Plan Review Details - Permit 12040599
Plan Review Stops For Permit 12040599
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-06-11 Cont ID  
Sent By shill Date 2012-06-11 Time 08:47 Rev Time 0.00
Received By shill Date 2012-06-11 Time 08:47 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-05-14 Cont ID  
Sent By shill Date 2012-05-14 Time 12:42 Rev Time 0.00
Received By shill Date 2012-05-10 Time 13:43 Sent To  
Notes
2012-05-14 13:08:39****CORRECTIONS****
 ****REVISED COMMENT LIST****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. FAC61G15-23.001, THE SEAL IS TO INCLUDE THE WORD
 "LICENSE." USE OF THE WORD "CERTIFICATE" HAS NOT BEEN
 ACCCEPTABLE TO FBPE EFFECTIVE JANUARY 1, 2006 PURSUANT
 TO A RULE CHANGE EFFECTIVE FEBRUARY 5, 2004.
  
 2. FAC61G15-23.002(1), ENGINEER SHALL SIGN BY HAND THE
 LICENSEE'S HANDWRITTEN SIGNATURE (FACSIMILES ARE NOT
 ACCEPTABLE). IT APPEARS THAT THE SIGNATURE ON THE TWO
 SETS OF PLANS ARE PHOTOCOPIES.
  
 3. PROPOSED IMPROVEMENT'S RESISTANCE TO DESIGN
 PRESSURES, UPLIFT AND LATERAL, ARE NOT CLEAR. THE PLAN
 STATES THAT THE SOLAR UNITS ARE NOT COMPONENTS AND
 CLADDING, AND REFERS TO A WEBSITE. THE WEBSITE APPEARS
 TO SPECIFY COMPONENT AND CLADDING PRESSURES. PLEASE SEE
 FBC RESIDENTIAL 301.2.1.1.3 AS IT APPEARS THAT
 PRESSURES SHOULD BE DETERMINED USING ROOFTOP STRUCTURES
 METHOD IN ASCE7-10 CHAPTER 29 RATHER THAN COMPONENTS
 AND CLADDING ASCE7-10 CHAPTER 30. CALCULATIONS MAY BE
 REQUIRED.
  
 4. PLAN STATES THAT "COLLECTOR INSTALLATION STANDARD
 FLUSH W/ROOF" BUT ALSO STATES IN OTHER TEXT THAT THE
 COLLECTORS CAN BE TILTED. CLARIFY INSTALLATION METHOD
 AND AMOUNT OF TILT PERMITTED SO THAT COMPLIANCE WITH
 FBC RESIDENTIAL 301.2.1.1.3, LATERAL LOADS, CAN BE
 DETERMINED.
  
 5. ENGINEERING PROVIDED IS GENERIC. TO SHOW DEMONSTRATE
 CODE COMPLIANCE AND TO FACILITATE INSPECTIONS, PLEASE
 PROVIDE THE FOLLOWING INFORMATION:
  
 DISTANCE FROM SOLAR PANEL(S) TO ROOF EDGE AND RIDGE
 STRAP MATERIAL
 STRAP ANCHOR SPACING AND FASTENER PROPOSED
 FLUSH MOUNT OR TILT UP - IF TILT UP, PROVIDE DIMENSION
 OF RISE
  
 6. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB, VALUE
 TOO LOW, FBC 108.3.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-26 Cont ID  
Sent By shill Date 2012-04-26 Time 18:23 Rev Time 0.00
Received By shill Date 2012-04-26 Time 18:23 Sent To  
Notes
2012-04-26 18:33:02****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. FBC RESIDENTIAL 301.2.1.1, PER ASCE7-10 REVISE THE
 FOLLOWING:
  
 INCLUDE RISK CATEGORY IN DESIGN CRITERIA
 REVISE TO EXPOSURE C
 IF THIS IS RISK CATEGORY 1, WIND SPEED SHOULD BE 152;
 RISK CATEGORY II IS 164.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-06-13 Cont ID  
Sent By lwagner Date 2012-06-13 Time 09:51 Rev Time 0.00
Received By lwagner Date 2012-06-11 Time 08:52 Sent To  
Notes
2012-06-11 08:52:17RESUB VIA MAIL, ROUTED TO LW DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-04-26 Cont ID  
Sent By shill Date 2012-04-26 Time 18:33 Rev Time 0.00
Received By shill Date 2012-04-24 Time 12:44 Sent To  
Notes
2012-04-25 12:44:47TO PLUMBING < $5K

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-06-13 Cont ID  
Sent By lwagner Date 2012-06-13 Time 09:17 Rev Time 0.00
Received By lwagner Date 2012-06-13 Time 09:17 Sent To  
Notes
2012-06-13 09:17:23RE-STAMP

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-04-26 Cont ID  
Sent By lwagner Date 2012-04-26 Time 12:17 Rev Time 0.00
Received By lwagner Date 2012-04-26 Time 10:39 Sent To B
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved