| 2012-04-24 10:23:36 | BUILDING PLAN REVIEW |
| | PERMIT: 12040421- UNIT 910 |
| | 12040586- UNIT 912 |
| | ADD:319 CLEMATIS ST |
| | CONT: RIELLY CONSTRCUCTION |
| | TEL: (561)262-6876 |
| | |
| | 2010 FLORIDA BUILDING CODE W/ |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | NOTE: PLANS INDICATE A NEW TENANT SEPERATION WALL, 2 |
| | PERMITS WERE CREATED FOR UNITS ON EACH SIDE OF THE WALL |
| | FOR HISTORY OF THE UNIT (INDICATION OF WHEN THIS UNIT |
| | WAS CREATED) AND LOGGING IN OF INSPECTION RESULTS. |
| | |
| | 1) NEITHER THE LS NOR A-1.0 SHEET PROVIDE WALL |
| | IDENTIFICATION TAGS IDENTIFYING THE WALL TYPE TO BE |
| | INSTALLED. SHEET A-3.0 DETAIL-A PARTITION DETAILS DO |
| | NOT INDENTIFY WHERE THESE WALLS TYPES WILL BE |
| | INSTALLED? 106.3.5.1.1(4) FIRE SEPERATION WALLS, |
| | 709.6(1) ALSO SEE EXCEEPTION #1? |
| | |
| | 2) PROVIDE COMPLIANCE WITH: 2010 FBC-B 712.6 FIRE |
| | WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS |
| | AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE |
| | PROTECTED OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY |
| | IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER |
| | ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. SUCH |
| | IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING |
| | AND IN CONCEALED SPACES. SUGGESTED WORDING FOR FIRE AND |
| | SMOKE BARRIERS: "FIRE AND SMOKE BARRIER - PROTECT ALL |
| | OPENINGS." |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |