Plan Review Details - Permit 12050620
Plan Review Stops For Permit 12050620
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-06-12 Cont ID  
Sent By jwitmer Date 2012-06-12 Time 13:53 Rev Time 0.00
Received By jwitmer Date 2012-06-12 Time 13:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-05-30 Cont ID  
Sent By jwitmer Date 2012-05-30 Time 08:06 Rev Time 0.00
Received By jwitmer Date 2012-05-30 Time 07:33 Sent To  
Notes
2012-05-30 09:52:35BUILDING PLAN REVIEW
 PERMIT: 12050620
 ADD: 529 S FLAGLER DR 31 H
 CONT: CAMBRIDGE CONSTRUCTION
 TEL: (561)248-5266
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 APPLIED DATE: 5/21/2012
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET A-1:
  
 1A) PROJECT DATA: INDICATES THE PLANS WERE DESIGNED TO
 THE 2007 EXISTING BUILDING CODE. MARCH 15/ 2012
 STATWIDE THE 2010 FBC WAS ADOPTED BY SECTION 553.73 FS.
  
 1B) PROJECT DATA INDICATES SUITE H TO BE 2091 SQ FT
 /200 = 10.45 OCCUPANTS, YOU ROUND UP TO 11 OCCUPANTS.
 BOAF INFORMAL INTERPRETATION 5479 12/18/2007.
  
 1C) WIND LOAD CALCULATIONS ARE DESIGNED TO THE WRONG
 WIND CRITERIA, THE 2010 FBC-B WIND DESIGN IS ASCE 7-10,
 2010 FBC-B 1609.1.1/ CHAPTER 35 REFRENECED STANDARDS.
  
 1D) DETAIL A/ A-1 INDICATES THE USE OF WOOD PARTITIONS,
 PLEASE SEE THE REQUIRED USE OF 2010 FBC-B 603.1.1.1
 FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN
 NONBEARING PARTITIONS WHERE THE REQUIRED
 FIRE-RESISTANCE RATING IS LESS THAN 2 HOURS OR LESS.
  
 2) ENGINEERING EXPRESS SITE SPECIFIC ENGINEERING FOR A
 CORNER MULLION, THERE APPEARS TO BE A DISCREPANCY
 BETWEEN THE FLOOR PLAN SHEET A-1 OF SET OF PLANS, WHICH
 IS ALSO INCORPORATED INTO THE ENGINEERING DOCUMENT
 INDEX SHEET A5 CLIENT SUPPLIED DOCUMENT AND THE MULLION
 CORNER DETAIL PAGE 4 OF 14 A 6'X6'X1/8 INCH ALUMINUM
 TUBE.
 THE TWO ARCHITECTURAL DETAILS INCORPARATE WHAT APPEARS
 TO BE A WALL SECTION BEFORE THE ATTACHMENT OF SLIDING
 GLASS DOORS. 2010 FBC-B 1715.5.5.2 LOAD TRANSFERS.
 MULLIONS SHALL BE DESIGNED TO TRANSFER THE DESIGN
 PRESSURE LOADS APPLIED BY THE WINDOW AND DOOR
 ASSEMBLIES TO THE ROUGH OPENING SUBSTRATE. THE CODE
 LIMITS THE TRANSFER OF LOADING TO WINDOW & DOOR SYSTEMS
 TO MULLIONS.
  
 IF THIS 6"X6"X1/8 INCH ALUMINUM TUBE IS TO BE CONSIDERD
 A STRUCTURAL COLUMN WITH WALL SECTION DEPICTED THEN
 DETAIL THE INFILE AND TYPE OF FRAMING, ANCHORING, TYPE
 OF EXTERIOR WALL FINISH FOR THIS AREA. 106.1.2
 ADDITIONAL INFORMATION REQUIRED, PART OF THE (MWFRS)
 MAIN WIND FORCE RESISTING SYSTEM.
  
 3) PRODUCT APPROVALS PLEASE HIGHLIGHT (CIRCLE) TYPE OF
 GLAZINGFOR ASSOCIATED PRESSURES, IF STEEL REINFORCEMENT
 IS REQUIRED, ANCHORS FOR REVIEW BY THE DESIGN
 PROFESSIONAL.
 2010 107.3.4.1*. THOSE PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING
 BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 4) ADDITIONAL INFORMATION REQUIRED, 107.2.1.3 SHEET A2
 DEMO PLAN INDICATES THE REMOVAL OF A PORTION OF KITCHEN
 CABINETS AND EXISTING CONCRETE SLAB MAY BE EXPOSED,
 PLANS ARE SILENT IF NEW FLOOR COVERINGS ARE GOING TO
 TAKE PLACE UNDER THIS PERMIT. PLEASE BE AWARE OF 2010
 FBC-B 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING
 ASSEMBLIES BETWEEN DWELLING UNITS OR BETWEEN A DWELLING
 UNIT AND A PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE
 SHALL HAVE AN IMPACT INSULATION CLASS (IIC) RATING OF
 NOT LESS THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN
 ACCORDANCE WITH ASTM E 492.
 AND:
 2010 603.1 ALLOWABLE MATERIALS. COMBUSTIBLE MATERIALS
 SHALL BE PERMITTED IN BUILDINGS OF TYPE I OR TYPE II
 CONSTRUCTION IN THE FOLLOWING APPLICATIONS AND IN
 ACCORDANCE WITH SECTIONS 603.1.1 THROUGH 603.1.3(2):
 1. INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
  
 2.INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND
 SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE
 ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
 200.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-05-22 Cont ID  
Sent By rlecky Date 2012-05-22 Time 09:10 Rev Time 0.00
Received By rlecky Date 2012-05-22 Time 09:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2012-05-30 Cont ID  
Sent By wjolin Date 2012-05-30 Time 12:07 Rev Time 0.00
Received By wjolin Date 2012-05-30 Time 11:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-06-12 Cont ID  
Sent By jwitmer Date 2012-06-12 Time 13:52 Rev Time 0.00
Received By jwitmer Date 2012-06-12 Time 08:15 Sent To  
Notes
2012-06-12 08:15:48INCOMING SENT TO JW DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-30 Cont ID  
Sent By lwagner Date 2012-05-30 Time 15:30 Rev Time 0.00
Received By lwagner Date 2012-05-21 Time 17:14 Sent To  
Notes
2012-05-21 17:14:26EXPEDITED
 B--1

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2012-05-23 Cont ID  
Sent By hmoser Date 2012-05-23 Time 13:03 Rev Time 0.00
Received By hmoser Date 2012-05-23 Time 12:56 Sent To  
Notes
2012-05-23 13:02:55AIRCONDITIONING CONTRACTOR IS GOING TO SUBMIT
 APPLICATION AND PLANS FOR REVIEW.
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-05-30 Cont ID  
Sent By lwagner Date 2012-05-30 Time 15:30 Rev Time 0.00
Received By lwagner Date 2012-05-30 Time 15:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2012-05-23 Cont ID  
Sent By eschneid Date 2012-05-23 Time 16:36 Rev Time 0.25
Received By eschneid Date 2012-05-23 Time 16:36 Sent To  
Notes
2012-05-23 16:38:27INTERIOR ONLY. LESS THAN 50% OF UNIT COST.