Plan Review Details - Permit 12040549
Plan Review Stops For Permit 12040549
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-04-20 Cont ID  
Sent By jwitmer Date 2012-04-20 Time 15:25 Rev Time 0.00
Received By jwitmer Date 2012-04-20 Time 15:25 Sent To  
Notes
2012-04-20 15:27:47BUILDING PLAN REVIEW
 PERMIT: 12040105- BUILDING
 12040549- ROOFING
 ADD: 1003 ALLENDALE RD
 CONT: PEMBERTON BUILDING
 TEL: (561)718-8622
  
 2010 FLORIDA BUILDING CODE W/
 * WEST PALM BEACH AMENDMENTS
  
  
 BUILDING PROVISO:
  
 2010 FBC-B
 ROOF SHINGLES
 1507.2.8
 UNDERLAYMENT APPLICATION.
 FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (17-PERCENT SLOPE) AND UP TO FOUR UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE),
 UNDERLAYMENT SHALL BE TWO LAYERS APPLIED IN THE
 FOLLOWING MANNER. APPLY A MINIMUM 19-INCH-WIDE (483 MM)
 STRIP OF UNDERLAYMENT FELT PARALLEL WITH AND STARTING
 AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE.
 STARTING AT THE EAVE, APPLY 36-INCH-WIDE (914 MM)
 SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19
 INCHES (483 MM), BY FASTENED SUFFICIENTLY TO HOLD IN
 PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT
 INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL. FOR
 ROOF SLOPES OF FOUR UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (33-PERCENT SLOPE) OR GREATER, UNDERLAYMENT
 SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER.
 UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL
 TO AND STARTING FROM THE EAVE AND LAPPED 2 INCHES (51
 MM), FASTENED SUFFICIENTLY TO HOLD IN PLACE.
 DISTORTIONS IN THE UNDERLAYMENT SHALL NOT INTERFERE
 WITH THE ABILITY OF THE SHINGLES TO SEAL.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715