| Plan Review Stops For Permit 12050218 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-07-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-07-09 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-07-09 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-07-06 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-07-06 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2012-07-06 11:55:50 | BUILDING PLAN REVIEW | | | PERMIT: 12050218 | | | ADD: 2465 MERCER AVE # 105 | | | CONT: CROSSROADS CONSTRUCTION | | | TEL: (561)346-6160 | | | | | | 2007 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET A-1: | | | | | | 1) THE PROPERTY APPRAISERS SITE INDICATES THIS TO BE A | | | COMMERCIAL CONDOMINIUM SITE WITH SEPERATE UNITS, | | | PROPERTY LINES AND OWNERSHIP. PLANS WILL NEED TO | | | IDENTIFY UNITS AND ASSOCIATED PROPERTY LINES TO COMPLY | | | WITH 2010 FBC-B 709.1(6) TENANT SEPERATION WALLS. THE | | | DESIGNER WILL NEED TO IDENTIFY THE TENANT SEPERATION | | | WALL AS A 1 HOUR RATED WALL BETWEEN THE TWO UNITS PER | | | 2010 FBC-B 709.1.(6) WALLS SEPERATING TENANT SPACES. | | | THE DOOR ON MAG HOLD OPEN DEVICES SEPERATING THE TWO | | | TENANCIES WILL ALSO NEED TO BE A FIRE RATED DOOR SEE | | | TABLE 715.4 FIRE DOORS AND FIRE SHUTTERS. | | | | | | 7/09/20112 CONDO DOCS SUBMITTED PART OF PERMIT PACKAGE. | | | OK TO PASS. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-05-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-05-22 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-05-22 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2012-05-22 12:17:28 | BUILDING PLAN REVIEW | | | PERMIT: 12050218 | | | ADD: 2465 MERCER AVE # 105 | | | CONT: CROSSROADS CONSTRUCTION | | | TEL: (561)346-6160 | | | | | | 2007 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET A-1: | | | | | | 1A) THE PROPERTY APPRAISERS SITE INDICATES THIS TO BE A | | | COMMERCIAL CONDOMINIUM SITE WITH SEPERATE UNITS, | | | PROPERTY LINES AND OWNERSHIP. PLANS WILL NEED TO | | | IDENTIFY UNITS AND ASSOCIATED PROPERTY LINES TO COMPLY | | | WITH 2010 FBC-B 709.1(6) TENANT SEPERATION WALLS. | | | EXCEPTION # 6 FOR TENANT SEPERATION WALLS WILL NOT BE | | | APPLICABLE EVEN IF THE ASSUMED 3 SPACES WERE UNDER | | | 3,000 SQ FT THERE ARE 3 SEPERATE PCN NUMBERS, THESE ARE | | | NOT RENTAL UNITS UNDER ONE OWNERSHIP. | | | | | | NOTE 5/22/12 WAITING ON E-MAIL FOR LEASE AGREEMENT. JW | | | NOTE 5/23/12 RECEIVED LEASE AGREEMENT SPOKE WITH BO | | | DOUG WISE ABOUT LEGALLITY. | | | NOTE 5/24/12 SPOKE WITH OWNERS, OWNERS ARE TO COMBINE | | | UNITS UNDER ONE OWNERSHIP, WILL NEED TO COMPLETE A | | | UNITY OF TITLE UNDER OWN PCN. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-05-09 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-09 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-09 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2012-07-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-07-14 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-07-14 |
Time |
18:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2012-06-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-06-22 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-06-22 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2012-06-22 11:36:03 | 2465 MERCER AVENUE - SUITE #105 | | | PERMIT #12050218 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT: ALL DEMOLITION OR CONSTRUCTION AREAS | | | SHALL HAVE "NO SMOKING" SIGNS POSTED. | | | | | | REPEAT COMMENT: ALL EXTERIOR DOORS NOT FUNCTIONING AS | | | EXITS SHALL BE PERMANENTLY MARKED AND CLEARLY INDICATED | | | AS, "NOT AN EXIT." | | | | | | REPEAT COMMENT: SHEET A-2: PROVIDE FIRE ALARM | | | NOTIFICATION APPLIANCE IN CONFERENCE ROOM #2 AND IN | | | HALLWAY NEAR BREAK ROOM/COPY ROOM. | | | NEW COMMENT: ALL THE FIRE ALARM NOTIFICATION APPLIANCES | | | ORIGINALLY SHOWN ON SHEET A-2 ARE NO LONGER SHOWN. | | | | | | IN ORDER TO ISSUE A GENERAL BUILDING PERMIT, THE FIRE | | | ALARM AND FIRE SPRINKLER SCOPE OF WORK WOULD NEED TO BE | | | SHOWN OR DESCRIBED ON THE DESIGN DOCUMENTS. AFTER THE | | | GENERAL BUILDING PERMIT HAS BEEN ISSUED, THE | | | SUB-CONTRACTORS WILL NEED TO SUBMIT SHOP DRAWINGS (FIRE | | | ALARM AND FIRE SPRINKLER) FOR SPECIFIC SUB-PERMITS. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2012-05-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-05-29 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-05-29 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2012-05-29 10:26:33 | 2465 MERCER AVENUE - SUITE #105 | | | PERMIT #12050218 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH | | | FLORIDA AMENDMENTS SHOULD BE REFERENCED IN THE CODE | | | LIST. | | | | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. ALL | | | DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF | | | THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | PLANS DO NOT INDICATE THE SCOPE OF WORK FOR THE FIRE | | | SPRINKLER SYSTEM. ANY RESIDENTIAL TYPE SPRINKLERS WOULD | | | NEED TO BE REPLACED WITH COMMERCIAL STYLE SPRINKLERS. | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | MODIFICATION OF THE FIRE SPRINKLER SYSTEM AND FIRE | | | ALARM SYSTEM. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | ALL EXTERIOR DOORS NOT FUNCTIONING AS EXITS SHALL BE | | | PERMANENTLY MARKED AND CLEARLY INDICATED AS, "NOT AN | | | EXIT." | | | | | | SHEET A-2: PROVIDE FIRE ALARM NOTIFICATION APPLIANCE IN | | | CONFERENCE ROOM #2 AND IN HALLWAY NEAR BREAK ROOM/COPY | | | ROOM. | | | | | | SHEET A-3: PROVIDE EMERGENCY LIGHTING FOR EXIT PATH IN | | | MTC ROOM. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2012-07-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-07-14 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-07-13 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-07-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-07-11 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-07-02 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-07-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-06-22 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-06-15 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-06-07 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-08 |
Time |
18:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-07-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-07-11 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-07-11 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-05-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-18 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-18 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2012-05-18 14:17:01 | PLANS DENIED | | | PROVIDE FRESH AIR CALCULATIONS ON THE PLANS PER TABLE | | | 403.3 FBC (M) 2010 | | | REFER TO SECTION 503.2.1 CALCULATIONS OF HEATING AND | | | COOLING LOADS. | | | 2010 FLORIDA ENERGY CODE. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-06-20 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-06-20 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-06-20 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2012-06-20 09:34:39 | SINK TO BE INSTALLED DOWNSTREAM FROM WET VENT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2012-05-11 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-05-11 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-05-11 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2012-05-11 14:49:21 | FBC PLUMBING 2010 | | | FBC ACCESSIBILITY 2010 | | | REVIEW #1 | | | DENIED: | | | | | | 1. SHEET A-1 SHOWS RESTROOMS 5'-7" WIDE | | | FBC ACCESSIBILITY 2010 - 604.3.1 AND 604.3.2 REQUIRE A | | | 5' CLEAR SPACE FOR THE WATER CLOSET WITH NO OTHER | | | FIXTURES WITHIN THAT SPACE. | | | | | | 2. SHEET A-5 SHOWS A SINK ATTACHED TO A WET VENT | | | SYSTEM. THE SINK IS REQUIRED TO CONNECT DOWNSTREAM OF | | | THE WET VENTED RESTROOM. | | | FBC PLUMBING 909.1 HORIZONTAL WET VENT PERMITTED. ANY | | | COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | | LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE | | | VENTED BY A HORIZONTAL WET VENT.....ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2012-07-02 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-07-02 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-07-02 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-05-15 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-05-15 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|