Plan Review Details - Permit 12040290
| Plan Review Stops For Permit 12040290 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2012-04-12 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2012-04-12 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2012-04-12 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2012-04-12 11:31:38 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN (561) 805 6652 | | | E-MAIL: [email protected] | | | | | | REVIEW OF RAISED PLATFORM MANUFACTURER DETAILS. | | | | | | PROVISO: | | | STRATA TECHNICAL SHEET, PAGE 1 OF 2 STATES "DIAGONAL | | | BRACING IS REQUIRED FOR ALL STAGES HIGHER THAN 24" (61 | | | CM)." - THE PROPOSED PLATFORM HEIGHT IS 30" SO DIAGONAL | | | BRACES MUST BE INSTALLED. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2012-04-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-12 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-04-12 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2012-04-12 11:24:14 | 560 OKEECHOBEE BOULEVARD | | | PERMIT #12040290 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****PROVISO***** | | | | | | **THE PERMIT APPLICATION WAS SUBMITTED 04/11/12; | | | HOWEVER, THIS WRITER INSPECTED AND OBSERVED (04/11/12) | | | THAT THE TENTS AND PLATFORMS WERE ALREADY INSTALLED AT | | | THIS LOCATION PRIOR TO OBTAINING CITY PLAN REVIEWS AND | | | PERMITS.** | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | TENTS SHALL BE LOCATED AT LEAST 10 FEET AWAY FROM | | | BUILDING STRUCTURES. NOTE: TENTS WERE ALREADY INSTALLED | | | WITH 0 FEET BETWEEN TENT AND BUILDING STRUCTURE. | | | | | | TENT SHALL BE OF THE OPEN AREA/NO SIDEWALL TYPE, | | | OTHERWISE EMERGENCY LIGHTING AND ILLUMINATED EXIT SIGNS | | | ARE REQUIRED FOR TENTS EXCEEDING 1,200 SQUARE FEET. | | | | | | POST WEATHERPROOF NO SMOKING SIGNS IN CONSPICUOUS | | | LOCATIONS. | | | | | | PROVIDE EXIT SIGN ON BOTH EXTERIOR METAL GATES. | | | | | | PROVIDE HANDRAILS ON BOTH SIDES OF STEPS USED FOR | | | ACCESS TO THE 30" TALL PLATFORM. | | | | | | SUBMIT INFORMATION (HEIGHT, WEIGHT LOADS, | | | ACCESSIBILITY) TO BUILDING DEPT FOR REVIEW. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-12 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2012-04-12 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2012-04-11 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2012-04-11 13:35:46 | EXPEDITED | | | ON WESLEY'S DESK |
|
|
|