| Plan Review Stops For Permit 12040652 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-06-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-06-05 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-06-05 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-04-30 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-04-30 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2012-04-30 15:06:44 | BUILDING PLAN REVIEW | | | PERMIT:12040652 | | | ADD: 7422 S DIXIE HWY | | | CONT: LANTANA CONSTRUCTION | | | TEL: (561)312-3600 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET 1 PLEASE SEE NEW 2010 ACCESSIBILITY CODE AND | | | FIGURE 604.8.1.6 WHEELCHAIR ACCESSIBLE TOILET | | | COMPARTMENT IN NEW CONSTRUCTION. THE MINIMUM DIMENSIONS | | | ARE 84 1/2 " X 60" WITH THE WATERCLOSET AND LAV LOCATED | | | ON THE 84 1/2" WALL. THE LAV CAN NOT OVER LAP INTO THE | | | CLEAR FLOOR SPACE FOR THE WATER CLOSET.SEE FIGURE | | | 604.3.1. | | | | | | 2) NEW TO THE 2010 ACCESSIBILITY CODE GRAB BARS ARE NO | | | LONGER MEASURED TO THE CENTER LINE BUT TO THE TOP OF | | | THE BAR PER SECTION 604.8.1.5/ 609.4 THE TOP OF THE | | | GRIPPING SURFACE 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-05-30 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-30 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-30 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-05-02 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-02 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-02 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
ddaniels |
Date |
2012-05-15 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2012-05-15 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-06-14 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-06-14 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-05-29 |
Time |
17:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-05-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-23 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-04-25 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-06-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-06-05 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-06-05 |
Time |
17:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-05-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-23 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-23 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2012-05-23 09:05:11 | PLANS DENIED | | | 1) PROVIDE FRESH AIR CALCULATIONS WITH THE PLANS. | | | PER TABLE 403.3 2010 FBC (M) | | | 2) REFER TO SECTION 503.2.4.4 SHUTOFF DAMPERS | | | 2010 FLORIDA ENERGY CODE | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-06-14 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-06-14 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-06-14 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2012-05-04 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-05-04 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-05-04 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2012-05-04 15:03:27 | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | PLEASE SEE BUILDING REVIEW NOTES BELOW: | | | | | | 1) SHEET 1 PLEASE SEE NEW 2010 ACCESSIBILITY CODE AND | | | FIGURE 604.8.1.6 WHEELCHAIR ACCESSIBLE TOILET | | | COMPARTMENT IN NEW CONSTRUCTION. THE MINIMUM DIMENSIONS | | | ARE 84 1/2 " X 60" WITH THE WATERCLOSET AND LAV LOCATED | | | ON THE 84 1/2" WALL. THE LAV CAN NOT OVER LAP INTO THE | | | CLEAR FLOOR SPACE FOR THE WATER CLOSET.SEE FIGURE | | | 604.3.1. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2012-05-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2012-05-01 |
Time |
12:17 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2012-05-01 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2012-05-01 12:18:15 | INTERIOR WORK ONLY, LESS THAN 50% STRUCTURE VALUE PAST | | | YEAR |
|
|