| Plan Review Stops For Permit 12050262 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-05-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-30 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-30 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2012-05-30 09:41:59 | REVISION DATED 5/19/12 | | | SHEETS A-1A, A-1C, A-1B, A2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-05-15 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-05-15 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2012-05-15 09:56:32 | BUILDING PLAN REVIEW | | | PERMIT:11090826 | | | REVISION: 12050262 | | | ADD: 1270 PALM BEACH LAKES | | | CONT: EVANS PETROLEUM SEERVICES | | | TEL: (305)796-9695 | | | | | | 2007 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET # A-1B PLANS DENOTE THE MINIMUM BUILDING TYPE | | | AS A BUILDING TYPE "VB" UNPROTECTED. | | | DISCREPANCY: | | | UNDER THE HEADING OF FIRE PROTECTION FBC TABLE 601 THE | | | MINIMUM BUILDING TYPE "VA" PROTECTED WITH BEARING | | | WALLS, STEEL & CONCRETE COLUMNS AND ROOF TO BE 1-HOUR | | | RATED? | | | 106.1.2 ADDITIONAL INFORMATION IS REQUIRED, PLEASE | | | PROVIDE CLARIFICATION AS TO IF THE BUILDING WILL BE | | | UNPROTECTED (VB) OR 1-HOUR FIRER RATED PROTECTED (VA). | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-05-30 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-30 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-30 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-15 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-15 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2012-05-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-05-29 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-05-29 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2012-05-10 |
|
|
Cont ID |
|
| Sent By |
ddaniels |
Date |
2012-05-10 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2012-05-10 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2012-05-10 12:52:25 | FIRE DEPARTMENT REVIEW ***DENIED*** | | | | | | 1. THE SCOPE OF WORK SHALL BE INDICATED ON PLANS. | | | 2. ALL DEMOLITION WORK SHALL CONFORM TO THE | | | REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS | | | SHALL BE REMOVED FROM THE SITE DAILY. | | | 3. PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY | | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | | TRAVEL ETC. | | | 4. NO LIFE SAFETY SHEETS | | | | | | | | | DERRICK L. DANIELS, BATTALION CHIEF | | | WEST PALM BEACH FIRE RESCUE | | | OFFICE OF THE FIRE MARSHAL | | | (561) 805-6722 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-05-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-30 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-29 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-05-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-22 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-09 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2012-05-09 17:14:16 | EXPEDITED | | | B--12 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-05-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-30 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-30 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2012-05-30 09:01:31 | PROVISO | | | SUBMIT REVISION WITH DUCT SIZE. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2012-05-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-22 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-22 |
Time |
15:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-05-30 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-05-30 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-05-30 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-05-14 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-05-14 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-05-14 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|