Plan Review Details - Permit 12040458
Plan Review Stops For Permit 12040458
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-04-18 Cont ID  
Sent By jgomez Date 2012-04-18 Time 10:30 Rev Time 0.00
Received By jgomez Date 2012-04-18 Time 10:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-18 Cont ID  
Sent By jgomez Date 2012-04-18 Time 09:35 Rev Time 0.00
Received By jgomez Date 2012-04-18 Time 09:28 Sent To  
Notes
2012-04-18 09:42:04RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 2010 FLORIDA RESIDENTIAL CODE.
  
 1- FLAT ROOF:
 A) SELECTED ASSEMBLY ON PAGE 34 OF 41 OF NOA 08-0924.14
 SUBMITTED IS LIMITED BY GENERAL LIMITATION #9. THIS
 LIMITATION DOESN'T ALLOW ENHANCED FASTENING TO MEET THE
 DESIGN PRESSURES FOR CORNER AND PERIMETER AREAS AS
 REQUIRED BY SEC. R301.2.1.4.3. NEED TO SELECT ANOTHER
 ASSEMBLY THAT IS LIMITED BY GENERAL LIMITATION #7,
 WHICH ALLOWS ENHANCED FASTENING.
  
 B) PROVIDE SIGNED AND SEALED ENHANCED FASTENING
 CALCULATIONS (RAS 117) AS REQUIRED BY GENERAL
 LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-04-18 Cont ID  
Sent By jgomez Date 2012-04-18 Time 10:30 Rev Time 0.00
Received By jgomez Date 2012-04-18 Time 10:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-04-18 Cont ID  
Sent By jgomez Date 2012-04-18 Time 09:28 Rev Time 0.00
Received By jgomez Date 2012-04-18 Time 09:28 Sent To  
Notes
***NONE***