Plan Review Details - Permit 12060138
Plan Review Stops For Permit 12060138
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-09-17 Cont ID  
Sent By shill Date 2012-09-17 Time 11:37 Rev Time 0.00
Received By shill Date 2012-09-17 Time 11:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-06-29 Cont ID  
Sent By shill Date 2012-06-29 Time 19:41 Rev Time 0.00
Received By shill Date 2012-06-29 Time 19:41 Sent To  
Notes
2012-06-29 19:42:01****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. VALUE TOO LOW, FBC 108.3. VALUE IS TO INCLUDE MARKET
 VALUE OF LABOR AND MATERIALS.
  
 2. PLEASE EXPLAIN THE DESIGN CRITERIA OF "HVHZ EXPOSURE
 B." ALL OF HVHZ IS EXPOSURE C, THIS PARCEL IS NOT
 LOCATED IN HVHZ BUT IS LOCATED IN EXPOSURE C. REVISE
 DESIGN CRITERIA TO MEET MINIMUM CODE COMPLIANCE FOR THE
 SITE, FBC 1609..4.3.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-09-17 Cont ID  
Sent By shill Date 2012-09-17 Time 11:37 Rev Time 0.00
Received By shill Date 2012-09-07 Time 11:03 Sent To  
Notes
2012-09-07 11:03:48ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-06-29 Cont ID  
Sent By shill Date 2012-06-29 Time 19:44 Rev Time 0.00
Received By shill Date 2012-06-06 Time 08:39 Sent To  
Notes
2012-06-07 08:39:32SENT TO ZONING SHELF FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2012-09-13 Cont ID  
Sent By eschneid Date 2012-09-13 Time 10:31 Rev Time 0.25
Received By eschneid Date 2012-09-13 Time 10:31 Sent To B
Notes
2012-09-13 10:31:24PASSED
  
 SIGNAGE ALLOWED - 233 SQ. FT.
 PROPOSED SIGN - 55 SQ. FT.
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2012-06-18 Cont ID  
Sent By eschneid Date 2012-06-18 Time 11:27 Rev Time 0.00
Received By eschneid Date 2012-06-08 Time 15:11 Sent To B
Notes
2012-06-18 11:43:04FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES TO THE COMMENTS.
  
 1) PROVIDE THE FACADE AREA DIMENSIONS FOR THE BUILDING.
 PLEASE REMEMBER THAT THIS SIGN IS NOT MOUNTED ON THE
 FRONT FACADE, SO IT MAY ONLY BE 50% OF THE SIZE LISTED
 IN THE BUILDING FACADE SIGN AREA TABLE.
  
 2) THE SIGN IS TO CONTAIN THE NAME AND/OR LOGO OF THE
 BUILDING OCCUPANT. THE BUSINESS TAX FOR THIS BUILDING
 LISTS THE TENANT AS "DAILY BREAD FOOD BANK". THERE IS
 NO "FEEDING SOUTH FLORIDA" LISTED AS OCCUPYING THE
 BUILDING.
  
 3) PLEASE PROVIDE INFORMATION ON HOW FAR THE SIGN
 PROJECTS FROM THE WALL.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2012-06-08 15:11:13GIVEN TO ES


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved