Plan Review Details - Permit 12040542
| Plan Review Stops For Permit 12040542 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-10 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-10 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-04-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-04-27 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-04-27 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2012-04-27 16:18:44 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. WEST PALM BEACH IS IN ASTM E 1996 WIND ZONE 4, FBC | | | RESIDENTIAL 301.2.1.2.1. SEE SHEET 1, ITEM 1, GENERAL | | | NOTES, THIS PRODUCT HAS BEEN TESTED FOR USE IN ZONES 1 | | | THROUGH 3 ONLY (EASTERN METAL SUPPLY PANELS, FL 11964). | | | | | | 2. FOR THE STORM PANELS, SEE SHEET 10. NOTE THAT A .35 | | | FACTOR IS TO BE APPLIED TO ANCHOR SPACING WHEN THE EDGE | | | DISTANCE IS LESS THAN 3.5". | | | | | | 3. SEE SHEET 5 OF THE ACCORDION PRODUCT APPROVAL. | | | PLEASE SPECIFY WHICH INSTALLATION IS PROPOSED; | | | "KNUCKLE" OR "LOCK/CENTERMATE" AND REVISE SHUTTER TO | | | GLASS SEPARATION ON THE INSTALLATION SCHEDULE. | | | | | | 4. SPANS SHOULD EQUAL BLADE LENGTH FOR ACCORDIONS, | | | ANCHOR TO ANCHOR FOR PANELS. PLEASE REVISE AS | | | NECESSARY. UNLESS THE INSTALLATION IS A TRAPPED MOUNT, | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-10 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-01 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2012-05-01 16:53:35 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-04-27 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-04-20 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2012-04-20 16:06:39 | MISC. 1 |
|
|
|