Plan Review Details - Permit 12040376
Plan Review Stops For Permit 12040376
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-05-04 Cont ID  
Sent By jwitmer Date 2012-05-04 Time 08:05 Rev Time 0.00
Received By jwitmer Date 2012-05-03 Time 15:13 Sent To  
Notes
2012-05-04 08:37:07CHANGED OUT CS1, LS-1, A1 & A3 SHEETS, OK. JW
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-23 Cont ID  
Sent By jwitmer Date 2012-04-23 Time 10:18 Rev Time 0.00
Received By jwitmer Date 2012-04-23 Time 09:41 Sent To  
Notes
2012-04-23 10:55:51BUILDING PLAN REVIEW
 PERMIT: 12040376
 ADD: 319 CLEMATIS ST # 1004
 CONT: CLAY KOHLMEYER
 TEL: (561)719-3429
  
 2010 FLORIDA BUILDING CODE W/
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) 2010 FL EXIST BLDG CODE. THE DESIGNER OF RECORD
 SHALL INDICATE TO WHICH METHOD OF COMPLIANCE THIS PLAN
 WAS DESIGNED. 2010 FL EXIST BLDG CODE 101.5.
  
 2) CS-1 PROJECT DETAILS INDICATE THIS BUILDING TO BE 10
 STORIES, TYPE I-B, SPRINKLERED AND UNPROTECTED!
 PLEASE REVIEW 2010 FBC-B TABLE 603 INTERIOR BEARING
 WALLS (INTERIOR COLUMNS) 3 HOURS SEE FOOTNOTE A
 ALLOWING A 1 HOUR REDUCTION FOR SUPPORTING 1 STORY OR
 ROOF ABOVE.
 PLANS (COVERSHEET) DO NOT INDICATE PROTECTION OF
 STRUCTURAL ELEMENTS NOR DOES LS-1 OR A-1.0 FOR THE NEW
 PARTITIONS THAT SURROUND THE EXISTING COLUMNS. SHEET
 A-3.0 DOES INDICATE WALL TYPES BUT THE WALLS
 SURROUNDING THE COLUMNS ARE NOT IDENTIFIED WITH ANY
 WALL IDENTIFICATION TAGS.
  
 3) SHEET A-1.0 INDICATES TENANT SEPERATION WALLS TO BE
 RATED THE THE WALL LEGEND BUT WALL TAGS ARE NOT
 PROVIDED IDENTIFYING WHICH WALL APPLICATION LOCATED ON
 SHEET A-3.0 WILL BE CONSTRUCTED? 106.3.5.1.1(4) *. FIRE
 RESISTANT SEPERATIONS.
  
 4) PLANS DO NOT PROVIDE COMPLIANCE WITH 2010 FBC-B
 712.6 FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE
 BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL
 REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE
 EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY
 HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE
 ANY DECORATIVE CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: "FIRE
 AND SMOKE BARRIER - PROTECT ALL OPENINGS."
  
 5) SHEET A-1.0 DOES INDICATE A RECEPTIONIST, NO PLANS
 WERE SUBMITTED INDICATING THE TYPE OF DESK/ COUNTER TO
 BE LOCATED AT THIS LOCATION. COMPLIANCE WITH 2010 FBC-B
 -ACCESSIBILITY CODE 904.4 SERVICE COUNTERS CAN NOT BE
 DETERMINED DURING THIS REVIEW OR IF THEY ARE REQUIRED?
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-04-30 Cont ID  
Sent By jleahy Date 2012-04-30 Time 13:46 Rev Time 0.00
Received By jleahy Date 2012-04-30 Time 13:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2012-05-04 Time   Rev Time 0.00
Received By   Date 2012-05-04 Time   Sent To  
Notes
2012-05-04 10:24:105/04/2012
 319 CLEMATIS STREET
 PERMIT #12040376 REVIEWED BY FIRE (P)
  
 RONALD E. FERGUSON, INTERIM ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
 PHONE #(561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2012-04-24 Cont ID  
Sent By wjolin Date 2012-04-24 Time 11:39 Rev Time 0.00
Received By wjolin Date 2012-04-24 Time 11:19 Sent To  
Notes
2012-04-24 11:23:38319 CLEMATIS STREET
 PERMIT #12040376
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO
 THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION
 DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. ALL
 DEMOLITION AND CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED.
  
 FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF
 THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.
  
 EACH SMOKE OR FIRE-RATED WALL SHALL BE PERMANENTLY
 IDENTIFIED WITH SIGNS OR STENCILING READING FIRE/SMOKE
 BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE AT
 LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH.
 IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON
 CENTER.
  
 SHEET E-2: PLAN INDICATES ONLY ONE HORN/STROBE FIRE
 ALARM DEVICE. ADDITIONAL DEVICES WILL BE NEEDED TO
 COMPLY WITH NFPA 72.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-05-07 Cont ID  
Sent By lmartine Date 2012-05-04 Time 15:56 Rev Time 0.00
Received By lmartine Date 2012-05-03 Time 15:12 Sent To  
Notes
2012-05-03 15:12:54INCOMING SENT TO B-22. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-02 Cont ID  
Sent By hmoser Date 2012-05-02 Time 13:26 Rev Time 0.00
Received By hmoser Date 2012-04-13 Time 08:56 Sent To  
Notes
2012-05-01 12:37:204/30/12
 EXPEDITED

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-05-02 Cont ID  
Sent By hmoser Date 2012-05-02 Time 13:25 Rev Time 0.00
Received By hmoser Date 2012-05-02 Time 12:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2012-04-24 Cont ID  
Sent By aaponte Date 2012-04-24 Time 09:18 Rev Time 0.00
Received By aaponte Date 2012-04-24 Time 09:18 Sent To  
Notes
2012-04-24 09:18:49INTERIOR OFFICE RENOVATION.