
 THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION
 DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. SMOKING
 SHALL BE PROHIBITED. ALL DEMOLITION OR CONSTRUCTION
 AREAS SHALL HAVE "NO SMOKING" SIGNS POSTED.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 INDICATE HOW THE SMOKE ALARMS ARE POWERED.
  
 STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R/F/RF
 DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA
 ADMINISTRATIVE CODE 69A-60.0081.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-09-25 Cont ID  
Sent By lmartine Date 2012-09-10 Time 10:46 Rev Time 0.00
Received By lmartine Date 2012-08-03 Time 07:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-07-03 Cont ID  
Sent By jwitmer Date 2012-07-03 Time 15:48 Rev Time 0.00
Received By jwitmer Date 2012-06-12 Time 15:39 Sent To  
Notes
2012-06-12 15:43:08B20

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2012-06-27 Cont ID  
Sent By hmoser Date 2012-06-27 Time 14:28 Rev Time 0.00
Received By hmoser Date 2012-06-27 Time 14:25 Sent To  
Notes
2012-06-27 14:28:12PERMIT NOT REQUIRED FOR WALL UNITS.
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-08-10 Cont ID  
Sent By lwagner Date 2012-08-10 Time 14:07 Rev Time 0.00
Received By lwagner Date 2012-08-10 Time 12:48 Sent To  
Notes
2012-08-10 14:07:37RE-STAMPED

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-06-18 Cont ID  
Sent By lwagner Date 2012-06-18 Time 13:57 Rev Time 0.00
Received By lwagner Date 2012-06-18 Time 13:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2012-09-04 Cont ID  
Sent By aaponte Date 2012-09-04 Time 16:08 Rev Time 0.00
Received By aaponte Date 2012-09-04 Time 16:08 Sent To  
Notes
2012-09-04 16:08:42PROVISO: EXISTING GRAVEL SHALL BE REPLACED BY GRASS,
 GROUND COVER OR ANY OTHER SUITABLE PLANT MATERIAL.

Review Stop Z ZONING
Rev No 1 Status P Date 2012-06-26 Cont ID  
Sent By aaponte Date 2012-06-26 Time 10:28 Rev Time 0.00
Received By aaponte Date 2012-06-26 Time 10:28 Sent To  
Notes
2012-06-26 10:29:26PROVISO: EXISTING GRAVEL SHALL BE REPLACED BY GRASS,
 GROUND COVER OR ANY OTHER SUITABLE PLANT MATERIAL.