Plan Review Details - Permit 12050438
Plan Review Stops For Permit 12050438
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-06-22 Cont ID  
Sent By jgomez Date 2012-06-22 Time 13:18 Rev Time 0.00
Received By jgomez Date 2012-06-22 Time 13:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-06-11 Cont ID  
Sent By jgomez Date 2012-06-11 Time 10:14 Rev Time 0.00
Received By jgomez Date 2012-06-11 Time 10:14 Sent To  
Notes
2012-06-11 10:14:37RESIDENTIAL (R3) REVISION, SECOND BUILDING REVIEW
 COMMENTS.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- DCA RULE 9N-3. PLEASE PROVIDE PRODUCT APPROVAL COVER
 PAGE FOR:
 A) JELD-WEN CUSTOM CLAD CASEMENT WINDOW. FL15438
 SUBMITTED IS PENDING FBC APPROVAL. NEED FBC APPROVED
 STATUTES OR TO APPLY FOR LOCAL PRODUCT APPROVAL.
  
 B) JELD-WEN CUSTOM CLAD FIXED CASEMENT WINDOW. SEE
 COMMENT 1(A) ABOVE.
  
 C) FRENCH DOOR NOA 08-0429.06 SUBMITTED IS FOR DOORS
 WITH NO IMPACT GLAZING. NEED TO PROVIDE OPENING
 PROTECTION AS REQUIRED BY SEC. 606.4 OF 2007
 FBC-EXISTING BUILDING.
  
 3- FOR YOUR INFORMATION ONLY: REPLACEMENT OF WINDOWS
 AND DOORS REQUIRE BUCK INSPECTION. MAKE SURE
 INSPECTIONS ARE PROPERLY SCHEDULED TO AVOID ANY DELAYS
 OR CONFLICTS WITH THE INSTALLATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-05-16 Cont ID  
Sent By jgomez Date 2012-05-16 Time 16:42 Rev Time 0.00
Received By jgomez Date 2012-05-16 Time 16:05 Sent To  
Notes
2012-05-16 16:42:49RESIDENTIAL (R3) REVISION, BUILDING REVIEW COMMENTS.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- REVISION FEES NEED TO BE PAID.
  
 2- DCA RULE 9N-3. PLEASE PROVIDE PRODUCT APPROVAL COVER
 PAGE FOR:
 A) JELD-WEN CUSTOM CLAD CASEMENT WINDOW. ONLY THE
 DRAWINGS WERE SUBMITTED, BUT THERE IS NOT COVER PAGE
 SHOWING IF IT WAS APPROVED OR NOT.
  
 B) JELD-WEN CUSTOM COLLECTION ALUMINUM CLAD INSASH
 CASEMENT WINDOW. SEE COMMENT 1(A) ABOVE.
  
 C) MULLIONS NOA 10-1115.03: CLEARLY SPECIFY MULLION
 SIZE AND NUMBER OF MULLIONS. SINGLE MULLIONS CAN'T BE
 USED FOR DOOR INSTALLATION BECAUSE THE MAXIMUM MULLION
 SPAN FOR SINGLE MULLION IS 72". SEE DESIGN SCHEDULE ON
 SHEET 6 OF NOA SUBMITTED.
  
 3- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS PRIOR
 TO SUBMITTAL TO THIS OFFICE. SEC. 106.3.3 OF CITY
 AMENDMENTS TO FBC.
  
 4- THERE ARE 2 DIFFERENT FLOOR PLANS SUBMITTED. ONE IS
 COMING FROM REG ARCHITECTS AND THE OTHER ONE IS AN
 SKETCH. THEY DON'T MATCH. CLARIFY WHICH IS THE CORRECT
 ONE.
  
 5- FOR YOUR INFORMATION ONLY: REPLACEMENT OF WINDOWS
 AND DOORS REQUIRE BUCK INSPECTION. MAKE SURE
 INSPECTIONS ARE PROPERLY SCHEDULED TO AVOID ANY DELAYS
 OR CONFLICTS WITH THE INSTALLATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2012-06-19 Cont ID  
Sent By fmittner Date 2012-06-19 Time 09:46 Rev Time 0.00
Received By fmittner Date 2012-06-19 Time 09:46 Sent To  
Notes
2012-06-19 08:56:25GIVEN TO FM

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2012-05-15 Cont ID  
Sent By fmittner Date 2012-05-15 Time 15:13 Rev Time 0.00
Received By fmittner Date 2012-05-15 Time 13:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-06-22 Cont ID  
Sent By jgomez Date 2012-06-22 Time 13:56 Rev Time 0.00
Received By jgomez Date 2012-06-15 Time 11:14 Sent To  
Notes
2012-06-20 07:47:586/20 TO JG DESK
  
2012-06-15 11:14:21TO ZONING (HISTORICAL)

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-06-11 Cont ID  
Sent By jgomez Date 2012-06-11 Time 12:11 Rev Time 0.00
Received By jgomez Date 2012-06-05 Time 08:28 Sent To  
Notes
2012-06-05 08:29:37TO JG

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-16 Cont ID  
Sent By jgomez Date 2012-05-16 Time 17:11 Rev Time 0.00
Received By jgomez Date 2012-05-16 Time 15:27 Sent To  
Notes
2012-05-16 15:27:39TO JG DESK
  

Review Stop Z ZONING
Rev No 1 Status P Date 2012-05-15 Cont ID  
Sent By fmittner Date 2012-05-15 Time 15:15 Rev Time 0.00
Received By fmittner Date 2012-05-15 Time 15:15 Sent To  
Notes
***NONE***