Plan Review Details - Permit 12050036
| Plan Review Stops For Permit 12050036 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2012-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-13 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-08-13 |
Time |
18:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2012-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-06-07 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-06-07 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2012-06-07 17:09:56 | PLEASE REVISE THE INSTALLATION SHEDULE. | | | | | | SHUTTER TO GLASS SEPARATION - 4 1/2" CIRCLED ON PRODUCT | | | APPROVAL SHEET 5 (SEE ATTACHED), BUT 3 1/2" PROPOSED. | | | | | | SEE SHEET 6, ANCHOR SPACING CIRCLED BUT NOT CONSISTENT | | | WITH SPANS/SPACING ON THE INSTALLATION SHEDULE. A | | | COUPLE EXAMPLES: | | | | | | OPENING 1, TOP (CONNECTION TYPE 1) 60.3 PSF, 10`.2" | | | SPAN, NEED TO USE 11' ROW AND 70PSF COLUMN, 4" | | | REQUIRED. | | | BOTTOM, 5.5" REQUIRED FOR CONNECTION TYPE 6 | | | OPENINGS 2&3, 72.5PSF, 7.5' SPAN, 9" PROPOSED, NEED TO | | | USE 80PSF AND 8' ROW, CANNOT USE. | | | | | | FIRST SUBMITTAL USED LOWER PRESSURES. SECOND SUBMITTAL | | | HAS HIGHER PRESSURES PROPOSED. IT APPEARS THAT YOU ARE | | | USING V(ULT) PRESSURES WITHOUT CONVERTING TO V(ASD) FOR | | | USE WITH PRODUCT APPROVALS. IF YOU WOULD LIKE, YOU CAN | | | USE FBC RESIDENTIAL TABLE 301.2(2) TO CALCULATE EACH | | | OPENING OR YOU CAN USE +37.9/-50.7 "WORST CASE" (ZONE | | | 5, 10SF, 15MRH, EXPOSURE C). | | | | | | SAMANTHA HILL | | | 561-805-6724 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-05-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-29 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-29 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2012-05-29 17:31:14 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | 1. OK | | | | | | 2. 9" SPACING DOES NOT MEET MINIMUMS IN PRODUCT | | | APPROVAL FOR OPENINGS 8' AND GREATER, SEE SHEET 6, | | | CONNECTION TYPE 1. | | | | | | ANCHOR SPACING FOR OPENINGS 5 THROUGH 8 WERE LEFT | | | BLANK, PLEASE REVISE TO SHOW COMPLIANCE WITH FBC | | | RESIDENTIAL 301.1, WIND. | | | | | | 3. OK | | | | | | 4. PLEASE INCLUDE INFORMATION REGARDING TYPE OF | | | INSTALLATION; KNUCKLE OR LOCK/CENTERMATES IN ORDER TO | | | DETERMINE SHUTTER GLASS SEPARATION REQUIRED, SEE SHEET | | | 5 OF PRODUCT APPROVAL. | | | | | | WIND ZONE 3 WAS MARKED ON PRODUCT APPROVAL, WEST PALM | | | BEACH IS IN WIND ZONE 4 PER FBC RESIDENTIAL | | | 301.2.1.2.1. FIRST SUBMITTAL HAD A 4.5" SHUTTER GLASS | | | SEPARATION BUT WAS REDUCED TO 3" ON THE SECOND | | | SUBMITTAL. 3" DOES NOT COMPLY WITH THE TWO DIFFERENT | | | OPTIONS ON SHEET 5. | | | PLEASE PROVIDE REQUESTED INFORMATION (KNUCKLE OR | | | CENTERMATE) AND REVISE INSTALLATION SCHEDULE. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-10 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-10 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2012-05-10 13:39:55 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. SEE WIND MAP, WEST PALM BEACH LIES BETWEEN THE LINE | | | FOR 160MPH AND 170MPH. FBC RESIDENTIAL 301.2. PLEASE | | | USE 170MPH OR IF ANOTHER WIND SPEED BETWEEN 160MPH AND | | | 170MPH IS USED, PROVIDE INFORMATION REGARDING HOW THE | | | WIND SPEED WAS DETERMINED. | | | | | | 2. 9" SPACING DOES NOT MEET MINIMUMS IN PRODUCT | | | APPROVAL FOR OPENINGS 8' AND GREATER, SEE SHEET 6, | | | CONNECTION TYPE 1. | | | | | | 3. SPANS SHOULD EQUAL BLADE LENGTH, SHOULD NOT BE THE | | | SAME AS OPENING SIZE FOR A WALL MOUNT. PLEASE REVISE | | | INSTALLATION SCHEDULE. | | | | | | 4. PLEASE INCLUDE INFORMATION REGARDING TYPE OF | | | INSTALLATION; KNUCKLE OR LOCK/CENTERMATES IN ORDER TO | | | DETERMINE SHUTTER GLASS SEPARATION REQUIRED, SEE SHEET | | | 5 OF PRODUCT APPROVAL. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-08-13 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-07-27 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2012-07-30 12:16:40 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-05-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-29 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-23 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2012-05-23 10:49:20 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-10 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-01 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2012-05-01 16:26:14 | MISC 1 | | | | | | |
|
|
|