Plan Review Details - Permit 12040569
Plan Review Stops For Permit 12040569
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2012-09-13 Cont ID  
Sent By shill Date 2012-09-13 Time 09:12 Rev Time 0.00
Received By shill Date 2012-09-13 Time 09:12 Sent To FIRE
Notes
2012-09-13 09:13:39****PROVISO****
 ****ISSUED AT CONTRACTOR'S RISK****
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PROVIDE ORIGINAL SIGNED AND SEALED A1.0, LIFE SAFETY
 PLAN, AT INSPECTION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2012-09-12 Cont ID  
Sent By shill Date 2012-09-12 Time 13:25 Rev Time 0.00
Received By shill Date 2012-09-12 Time 13:25 Sent To FIRE
Notes
2012-09-12 13:28:11****PROVISO****
 ****ISSUED AT CONTRACTOR'S RISK****
 ****REVISION REQUIRED****
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. SEE PREVIOUS LIST, OCCUPANCY CLASSIFICATION AND
 DESIGNATION AS CHANGE OF OCCUPANCY (WHICH APPEARS TO BE
 APPLICABLE) IS TO BE INCLUDED ON THE PLAN.
  
 2. THE ADDRESS ON THE PLAN IS SYNNEX RACKING, AND THE
 PLAN IS LABELED A "LIFE SAFETY/RACKING PLAN." PLEASE
 REVISE; REMOVE THE JOB WHICH IS LOCATED IN MIAMI AND
 INCLUDE THE ADDRESS, JOB NAME FOR THIS PROJECT.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2012-08-17 Cont ID  
Sent By shill Date 2012-08-17 Time 07:45 Rev Time 0.00
Received By shill Date 2012-08-13 Time 17:19 Sent To  
Notes
2012-08-17 09:00:55****CORRECTIONS****
 ****REVISED PER EMAIL FROM ENGINEER 8/22/12****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PLEASE INCLUDE OCCUPANCY CLASSIFICATION. CLASSROOMS
 ARE EDUCATIONAL, FBC 305. CURRENT PLAN SHOWS
 CLASSROOMS. PER ENGINEER, THIS IS DAY CARE ONLY.
  
 IF THIS IS EDUCATIONAL, THIS IS A CHANGE OF OCCUPANCY.
 REVISE PLAN TO INCLUDE THIS INFORMATION, SEE ALSO FBC
 443 REGARDING ADDITIONAL REQUIREMENTS FOR EDUCATIONAL
 OCCUPANCY.
  
 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED,
 FAC9N-3. THE NOA REFERENCED ON THE PLAN (10-1203.03) IS
 SUPERSEDED BY ANOTHER NOA; PROVIDE CURRENT PRODUCT
 APPROVAL. PLEASE MARK OPTIONS PROPOSED ON THE PRODUCT
 APPROVAL.
  
 3. PROVIDE A REASONABLE VALUE FOR THE PROPOSED WORK AND
 FOR WORK DONE PREVIOUSLY WITHOUT PERMIT WHICH WILL BE
 INCLUDED UNDER THE SCOPE OF THIS PERMIT, FBC 109.3.
  
 4. FBC ACCESSIBILITY 202.3, 202.4, PROVIDE INFORMATION
 REGARDING COMPLIANCE OF THE ACCESSIBLE PATH OF TRAVEL
 AND THE ELEMENTS LISTED.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-06-28 Cont ID  
Sent By shill Date 2012-06-28 Time 18:52 Rev Time 0.00
Received By shill Date 2012-06-28 Time 18:52 Sent To  
Notes
2012-06-28 18:53:18****CORRECTIONS****
 ****PLAN REVIEW IN PROGRESS***
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. CONFIRM THAT THIS FACILITY HAS A FIRE ALARM SYSTEM
 AS THIS NO LONGER FALLS UNDER THE EXCEPTION, FBC 436.7.
  
 2. ENGINEER WHO SIGNED AND SEALED THE PLAN NO LONGER
 HAS A LICENSE TO PRACTICE ENGINEERING IN FLORIDA, SEE
 WWW.MYFLORIDALICENSE.COM. PLEASE SUBMIT PLANS DESIGNED
 BY A LICENSED DESIGN PROFESSIONAL.
  
 3. PROVIDE A SITE PLAN SHOWING LOCATION OF AFFECTED
 WALL AND DISTANCE TO PROPERTY LINE OR OTHER STRUCTURES,
 FBC 602, 705. MORE INFORMATION MAY BE REQUIRED.
  
 4. PROVIDE OCCUPANT LOAD AND SQUARE FOOT AREA FOR EACH
 ROOM, FBC 1037.2.
  
 5. SEE FBC 709.1, RECONFIGURED SPACES, NO MECHANICAL
 INFORMATION PROVIDED, PLEASE ADDRESS. MECHANICAL REVIEW
 WILL BE REQUIRED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-05-07 Cont ID  
Sent By shill Date 2012-05-04 Time 16:07 Rev Time 0.00
Received By shill Date 2012-05-04 Time 15:44 Sent To FIRE
Notes
2012-05-07 10:06:14****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. OUR RECORDS DO NOT SHOW INTERIOR PARTITION WALLS AS
 SHOWN ON THE PLAN. ORIGINAL BUILDING PLANS SHOW A LARGE
 OPEN SPACE, AND OUR RECORD DEPARTMENT WAS UNABLE TO
 LOCATE A RENOVATION PERMIT FOR THIS ADDRESS.
  
 PLEASE SEE FBC 1037 REGARDING MEANS OF EGRESS
 REQUIREMENTS, AND ALSO PLEASE SEE FBC 1037.6 REGARDING
 MEANS OF EGRESS FROM EACH SPACE.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-08-20 Cont ID  
Sent By rlecky Date 2012-08-20 Time 14:33 Rev Time 0.00
Received By rlecky Date 2012-08-20 Time 14:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2012-09-13 Cont ID  
Sent By ddaniels Date 2012-09-13 Time 15:22 Rev Time 0.00
Received By ddaniels Date 2012-09-13 Time 15:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2012-08-25 Cont ID  
Sent By wjolin Date 2012-08-25 Time 20:56 Rev Time 0.00
Received By wjolin Date 2012-08-25 Time 20:43 Sent To B
Notes
2012-08-25 20:57:14SEE BUILDING DEPT COMMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-06-21 Cont ID  
Sent By rferguso Date 2012-06-21 Time 14:02 Rev Time 0.00
Received By rferguso Date 2012-06-21 Time 14:02 Sent To B
Notes
2012-06-21 14:04:41DELIVERED TO SAMANTHA

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-05-07 Cont ID  
Sent By ddaniels Date 2012-05-07 Time 12:00 Rev Time 0.00
Received By ddaniels Date 2012-05-07 Time 10:08 Sent To Z
Notes
2012-05-07 10:16:19FIRE DEPARTMENT REVIEW ****DENIED***
 ADDRESS: 391 VALLEY FORGE ROAD
 PERMIT # 12040569
 CONTRACTOR: ALLCRETE CONSTRUCTION
 PHONE: (305) 592-6255
  
  
  
 1.) SPECIAL MEANS OF EGRESS FEATURES
  
 WHERE THE ROOM OR SPACE COMPLIES WITH THE FOLLOWING:
  
 (A) DOORS SHALL EXIST THAT ALLOW TRAVEL BETWEEN
 ADJACENT ROOMS.
  
 (B) DOORS USED TO TRAVEL FROM ROOM TO ROOM SHALL
 PROVIDE ON OF THE FOLLOWING:
 I. DIRECT ACCESS TO EXIS IN BOTH DIRECTIONS
 II. DIRECT ACCESS TO AN EXIT IN ONE DIRECTION AND TO A
 SEPARATE SMOKE COMPARTMENT THAT PROVIDES ACCESS TO
 ANOTHER EXIT IN THE OTHER DIRECTION
  
 (C) THE CORRIDOR SHALL BE SEPARATED FROM THE ROOMS BY A
 WALL THAT RESISTS THE PASSAGE OF SMOKE, AND ALL DOORS
 BETWEEN THE ROOMS AND THE CORRIDOR SHALL BE SELFCLOSING
 IN ACCORDANCE WITH 7.2.1.8 OF NFPA 101 CHAPTER 7
 SECTION 5 A-F.
  
 (D) THE LENGTH OF TRAVEL TO EXITS ALONG SUCH PATHS
 SHALL NOT EXCEED 150FT.
  
 (E) EACH COMMUNICATING DOOR SHALL BE MARKDED IN
 ACCORDANCE WTIH SECTION 7.10.
  
 (F) NO LOCKING DEVICE SHALL BE PERMITTED ON THE
 COMMUNICATING DOORS.
  
  
  
 DERRICK L. DANIELS, BATTALION CHIEF / FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 OFFICE OF THE FIRE MARSHAL
 (561) 805-6722
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By shill Date 2012-09-12 Time 15:39 Sent To  
Notes
2012-09-12 15:39:17ROUTED TO FIRE DESK FOR DD REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-08-28 Cont ID  
Sent By shill Date 2012-08-28 Time 09:49 Rev Time 0.00
Received By shill Date 2012-07-26 Time 14:58 Sent To  
Notes
2012-07-26 14:58:23SENT TO SAMANTHA'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-06-29 Cont ID  
Sent By shill Date 2012-06-29 Time 17:14 Rev Time 0.00
Received By shill Date 2012-06-20 Time 13:42 Sent To  
Notes
2012-06-20 13:42:39TO FIRE
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-09 Cont ID  
Sent By eschneid Date 2012-05-09 Time 16:16 Rev Time 0.00
Received By eschneid Date 2012-04-23 Time 10:56 Sent To  
Notes
2012-05-09 16:17:54FILED UNDER SMALL BIN "A"
2012-05-04 16:07:445/4 TO FIRE
  
2012-04-24 10:49:48SENT TO BUILDING UNDER $5000 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2012-08-21 Cont ID  
Sent By hmoser Date 2012-08-21 Time 12:24 Rev Time 0.00
Received By hmoser Date 2012-08-21 Time 12:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2012-09-12 Cont ID  
Sent By lwagner Date 2012-09-12 Time 12:17 Rev Time 0.00
Received By lwagner Date 2012-09-11 Time 13:25 Sent To  
Notes
2012-09-11 13:26:19FACILITY HAS EXISTING DRINKING FOUNTAIN AND LAUNDRY TUB
 LISTED IN REVIEW #1

Review Stop P PLUMBING
Rev No 1 Status N Date 2012-09-12 Cont ID  
Sent By lwagner Date 2012-08-20 Time 14:07 Rev Time 0.00
Received By lwagner Date 2012-08-20 Time 08:36 Sent To  
Notes
2012-08-20 13:50:25UPDATED IN REVIEW # 2
  
 FBC EXISTING BUILDING CODE 2010
 FBC ACCESSIBILITY CODE 2010
 FBC PLUMBING CODE 2010 REVIEW #1
 DENIED:
  
 FBC PLUMBING TABLE 403.1
 DAY CARE AND EDUCATIONAL OCCUPANCIES REQUIRE DRINKING
 FOUNTAINS AND A SERVICE SINK. THE SUBMITTED PLAN DOES
 NOT SHOW THESE FIXTURES (HEALTH DEPT. REGULATIONS ALSO
 REQUIRE THESE FIXTURES - ARTICLE X #46 & #48).
  
 2. FBC ACCESSIBILITY CODE 2010 211.2 MINIMUM NUMBER. NO
 FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
 602.2 CLEAR FLOOR SPACE. UNITS SHALL HAVE A CLEAR FLOOR
 OR GROUND SPACE COMPLYING WITH 305 POSITIONED FOR A
 FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE
 CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED.
 EXCEPTION: A PARALLEL APPROACH COMPLYING WITH 305 SHALL
 BE PERMITTED AT UNITS FOR CHILDREN'S USE WHERE THE
 SPOUT IS 30 INCHES (760 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND AND IS 3 1/2 INCHES (90 MM) MAXIMUM
 FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS.
  
  
 ****INFORMATIONAL****
 3. FBC 2012 TABLE 1004.1.1
 FROM THE BUILDING REVIEW COMMENTS A CHANGE OF OCCUPANCY
 - EDUCATIONAL OCCUPANCIES ARE 20 S.F. PER OCCUPANT. THE
 TOILET FACILITIES SHOWN WOULD BE SUFFICIENT.
  
 PLEASE SEE THE HEALTH DEPT. WEB SITE FOR REQUIREMENTS:
 HTTP://WWW.PBCHD.COM/PDFS/ENVIRONMENTAL/CHILDCARE/PBCHD
 _RULES_AND_REGULATIONS_GOVERNING_CHILD_CARE_FACILITIES.
 PDF
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  
  
  

Review Stop Z ZONING
Rev No 1 Status N Date 2012-05-09 Cont ID  
Sent By eschneid Date 2012-05-09 Time 16:08 Rev Time 0.25
Received By eschneid Date 2012-05-08 Time 10:28 Sent To  
Notes
2012-05-09 16:09:29VALUE LESS THAN 50% OF STRUCTURE, INTERIOR WORK ONLY.
2012-05-08 10:28:22GIVEN TO ES