Plan Review Details - Permit 12040562
Plan Review Stops For Permit 12040562
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-05-21 Cont ID  
Sent By jwitmer Date 2012-05-21 Time 14:19 Rev Time 0.00
Received By jwitmer Date 2012-05-21 Time 14:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-30 Cont ID  
Sent By jwitmer Date 2012-04-30 Time 11:01 Rev Time 0.00
Received By jwitmer Date 2012-04-30 Time 11:01 Sent To  
Notes
2012-04-30 11:21:00BUILDING PLAN REVIEW
 PERMIT: 12040562
 ADD: 5600 N FLAGLER # PH102
 CONT: L-BOYS BUILDING & DESIGN LLC
 TEL: (561)346-0543
  
 2010 FLORIDA BUILDING CODE W/
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) 106.1.2* ADDITIONAL DATE REQUIRED. THE CONTRACTOR OF
 RECORD TO TAKE RESPNSIBILITY FOR THE DESIGN OF THE
 PLANS, PLEASE PRINT YOUR NAME, SIGN YOUR NAME AND
 LICENSE NUMBER OF YOUR BUSINESS.
  
 2) 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 COMMERCIAL BUILDINGS-
 106.3.5 (9) MATERIALS SHALL BE REVIEWED AND SHALL AT A
 MINIMUM INCLUDE THE FOLLOWING DESIGN CRITERIA:
 (A) STEEL STUDS, & CEILING JOIST: PROVIDE THE SIZE OF
 THE CEILING JOIST, GAUGE, SPACING, CLEAR SPAN IF STRONG
 BACKS ARE GOING TO BE INSTALLED, WHERE AND TYPE OF
 MATERIAL TO BE
 INSTALLED IF STRONG BACKS ARE INSTALLED. PLEASE ALSO
 PROVIDE THE DESIGN CRITERIA FOR DEFLECTION PER FBC-B
 TABLE 1604.3. 2010 FBC-B TABLE 2508.1 STEEL FRAMING FOR
 GYPSUM
 BOARD, & TABLE 2506.2 STEEL STUDS NON LOAD BEARING.
  
 B) PLANS DO NOT PROVIDE THE THICKNESS OF DRYWALL TO BE
 INSTALLED ON THE DROP CEILING THAT IS REPLACING THE
 REMOVED ACOUSTICAL CEILING. 106.3.5((9) GYPSUM BOARD
 AND
 PLASTER.
  
 3) NO ELECTRICAL SHOWN ON PLANS, THE ELECTRICAL
 CONTRACTOR WILL NEED TO DRAW THEIR OWN ELECTRICAL PLANS
 AND MEET THE SAME REQUIREMENTS AS THE DESIGNER OF PLANS
 FOR ELECTRICAL.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-05-17 Cont ID  
Sent By rlecky Date 2012-05-17 Time 11:44 Rev Time 0.00
Received By rlecky Date 2012-05-17 Time 11:44 Sent To B
Notes
2012-05-17 11:45:38TO JM
2012-05-17 11:44:45AN ELECTRICAL PERMIT IS REQUIRED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-05-21 Cont ID  
Sent By jwitmer Date 2012-05-21 Time 14:19 Rev Time 0.00
Received By jwitmer Date 2012-05-16 Time 14:17 Sent To  
Notes
2012-05-16 14:18:08ELECTRIC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-04 Cont ID  
Sent By rlecky Date 2012-05-04 Time 11:57 Rev Time 0.00
Received By rlecky Date 2012-04-23 Time 13:15 Sent To  
Notes
2012-04-24 11:34:28SENT TO B12 SHELF FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 1 Status N Date 2012-04-30 Cont ID  
Sent By eschneid Date 2012-04-30 Time 17:40 Rev Time 0.25
Received By eschneid Date 2012-04-30 Time 17:40 Sent To  
Notes
2012-04-30 17:40:47INTERIOR WORK ONLY, LESS THAN 50% VALUE