Plan Review Details - Permit 12040534
Plan Review Stops For Permit 12040534
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-06-06 Cont ID  
Sent By jgomez Date 2012-06-06 Time 09:50 Rev Time 0.00
Received By jgomez Date 2012-06-06 Time 09:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-05-15 Cont ID  
Sent By jgomez Date 2012-05-15 Time 17:37 Rev Time 0.00
Received By jgomez Date 2012-05-15 Time 14:55 Sent To  
Notes
2012-05-15 18:02:44RESIDENTIAL (R3) RENOVATION/ALTERATION BUILDING REVIEW
 COMMENTS.
 2010 FLORIDA RESIDENTIAL CODE AND 2010 FBC.
  
 1- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW.
 SCOPE OF WORK SHOWN ON PLANS IS A LOT MORE THAN THE
 SCOPE OF WORK DESCRIBED ON THE PERMIT APPLICATION.
 VALUE NEED TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND THE DESIGN
 PROFESSIONAL FEES. PLEASE UPDATE THE VALUE TO INCLUDE
 ALL WORK SHOWN ON THE PLANS SUBMITTED (EXCEPT FOR THE
 DRIVEWAY, WHICH IS A SEPARATE PERMIT) AS REQUIRED BY
 SEC. 109.3 OF CITY AMENDMENTS TO FBC.
  
 2- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FRENCH DOORS. SUBMIT 2 COPIES. ONLY ONE FLORIDA
 PRODUCT APPROVAL FL14569-R2 WAS SUBMITTED.
  
 B) SINGLE HUNG WINDOWS. NOA 07-0717.05 SUBMITTED WAS
 SUPERSEDED BY MIAMI-DADE. VISIT THE MIAMI-DADE WEBSITE
 AND DOWNLOAD CURRENT NOA. AND, PROVIDE 2 COPIES.
  
 C) GARAGE DOOR AS SHOWN ON PLANS.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED BY THE
 ENGINEER ON PLANS AND DETAILS. PROVIDE ONLY THE COVER
 PAGE AND PAGE SHOWING THE CONNECTOR. THIS APPLIES TO
 THE STRUCTURAL CONNECTORS ONLY.
  
 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS TO FBC.
  
 4- SPECIFY THE DESIGN PRESSURES FOR THE NEW GARAGE
 DOOR. SEC. R301.2.1.4.3.
  
 5- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR THE INSTALLATION OF THE NEW TRELLIS AND WOOD DECKS
 SHOWN ON PLANS. SPECIFY WOOD FRAMING MEMBERS SIZES AND
 CONNECTORS. SEC. 107.2.1.3 CITY AMENDMENTS TO FBC.
  
 6- PLANS NEED TO PROVIDE THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC.
 107.2.1 CITY AMENDMENTS TO FBC.
  
 7- DETAIL 5 ON SHEET S-2: SPECIFY HOW THE EXISTING
 CEILING RAFTERS ARE REINFORCED WHEN CUT TO RECEIVED THE
 NEW (3)2X8 GIRDER. ARE THESE CEILING RAFTERS OR WOOD
 TRUSSES?. AND HOW ARE THEY ATTACHED TO THE NEW GIRDER.
 SEC. 107.2.1.3 CITY AMENDMENTS TO FBC.
  
 8- THIS IA AN ALTERATION LEVEL 3 NOT 2. SEC. 405 OF
 2010 FBC-EXISTING BUILDING. REVISE INFORMATION ON
 SHEETS SP AND D1 AS REQUIRED.
  
 9- SHEET S-2: REVISE CORNER DISTANCE A ON THE WIND LOAD
 SCHEDULE. NOTE ON FIGURE R301.2(7) REQUIRES A=4 FEET IN
 ALL CASES.
  
 IF YOU HAVE ANY QUESTION, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-06-07 Cont ID  
Sent By rlecky Date 2012-06-07 Time 14:49 Rev Time 0.00
Received By rlecky Date 2012-06-07 Time 08:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-05-08 Cont ID  
Sent By rlecky Date 2012-05-02 Time 10:55 Rev Time 0.00
Received By rlecky Date 2012-05-02 Time 09:44 Sent To  
Notes
2012-05-02 12:35:0712040534
 434 32ND STREET
 SFD REMODEL
  
 LOCATE THE ELECTRIC SERVICE, AC DISCONNECTS AND PANEL
 BOARDS ON THE PLAN. NEC 215.5
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
 INDICATE THAT ALL NEW GENERAL PURPOSE BRANCH CIRCUITS
 MUST BE PROTECTED WITH ARC FAULT CIRCUIT INTERRUPTERS.
 2008 NEC 210.12
 THE BATHROOMS REQUIRE A DEDICATED 20 AMP BRANCH
 CIRCUIT. NEC 210.11 (C) (3)
 RECEPTACLES IN BATHROOMS MUST BE GFCI PROTECTED. NEC
 210.8
 A GFCI PROTECTED RECEPTACLE IS REQUIRED OUTSIDE FRONT
 AND BACK. NEC 210.70
 RELOCATED SPA REQUIRES ELECTRICAL BONDING AND GROUND
 FAULT PROTECTION. NEC 680.42, 680.42
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT
 ALREADY EXIST WITHIN THE RESIDENCE. 2010 FBC R314
  
 ROBERT LECKY, CBO
 ELECTRIC PLANS EXAMINER
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2012-06-18 Cont ID  
Sent By fmittner Date 2012-06-18 Time 16:12 Rev Time 0.00
Received By fmittner Date 2012-06-18 Time 16:12 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2012-05-10 Cont ID  
Sent By fmittner Date 2012-05-10 Time 11:25 Rev Time 0.00
Received By fmittner Date 2012-05-10 Time 11:25 Sent To  
Notes
2012-05-10 11:43:31WINDOWS TO MATCH EXISTING AS PER NOTES, INCLUDING CLEAR
 GLASS, WHITE FRAMES AND OGEE MUNTIN PROFILE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-06-18 Cont ID  
Sent By lmartine Date 2012-06-18 Time 16:34 Rev Time 0.00
Received By lmartine Date 2012-05-31 Time 10:17 Sent To  
Notes
2012-06-01 10:18:50SENT TO R3 SHELF FOR REVIEW BY ALL TRADES. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-15 Cont ID  
Sent By jgomez Date 2012-05-15 Time 18:37 Rev Time 0.00
Received By jgomez Date 2012-04-20 Time 07:10 Sent To  
Notes
2012-04-23 07:14:31R01

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-06-06 Cont ID  
Sent By jgomez Date 2012-06-06 Time 13:44 Rev Time 0.00
Received By jgomez Date 2012-06-06 Time 13:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-05-15 Cont ID  
Sent By jgomez Date 2012-05-15 Time 18:32 Rev Time 0.00
Received By jgomez Date 2012-05-15 Time 18:32 Sent To  
Notes
2012-05-15 18:37:18RESIDENTIAL (R3) RENOVATION MECHANICAL REVIEW COMMENTS.
 2010 FLORIDA RESIDENTIAL CODE.
  
 1- NEED TO PROVIDE COMPLETE INFORMATION ON PLANS. NOTE
 #3 DOESN'T PROVIDE ANY INFORMATION. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-06-06 Cont ID  
Sent By jgomez Date 2012-06-06 Time 11:30 Rev Time 0.00
Received By jgomez Date 2012-06-06 Time 11:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-05-15 Cont ID  
Sent By jgomez Date 2012-05-15 Time 18:37 Rev Time 0.00
Received By jgomez Date 2012-05-15 Time 18:37 Sent To  
Notes
2012-05-15 18:40:23RESIDENTIAL (R3) RENOVATION PLUMBING REVIEW COMMENTS.
 2010 FLORIDA RESIDENTIAL CODE.
  
 1- PROVIDE PLUMBING RISER DIAGRAM THAT MATCHES LAYOUT
 SHOWN ON PLANS. SEC. 107.3.5.3(11) CITY AMENDMENTS TO
 FBC.
  
 2- WHERE ARE THE CLOTHES WASHER AND WATER HEATER
 LOCATED?. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 2 Status P Date 2012-06-18 Cont ID  
Sent By fmittner Date 2012-06-18 Time 16:12 Rev Time 0.00
Received By fmittner Date 2012-06-18 Time 16:12 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2012-05-10 Cont ID  
Sent By fmittner Date 2012-05-10 Time 11:24 Rev Time 0.00
Received By fmittner Date 2012-05-10 Time 11:24 Sent To  
Notes
2012-05-10 11:28:34REQUIRES 2 SURVEYS