Plan Review Details - Permit 12050836
Plan Review Stops For Permit 12050836
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-10-15 Cont ID  
Sent By rmcdouga Date 2012-10-15 Time 11:22 Rev Time 0.00
Received By rmcdouga Date 2012-10-12 Time 16:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-09-17 Cont ID  
Sent By rmcdouga Date 2012-09-17 Time 10:44 Rev Time 0.00
Received By rmcdouga Date 2012-09-14 Time 15:14 Sent To  
Notes
2012-09-17 11:41:292010 FBC
  
 DENIED BY BUILDING
  
 1) THE COOLING SYSTEM SEER HAS BEEN WHITED OUT AND
 CHANGED FROM 14 SEER TO 13 SEER ON ENERGY CALCULATION
 FORM. THIS IS NOT ACCEPTABLE. THE ENERGY CALCULATIONS
 WILL HAVE TO BE RUN WITH THE 13 SEER SYSTEM IN ORDER TO
 OBTAIN AN ACCURATE DETERMINATION. SUBMIT NEW ENERGY
 CALCULATIONS THAT HAVE BEEN SIGNED AND DATED BY THE
 PREPARER AND THE OWNER/AGENT. 2010 FBC ENERGY
 CONSERVATION
  
 2) THE PRODUCT APPROVALS AND A KEY PLAN HAVE BEEN
 SUBMITTED FOR THE STORM PANELS. HOWEVER, THE
 INSTALLATION SCHEDULE WAS NOT. SUBMIT TWO COPIES OF AN
 INSTALLATION SCHEDULE CORRESPONDING WITH THE KEY PLAN
 FOR THE STORM PANELS. FROM THE PRODUCT APPROVAL,
 SPECIFY THE TYPE OF INSTALLATION, THE ANCHOR TYPE &
 SPACING, PANEL SPANS, ETC. CITY AMENDMENTS 107.2.1.3
 SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE DEVICES
 OR ASSEMBLIES IS AVAILABLE ON THE CONSTRUCTION SERVICE
 WEBSITE.
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PERMITS_FORMS.PHP
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-06-18 Cont ID  
Sent By rmcdouga Date 2012-06-18 Time 14:00 Rev Time 0.00
Received By rmcdouga Date 2012-06-14 Time 13:21 Sent To  
Notes
2012-06-14 13:46:492010 FBC
  
 DENIED BY BUILDING
  
 1) THE GENERAL NOTES ON SHEET A1 AND THE STRUCTURAL
 NOTES ON A4 SPECIFY THE 2007 FBC. THE 2010 FBC WENT
 INTO EFFECT ON MARCH 15, 2012 AND IS THE ONE THAT
 APPLIES TO THIS PROJECT. PLEASE CORRECT.
  
 2) SPECIFY THE DESIGN CRITERIA ON THE PLANS. THE WIND
 SPEED FOR THIS PROJECT IS 170 MPH VULT AND THE EXPOSURE
 CATEGORY IS B. FBC R301.2.1.1 AND R301.2.1.4
  
 3) PLEASE UPDATE THE REFERENCED DESIGN STANDARDS ON
 SHEET A4 TO COMPLY WITH THE 2010 FBC. THE 2008 EDITIONS
 OF ACI 315, 301 AND 530 / TMS 402, 602 / ASCE 5 , 6 ARE
 LISTED IN THE REFERENCED STANDARDS IN CHAPTER 43 OF THE
 2010 FBC.
  
 4) SPECIFY THE COMPONENT AND CLADDING WIND LOAD
 PRESSURES FOR THE WINDOWS AND DOORS ON THE PLANS. FBC
 R301.2.1 THE WIND LOAD SCHEDULE ON A4 ONLY LISTS WALL
 PRESSURES FOR 50 SQFT. IF YOU WISH TO PROVIDE WORST
 CASE WIND LOAD PRESSURES USE THE 10 SQFT AREA
 PRESSURES.
  
 5) DOOR #8 FROM THE GARAGE INTO THE RESIDENCE IS
 SPECIFIED IN THE SCHEDULE AS HOLLOW CORE. FBC R301.5.1
 REQUIRES SPECIFIC TYPES OF DOORS AT THIS LOCATION.
 PLEASE REVISE.
  
 6) THE ROOF ZONE DIAGRAM ON SHEET A4 IS INCORRECT. THE
 OUTSIDE CORNERS OF THE HIP ROOF ARE DESIGNATED AS ZONE
 3. SEE FIGURE R301.2(7).
  
 7) THE ROOM DIMENSIONS ARE MISSING FROM THE FLOOR
 PLANS. PLEASE CORRECT. CITY AMENDMENTS 107.3.5 AND R304
  
 8) THE TRUSS CONNECTOR SCHEDULE ON A4 DOES NOT SPECIFY
 THE MODEL NUMBER, LOADS, OR PRODUCT APPROVAL NUMBER FOR
 TRUSS ANCHORS A & B. FBC R802.1.6.5 AND DCA RULE 9N-3
  
 9) THE ENERGY CALCULATION FORMS ARE NOT SIGNED BY THE
 PREPARER OR THE OWNER/AGENT. FBC ENERGY CONSERVATION
 405.4.2
  
 10) THE ENERGY CALCULATION FORM SPECIFIES A 14 SEER
 COOLING SYSTEM AND THE MANUAL J CALCULATIONS SPECIFY A
 13 SEER SYSTEM. PLEASE CORRECT. FBC ENERGY CONSERVATION
 405.3
  
 11) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PER
 CITY AMENDMENTS 107.3.4.1.
  
 12) SUBMIT TWO COPIES OF THE 2010 COVERSHEET, THE
 PRODUCT CERTIFICATION AND INSTALLATION INSTRUCTIONS FOR
 EXTERIOR DOOR FL#8228. DCA RULE 9N-3
  
 13) SUBMIT TWO COPIES OF THE EVALUATION REPORT AND
 INSTALLATION INSTRUCTIONS FOR THE OVER HEAD GARAGE DOOR
 FL # 5302. DCA RULE 9N-3
  
 14) SUBMIT TWO COPIES OF THE 2010 COVERSHEET FOR THE
 TAMKO SHINGLES FL# 1956. DCA RULE 9N-3
  
 15) SUBMIT TWO COPIES OF THE 2010 COVERSHEET, THE
 PRODUCT EVALUATION REPORT AND INSTALLATION INSTRUCTIONS
 FOR THE STORM PANELS FL #11968. ALSO SUBMIT TWO COPIES
 OF A KEY PLAN AND AN INSTALLATION SCHEDULE. DCA RULE
 9N-3 AND CITY AMENDMENTS 107.2.1.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-06-11 Cont ID  
Sent By rlecky Date 2012-06-11 Time 14:33 Rev Time 0.00
Received By rlecky Date 2012-06-11 Time 12:51 Sent To  
Notes
2012-06-11 14:33:37SEE REDLINED COMMENTS ON ELECTRIC PLANS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-10-15 Cont ID  
Sent By rmcdouga Date 2012-10-15 Time 11:23 Rev Time 0.00
Received By rmcdouga Date 2012-09-21 Time 16:35 Sent To  
Notes
2012-09-21 16:36:05GAVE TO ROBBIE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-09-17 Cont ID  
Sent By rmcdouga Date 2012-09-17 Time 10:44 Rev Time 0.00
Received By rmcdouga Date 2012-08-24 Time 10:06 Sent To  
Notes
2012-08-27 10:07:02SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-06-22 Cont ID  
Sent By jroach Date 2012-06-22 Time 14:05 Rev Time 0.00
Received By jroach Date 2012-05-30 Time 13:18 Sent To  
Notes
2012-05-31 13:18:29SENT TO R1 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-10-16 Cont ID  
Sent By rmcdouga Date 2012-10-16 Time 10:45 Rev Time 0.00
Received By rmcdouga Date 2012-10-16 Time 10:45 Sent To  
Notes
2012-10-16 10:46:19MU-2012-019012

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-06-13 Cont ID  
Sent By rmcdouga Date 2012-06-13 Time 10:39 Rev Time 0.00
Received By rmcdouga Date 2012-06-13 Time 10:39 Sent To  
Notes
2012-06-13 10:40:19PALM BEACH COUNTY IMPACT FEE REVIEW WILL BE REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-06-06 Cont ID  
Sent By hmoser Date 2012-06-06 Time 15:03 Rev Time 0.00
Received By hmoser Date 2012-06-06 Time 14:44 Sent To  
Notes
2012-06-07 17:16:58PROVISO
  
 13 SEER REQUIRED, SUBMIT ARI PAGE AT INSPECTION
 EXHAUST FAN IN MASTER BATH REQUIRED (SHOWN ON ELEC
 PLAN), OR PROVIDE MINIMUM 3X3 WINDOW OPENING
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-09-14 Cont ID  
Sent By rmcdouga Date 2012-09-14 Time 15:13 Rev Time 0.00
Received By rmcdouga Date 2012-09-14 Time 14:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-06-13 Cont ID  
Sent By rmcdouga Date 2012-06-13 Time 10:44 Rev Time 0.00
Received By rmcdouga Date 2012-06-13 Time 10:36 Sent To  
Notes
2012-06-13 11:12:202010 FBC
  
 DENIED BY PLUMBING
  
 1) THE MINIMUM BRANCH PIPE SIZE FOR A WATER CLOSET IS 3
 INCHES PER FBC TABLE P3005.4.1. A TWO INCH HORIZONTAL
 BRANCH PIPE IS SHOWN FOR THE BATH ROOM GROUP THAT IS
 LOCATED NEAR THE GARAGE. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2012-06-22 Cont ID  
Sent By jroach Date 2012-06-22 Time 14:01 Rev Time 0.00
Received By jroach Date 2012-06-22 Time 14:01 Sent To  
Notes
2012-06-22 14:05:05ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 06.22.2012
 PERMIT NO.: 12050836
 ADDRESS: 824 SELKIRK
 CONTRACTOR/CONTACT: LORENZO VALDES
 TELEPHONE NO.: 561.582.0670
 SCOPE OF REVIEW: NEW SINGLE FAMILY RESIDENCE.
 ___________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ___________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY,
 PERMITS SHALL BE OBTAINED AND IMPROVEMENTS INSTALLED
 FOR THE FOLLOWING:
 A. LANDSCAPING IN ACCORDANCE WITH ARTICLE XIV OF THE
 CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS);
 B. IRRIGATION; AND
 C. DRIVEWAY
 2. THE AIR CONDITIONING CONDENSING UNIT SHALL BE A
 MINIMUM OF 2.67 FEET FROM THE SIDE PROPERTY LINE.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved