| Plan Review Stops For Permit 12050473 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-24 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-24 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2012-05-24 12:36:16 | ***PROVISO*** | | | | | | THIS PARCEL IS LOCATED IN EXPOSURE D. REVISE RAS 117 | | | CALCULATIONS AND PROVIDE AT INSPECTION. | | | | | | STRAP/NAILING FOR MITIGATION TO BE FIELD VERIFIED AT | | | INSPECTION. | | | | | | ISSUED AT CONTRACTOR'S RISK | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-16 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-16 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2012-05-16 11:25:48 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PLEASE INCLUDE THE MEAN ROOF HEIGHT AND ROOF PITCH, | | | FBC R 301.2. IF DESIGN PRESSURES ARE NOT PROVIDED PER | | | ASCE7-10, TABULAR VALUES WILL BE USED. NOTE THAT THIS | | | PARCEL REQUIRES WIND DESIGN CRITERIA OF 170MPH EXPOSURE | | | D. ***PLEASE ADVISE ENGINEER THAT THIS IS EXPOSURE D*** | | | | | | 2. PROPOSAL STATES THAT POLY FOAM WILL BE USED FOR THE | | | TILE ROOF; PLEASE PROVIDE PRODUCT APPROVAL, FAC9N-3. | | | | | | 3. ENGINEERING REQUIRED FOR ENHANCED FASTNING FOR THE | | | FLAT DECK, SEE GENERAL LIMITATION #7 ON THE LAST PAGE | | | OF THE MIAMIDADE NOA. | | | | | | 4. PROVIDE SQUARE FOOT AREA OF EACH ROOF TYPE, FBC | | | 108.3. | | | |
|
|
|