Plan Review Stops For Permit 12050325
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-05-24 Cont ID  
Sent By jwitmer Date 2012-05-15 Time 15:11 Rev Time 0.00
Received By jwitmer Date 2012-05-15 Time 13:11 Sent To  
Notes
2012-05-15 16:33:195/24/2012
 CONTRACTOR BROUGHT IN CORRECTED PRODUCT APPROVALS, SHOP
 DRAWINGS AND ASSOCIATED PRESSURES.
  
  
  
 BUILDING PLAN REVIEW
 PERMIT: 12050325
 ADD: 606 FOREST HILL BLVD
 CONT: ADVANCED DEVELOPMENT & CONSTRUCTION OF FL, LLC
 TEL: (561)239-4122
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET S-1 INDICATES THE BAR JOIST ARE CANTILEVERED
 FOR THE FRONT PORTION OF THE BUILDING, BUT THE PLANS
 ALSO INDICATE ALL OF THE FRONT WALLS ARE NON-LOAD
 BEARING WALLS, WHERE IS THE FRONT SUPPORT SYSTEM FOR
 THE CANTILEVERED BAR JOIST.? 106.1.2 ADDITIONAL
 INFORMATION REQUIRED, WHAT PART OF THE SYSTEM IS THE
 MAIN WIND FORCE RESISTING SYSTEM (MFRRS).
  
 2)DETAIL # 3 SHEET S1 INDICATES BY THE WALL LEGEND THIS
 TO BE A NEW 2X8 NON-BEARING EXTERIOR WALL, PLANS DO NOT
 INDICATE CLEARLY HOW THE WALL WILL BE SECURED TO THE
 EXISTING BAR JOIST TO ANCHOR THE WALL FROMLATERAL
 MOVEMENT IN A HIGH WIND EVENT. PLEASE PROVIDE THE
 SPACING OF THE BAR JOIST.
  
 3) THE SAME SITUATION WILL OCCUR WITH THE ACCORDIAN
 STORM SHUTTERS, THERE IS NO DETAIL HOW THE STORM
 SHUTTERS WILL BE ANCHORED INTO THE MAIN WIND FORCE
 RESISTING SYSTEM. PLEASE NOTE THE ACCORDIAN SHUTTER
 PRODUCT APPROVAL HAS VERY LIMITED TESTING DETAILS FOR
 THE UPPER TRACK AND ANCHORING DETAILS. PLEASE
 HIGHLIGHT, CIRCLE ALL DETAILS, BLADE TYPE, VERTICLA
 LENGHT AND ANCHORING REQUIREMENTS FOR THIS INSTALATION.
 CIRCLE THE CLEARENCE REQUIRED FROM THE GLASS TO THE
 SHUTTER.
  
 4) PLEASE HIGHLIGHT THE VARIOUS CONDITIONS FOR
 ANCHORING THE ACCORDIAN SHUTTER TO THE NON-LOAD BEARING
 WALL, IT APPEARS THE EXTERIOR WALLS ARE TO BE PART OF
 THE MAIN WIND FORCE RESISTING SYSTEM SINCE THE STORM
 SHUTTERS ARE GOING TO BE ATTACHED TO THEM.
  
 5) SHEET S-1 DETAIL # 2 IS NOT CLEAR HOW TO TERMINATE
 THE STEEL 6"X3" STEEL TUBE, IS THERE TO BE STEEL TUBING
 ABOVE THE BOTTOM LEG OF THE BAR JOIST TO CONTINUE
 THROUGH TO THE NEXT BAR JOIST SO THE 6"X3" TUBE IS NOT
 CANTILEVERED? 106.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 6) SHEET S-1 DETAIL # 2 IS ALSO MISSING STRAPPING AT
 THE TOP PLATE LOCATION. THERE IS NO DETAIL ABOUT THE
 BOTTOM ANCHORING OF THIS AREA, DOES THE FRAMING
 CONTINUE TO THE FLOOR OR DOES THE BLOCK
 KNEE WALL CONTINUE THROUGH THIS AREA? 106.1.2.
  
 7) PLANS INDICATE STONE OR STUCCO FINISHAPPLY PER
 PRODUCT SPECIFICATIONS PLEASE BE AWARE OF 2010 FBC-B
 1404.2 WATER-RESISTIVE BARRIER.
 EXTERIOR WALLS OF FRAME CONSTRUCTION RECEIVING A VENEER
 SHALL BE PROVIDED WITH A WATER-RESISTIVE BARRIER. THE
 WATER-RESISTIVE BARRIER SHALL BE A MINIMUM OF ONE LAYER
 OF NO. 15 ASPHALT FELT, COMPLYING WITH ASTM D 226 FOR
 TYPE 1 FELT OR OTHER APPROVED MATERIALS, SHALL BE
 ATTACHED TO THE SHEATHING, WITH FLASHING AS DESCRIBED
 IN SECTION 1405.3, IN SUCH A MANNER AS TO PROVIDE A
 CONTINUOUS WATER-RESISTIVE BARRIER BEHIND THE EXTERIOR
 WALL VENEER.
  
 1404.2.1 WHERE CEMENT PLASTER (STUCCO) IS TO BE APPLIED
 TO LATH OVER FRAME CONSTRUCTION, MEASURES SHALL BE
 TAKEN TO PREVENT BONDING BETWEEN THE CEMENT PLASTER AND
 THE WATER RESISTIVE BARRIER. A BOND BREAK SHALL BE
 PROVIDED BETWEEN THE WATER RESISTIVE BARRIER AND THE
 CEMENT PLASTER (STUCCO) CONSISTING OF ONE OF THE
 FOLLOWING:
  
 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER OR
  
 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER
 OVER AN APPROVED PLASTIC HOUSE WRAP, OR
  
 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN
 ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS.
  
 PLEASE PROVIDE CLEAR DETAIL AS TO THE FINISH TO BE
 APPLIED IN THIS PORTION OF THE STRUCTURE.
  
 8) SHEET S-1 ROUGH CARPENTRY NOTES INDICATE THE USE OF
 SECTION 2319, THIS CODE SECTION DEALS WITH HIGH
 VELOCITY HURRICANE ZONES, DADE AND BROWARD COUNTIES SEE
 DEFINITIONS FOR HIGH VELOCITY HURRICANE ZONES.
  
 9) PRODUCT APPROVAL NOA 10-1213.07 SMI SERIES "SM-45"
 ALUMINUM STOREFRONT N. I. PLEASE CIRCLE TYPE OF
 MULLIONS TO BE USED FROM SPAN CHARTS, CIRCLE TYPE OF
 REINFORED MULLION IF REQUIRED, CIRCLE TYPE OF ANCHORS
 TO BE INSTALLED, TOP (STEEL TUBE) AND BOTTOM (CONCRETE
 SILL) , CIRCLE SPAN TABLES FOR THE HORIZONTAL
 MULLIONSWITH OR WITHOUT REINFORCING AND TYPE OF
 ANCHORS,
 PLEASE BE AWARE ON SHEET 6 OF 8 NOTE STATING WOOD BUCKS
 AND METAL STRUCTURES NOT BY SMI ALUMINUM SYSTEMS. MUST
 SUPPORT LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER
 THEM TO THE BUILDING STRUCTURE.
  
 10) PRODUCT APPROVAL NOA 06-0405.03 SMITH MOUNTAIN
 SERIES "MCKINLEY" EXPIRED OCT. 26, 2011.
  
 11) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-24 Cont ID  
Sent By jwitmer Date 2012-05-24 Time 15:29 Rev Time 0.00
Received By jwitmer Date 2012-05-10 Time 10:57 Sent To  
Notes
2012-05-11 10:50:09EXPEDITED
 B--21

Review Stop Z ZONING
Rev No 1 Status N Date 2012-05-24 Cont ID  
Sent By lfranco Date 2012-05-24 Time 15:28 Rev Time 0.00
Received By jwitmer Date 2012-05-24 Time 15:28 Sent To  
Notes
2012-05-24 15:29:19I SPOKE WITH ERIC EXACT CHANGE OUT OF STOREFRONT
 GLAZING SYSTEM, ZONING REVIEW & STOP NOT NEEDED.