Plan Review Details - Permit 12060129
Plan Review Stops For Permit 12060129
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-07-11 Cont ID  
Sent By rmcdouga Date 2012-07-11 Time 15:18 Rev Time 0.00
Received By rmcdouga Date 2012-07-11 Time 14:20 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-06-27 Cont ID  
Sent By rmcdouga Date 2012-06-27 Time 11:03 Rev Time 0.00
Received By rmcdouga Date 2012-06-27 Time 10:25 Sent To  
Notes
2012-06-27 11:00:362010 FBC
  
 DENIED BY BUILDING
  
 1) THE PRODUCT APPROVALS REQUIRED BY DCA RULE 9N-3 ARE
 REQUIRED TO BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF THE PROJECT. CITY AMENDMENTS 107.3.4.1
  
 2) THE PRODUCT APPROVALS FOR THE CONSTRUCTION GLASS
 INDUSTRIES SERIES '450' OUT-SWING ALUMINUM DOOR NOA NO.
 06-0127.02 IS EXPIRED. PLEASE SUBMIT CURRENT PRODUCT
 APPROVALS. DCA RULE 9N-3
  
 3) THE PRODUCT APPROVALS FOR THE BIRDVIEW SKYLIGHTS NOA
 NO. 08-0611.09 HAS BEEN SUPERSEDED. PLEASE SUBMIT
 CURRENT PRODUCT APPROVALS. DCA RULE 9N-3
  
 4) SHOW THE LOCATIONS AND SIZE OF THE NEW SKYLIGHTS ON
 THE REAR ELEVATION AND SPECIFY THE REQUIRED WIND LOAD
 PRESSURES FOR THEM ON THE PLANS. FBC R301.2.1
  
 5) PROVIDE A DETAIL OF THE SKYLIGHT CONSTRUCTION.
 INCLUDE FRAMING, FINISH AND INSULATION INFORMATION ON
 THE DETAIL. CITY AMENDMENTS 107.2.1.3
  
 5) SPECIFY THE SIZE OF THE SLIDING GLASS DOOR AND THE
 REQUIRED WIND LOAD PRESSURES FOR THEM ON THE PLANS. FBC
 R301.2.1
  
 6) SPECIFY THE ACTUAL DOOR AND SIDELITE SIZES FOR THE
 FRONT AND REAR DOORS ON THE PLANS. CITY AMENDMENTS
 107.2.1.3
  
 7) FROM THE SCALE ON THE PLANS IT APPEARS THAT THE
 FRONT DOOR IS 4' WIDE AND 8' IN HEIGHT. THE PRODUCT
 APPROVAL HAS A MAXIMUM WIDTH OF 3' FOR DOORS 8' IN
 HEIGHT AND 3' 6" FOR DOORS UP TO 7' 6" IN HEIGHT.
 PLEASE PROVIDE PRODUCT APPROVALS FOR THESE LARGER
 DOORS. DCA RULE 9N-3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-06-11 Cont ID  
Sent By rlecky Date 2012-06-11 Time 15:09 Rev Time 0.00
Received By rlecky Date 2012-06-11 Time 14:52 Sent To  
Notes
2012-06-11 15:09:56SEE REDLINED NOTES ON ELECTRIC PLAN.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2012-07-12 Time   Rev Time 0.00
Received By rlecky Date 2012-07-03 Time 17:57 Sent To  
Notes
2012-07-03 17:57:42TO RM

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-06-28 Cont ID  
Sent By jroach Date 2012-06-28 Time 15:58 Rev Time 0.00
Received By jroach Date 2012-06-06 Time 14:15 Sent To  
Notes
2012-06-07 14:16:01SENT TO R2 SHELF FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-06-22 Cont ID  
Sent By rmcdouga Date 2012-06-22 Time 09:51 Rev Time 0.00
Received By rmcdouga Date 2012-06-22 Time 09:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2012-07-12 Time   Rev Time 0.00
Received By mdekle Date 2012-07-12 Time 08:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2012-06-28 Cont ID  
Sent By jroach Date 2012-06-28 Time 15:58 Rev Time 0.00
Received By jroach Date 2012-06-28 Time 15:58 Sent To  
Notes
***NONE***