Plan Review Details - Permit 12040574
Plan Review Stops For Permit 12040574
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2012-05-04 Cont ID  
Sent By jnguyen Date 2012-05-04 Time 12:21 Rev Time 0.00
Received By jnguyen Date   Time   Sent To  
Notes
2012-05-04 12:21:16I TOUCH BASED WITH THE PROPERTY OWNER OF PCN#
 74424301020000490, 3308 45TH STREET HOLDINGS LLC
 ([email protected] & 561-681-6810) ABOUT OUR
 ADDRESSING POLICY, SPECIFICALLY SECTIONS 1.1 & 1.3
 (BANNING DUPLICATE ADDRESSES & THE REQUIREMENT THAT
 EACH UNIT/STRUCTURE HAVE ITS OWN UNIQUE NUMERICAL
 ADDRESS). IN UNDERSTANDING THAT THERE'S A DOMINO
 EFFECT, I HAVE AGREED TO BE FLEXIBLE BY ACCOMMODATING
 GLEN BEFORE THESE ADDRESSING CHANGES OFFICIALLY TAKE
 PLACE. HE WILL COORDINATE WITH HIS BUSINESS TENANTS IN
 THE OTHER LEASE SPACES AT: 3308 45TH ST # 100B, 3308
 45TH ST BLDG 200 & 3308 45TH ST BLDG 300 TO DETERMINE A
 MUTUALLY AGREED UPON FUTURE SCHEDULED DATE TO
 OFFICIALLY PROCEED WITH THESE PROSPECTIVE ADDRESSING
 CHANGES (LIKELY WITHIN THESE NEXT TWO MONTHS). THE
 PRIMARY ADDRESS OF 3308 45TH ST # 100A (WEST UNIT OF
 THE NORTHEAST INTERCONNECTED BUILDING) WILL CHANGE TO
 3308 45TH ST. IN ADDITION, THE OTHER THREE SECONDARY
 ADDRESSES WILL CHANGE FROM: 3308 45TH ST # 100B TO 3300
 45TH ST (EAST UNIT OF THE NORTHEAST INTERCONNECTED
 BUILDING), 3308 45TH ST BLDG 200 TO 3312 45TH ST
 (NORTHWEST BUILDING) & 3308 45TH ST BLDG 300 TO 3320
 45TH ST (SOUTHWEST BUILDING). IN THE MEANTIME, I HAVE
 PASSED THE STATUS OF THIS PERMIT. HOWEVER, STILL BE
 AWARE THAT THE ADDRESSING CHANGES WILL EVENTUALLY
 OCCUR--JUST NOT YET IMMEDIATELY. THE PLANS & THEIR
 ASSOCIATED DOCUMENTS HAVE BEEN RETURNED TO THE B7 BOX
 DOWNSTAIRS.
  
 JOHN NGUYEN
 GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 PUBLIC UTILITIES DEPARTMENT
 OFFICE: (561) 822-1239
 FAX: (561) 822-1249
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-05-18 Cont ID  
Sent By jwitmer Date 2012-05-18 Time 10:45 Rev Time 0.00
Received By jwitmer Date 2012-05-18 Time 09:15 Sent To  
Notes
2012-05-18 10:42:23BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) CHANGED SWING OF EXTERIOR DOOR WILL REQUIRE A
 PRODUCT APPROVAL.
  
 2) PROVIDE ACCESSIBLE RAMP DETAILS
  
 3) PRE-FABRICATED CANOPY NO ENGINEERING WAS SUBMITTED
 REQUIRES A SEPERATE PERMIT.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-30 Cont ID  
Sent By jwitmer Date 2012-04-30 Time 11:59 Rev Time 0.00
Received By jwitmer Date 2012-04-30 Time 11:20 Sent To  
Notes
2012-04-30 14:11:19BUILDING PLAN REVIEW
 PERMIT: 12040574
 ADD: 3308 45TH ST UNIT 100B
 CONT: CALDWELL BUILDERS INC.
 TEL: (561)644-4904
  
 2010 FLORIDA BUILDING CODE W/
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1A) DISCREPANCY: THE PERMIT APPLICATION INDICATES THE
 DESCRIPTION OF WORK TO BE BUILDING A FIRE WALL DIVIDING
 THE WAREHOUSE. THE TERM FIRE WALL IN SECTION 2010 FBC-B
 706.1. FOR THE PURPOSES OF DETERMINING HEIGHT AND AREA
 IN ACCORDANCE WITH TABLE 503, FIRE WALLS DIVIDING
 BUILDINGS INTO SEPARATE BUILDINGS SHALL PROVIDE A
 4-HOUR FIRE-RESISTANCE RATING. THE EXTENT AND LOCATION
 OF SUCH FIRE WALLS SHALL PROVIDE A COMPLETE SEPARATION.
 WHERE A FIRE WALL ALSO SEPARATES OCCUPANCIES THAT ARE
 REQUIRED TO BE SEPARATED BY A FIRE BARRIER WALL, THE
 MOST RESTRICTIVE REQUIREMENTS OF EACH SEPARATION SHALL
 APPLY.
  
 WHERE AS THE PLANS SHEET 1 INDICATES THE WALL TO BE A
 1-HOUR RATED PARTITION WHICH MAKES IT APPREAR TO BE A
 TENANT SEPERATION WALL. FOR TTHE PURPOSES OF THIS
 REVIEW IT WILL BE TAKEN AS A TENANT SEPERATION WALL.
 PLEASE NOTE IF IT IS TO BE A TENANT SEPERTION WALL THE
 CONTRACTOR WILL NEED TO COME IN AND REDIFINE THE WALL
 TYPE NOT A FIRE WALL BUT A TENANT SEPERATION WALL.
  
 1B) ADDRESSING WILL NEED TO REVIEW PLANS TO BE ABLE TO
 PROVIDE A ADDRESS FOR BOTH UNITS, 106.1.1 * .
 CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT CLARITYY TO
 INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED. CONTACT PERSON: JOHN NGUYEN 822-1239.
  
 1C) ONCE ADDRESSING HAS PROVIDED A CORRECT ADDRESS FOR
 EACH UNIT THTTE CONTRACTOR WILL NEED TO APPLY FOR A
 PERMIT FOR EACH TENNANT SPACE AND THE MONIES (PERMIT
 FEES) BE SPLIT BETWEEN THE TWO UNITS ACCORDING TO THE
 AMOUNT OF WORK TO BE COMPLETETED ON EACH SIDE OF THE
 TENANT SEPERATION WALL. 106.1.2*.
  
 2A) SURVEY INDICATES BUILDING 100A & 100 B CONNECTED,
 IS THIS ONE BUILDING ? IF SO PLEASE PROVIDE THE MINIMUM
 BUILDING TYPE, IF FIRE SPRINKLERED OR NOT AND TTHE AREA
 OF PART 100 A & 100B. 2010 FBC-B 106.3.5.1* MINIMUM
 COMMERCIAL PLAN REVIEW (3).
  
 2B) IF THESE ARE TO BE CONSIDERED TWO SEPERATE
 BUILDINGS THEN REVIEW 2010 FBC-B TABLE 602 FIRE
 -RESISTANCE REQUIEMENTS FOR EXTERIOR WALLS BASED ON
 FIRE SEPERATION DISTANCE, PLEASE NOTE THAT THERE IS AN
 ASSUMED PROPERTY LINE BETWEEN THE TWO BUILDINGS CUTTING
 THE ASSUMED PROPERTY LINE BETWEEN THE TWO BUILDINGS IN
 HALF FROM THE 5.7' TO 2.85' FROM A PROPERTY LINE.
 PLEASE INDICATE MINIMUM BUILDING TYPE AND WALL RATING
 FOR OCCUPANCY TYPE.
  
 2C) PLEASE REVIEW 2010 FBC-B TABLE 705.8 ALLOWABLE
 AREAS OF OPENINGS BASED ON FIRE SEPERATION AND DEGREE
 OF OPENING PROTECTION. LESS THAN 3'-0" NOT PERMITTED.
  
 3A) SHEET A-2 INDICATES A HEADER AND DOOR JAMB DETAIL
 WITH THE A # 5 REBAR VERTICALLY AND 1 # 5 HORIZONTALLY
 OVER THE DOOR. THE PLANS ARE INSUFFICIENT IN DETAIL HOW
 THE STEEL REINFORCING IS TO BECOME PART OF THE (MWFRS)
 MAIN WIND FORCE RESISTING SYSTEM, PLANS LACK CONNECTION
 OF STEEL RE-INFORCING WITH THTE FOOTER/ SLAB OR THE
 BEAM ABOVE. FBC-B 2107.3/ ACI 530.
  
 3B) SHEET A-2 NEW DOOR OPENING DETAIL FOR TOP OF DOOR
 INDICATES THTE USE OF ONE # 5 REBAR, WITH A CONCRETE
 POURED HEADER, REINFORCING STEEL PLACED IN THE CENTER
 OF A CONCRETE BEAM DOES NO GOOD IT IS IN NEITHER
 COMPRESSION OR TENSION. ACI 530 7.5.3.1 SHEAR
 REINFORCEMENT SHALL BE PROVIDED PARALLEL TO THE
 DIRECTION OF APPLIED SHEAR FORCE. SPACING OF SHEAR
 REINFORCEMENT SHALL NOT EXCEED TTHE LESSER OF D/2 OR 48
 INCHES. EITHER PROVIDE A TRUE BEAM OR PROVIDE A LINTEL
 WHICH WILL CARRY THE APPROPRIATE LOADS. IF LINTEL IS
 CONSIDERED PROVIDE LOADING CHARTS.
  
 4) SHEET A-1 PLEASE PROVIDE ADDITIONAL INFORMATION TO
 DOOR LANDING SECTION, IT IS NOT CLEAR TO WHICH SIDE IS
 THE EXTERIOR AND INTERIOR. PLANS DO NOT INDICATE WHERE
 THE THE ACCESSIBLE ENTRANCE WOULD BE LOCATED? 2010
 FBC-B 11-303.1-4. CHANGE IN GRADE.
  
 5) PLANS ARE MISSING PRESSURES FOR THE NEW OPENINGS
 FBC-B 1609.
  
 6) CONTRACTOR HAS NOT SUPPLIED PRODUCT APPROVAL FOR NEW
 DOOR OPENINGS COMPONENTS & CLADDING 1609, RULE 9N-3
 (31)(A) EXTERIOR DOORS.
  
 7) FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC...
 WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE PRODUCT
 WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 8) SHEET A-1 INDICATES THE TENANT SEPERATION WALL BE
 BUILT PER UL DESIGN U 425 BUT THE LISTING IS NOT
 PROVIDED. PLANS INDICATE LATERAL BRACING & FASTENED TO
 TRACK COMPLING WITH UL# U425? ADDITIONAL INFORMATION
 REQUIRED 106.1.2 & FBC-B 709.1(6).
  
 9) PLEASE PROVIDE EXIT LIGHTING FOR THE NEWLY FORMED
 TENANT SPACE FBC-B 1006.3.
  
 10)PLEASE COMPLY WITH : FBC-B 712.6 FIRE WALLS, FIRE
 BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE
 PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY
 IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER
 ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. SUCH
 IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING
 AND IN CONCEALED SPACES. SUGGESTED WORDING FOR FIRE AND
 SMOKE BARRIERS: "FIRE AND SMOKE BARRIER - PROTECT ALL
 OPENINGS."
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-05-17 Cont ID  
Sent By rlecky Date 2012-05-17 Time 08:57 Rev Time 0.00
Received By rlecky Date 2012-05-17 Time 08:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-05-07 Cont ID  
Sent By rlecky Date 2012-05-07 Time 11:42 Rev Time 0.00
Received By rlecky Date 2012-05-07 Time 11:10 Sent To  
Notes
2012-05-07 11:42:2312040574
 3308 45TH ST. #100B
 INTERIOR RENOVATION
  
 VERIFY THE ELECTRICAL SERVICE MAINS FOR THIS BUILDING
 ARE SIX OR LESS AND GROUPED IN ONE LOCATION. CLARIFY
 THE ELECTRICAL RISER PLAN TO SHOW ALL METERS,
 GROUNDING, MAIN DISCONNECTS AND PANEL BOARDS FOR THE
 WHOLE BUILDING.
 NEC 230.2, 230.71, 230.72
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-05-23 Cont ID  
Sent By ddaniels Date 2012-05-23 Time 16:51 Rev Time 0.00
Received By ddaniels Date 2012-05-23 Time 16:51 Sent To  
Notes
2012-05-23 16:54:025/23/2012 PLANS REVIEWED BY FIRE ***APPROVED***
 PENDING ADDRESSING COMMENTS

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-04-24 Cont ID  
Sent By wjolin Date 2012-04-24 Time 11:17 Rev Time 0.00
Received By wjolin Date 2012-04-24 Time 10:20 Sent To  
Notes
2012-04-24 11:17:433308 45TH STREET - #100B
 PERMIT #12040574
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 INDICATE THE REASON FOR INSTALLING A FIRE RATED BARRIER
 TO DIVIDE THE WAREHOUSE SPACE.
  
 EACH NEW SMOKE OR FIRE-RATED WALL/BARRIER SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE/SMOKE BARRIER-PROTECT ALL OPENINGS. CHARACTERS
 SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN
 WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15
 FEET ON CENTER.
  
 PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY SHALL
 BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE. PROVIDE
 DETAILS FOR FIRE SEALANT AND FOR PROTECTING
 THROUGH-PENETRATIONS.
  
 THE TWO NEW DOORS INSTALLED ON SHEET 2 DO NOT HAVE EXIT
 SIGNS OR EMERGENCY LIGHTS. ARE THESE INTENDED TO BE
 USED AS EXIT DOORS?
  
 ONE OF THE NEW DOORS CREATES AN UNPROTECTED OPENING
 WITHIN 10 FEET OF THE ADJACENT BUILDING. CONFIRM THIS
 DOOR DOES NOT NEED TO HAVE A FIRE RESISTANCE RATING AND
 DOOR CLOSER.
  
 PROVIDE HANDRAIL DETAILS AS HANDRAILS ARE REQUIRED ON
 BOTH SIDES OF THE STAIR. HANDRAILS SHALL BE LOCATED NOT
 LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES ABOVE
 THE SURFACE OF THE TREAD, MEASURED VERTICALLY TO THE
 TOP OF THE RAIL FROM THE LEADING EDGE OF THE TREAD.
 HANDRAIL ENDS SHALL BE RETURNED TO THE WALL OR FLOOR OR
 SHALL TERMINATE AT NEWEL POSTS. HANDRAIL CROSS SECTION
 SHALL HAVE A DIAMETER OF NOT LESS THAN 1.25 INCHES AND
 NOT MORE THAN 2 INCHES.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-05-24 Cont ID  
Sent By shill Date 2012-05-24 Time 13:57 Rev Time 0.00
Received By shill Date 2012-05-16 Time 14:29 Sent To  
Notes
2012-05-16 14:29:21B7

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-15 Cont ID  
Sent By lmartine Date 2012-05-10 Time 16:47 Rev Time 0.00
Received By lmartine Date 2012-04-23 Time 10:00 Sent To  
Notes
2012-04-24 10:00:39SENT TO B7 FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 2 Status N Date 2012-05-17 Cont ID  
Sent By lwagner Date 2012-05-17 Time 14:39 Rev Time 0.00
Received By lwagner Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-05-02 Cont ID  
Sent By lwagner Date 2012-05-02 Time 15:20 Rev Time 0.00
Received By lwagner Date 2012-05-02 Time 15:20 Sent To  
Notes
2012-05-02 15:24:36FBC PLUMBING REVIEW #1
  
 IF THE SOUTH PORTION FF THE BUILDING IS STORAGE IT WILL
 REQUIRE PLUMBING FACILITIES PER PLUMBING 403.1
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status P Date 2012-05-10 Cont ID  
Sent By lfranco Date 2012-05-10 Time 10:11 Rev Time 0.00
Received By lfranco Date 2012-05-10 Time 10:11 Sent To  
Notes
2012-05-10 10:12:21PLANNING: ***** *ZONING REVIEW NOT REQUIRED: INTERIOR
 WORK ONLY AND THE VALUE OF PROPOSED WORK DOES NOT
 EXCEED 50% OF THE IMPROVEMENT VALUE. *****