| Plan Review Stops For Permit 12040280 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2013-01-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-01-04 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-01-04 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2013-01-04 10:16:46 | RESIDENTIAL (R3) ADDITION FOURTH BUILDING REVIEW | | | CHECKLIST. | | | CODE: 2010 FBC. | | | | | | 1- SOIL IN THIS AREA IS QUESTIONABLE. PROVIDE SOIL TEST | | | REPORT AS REQUIRED BY SEC. R401.4 OF 2010 | | | FBC-RESIDENTIAL. (REPEAT COMMENT. OWNER SAID HE WILL | | | HAVE THE TEST DONE ON JANUARY). | | | | | | 2- ENGINEER REMOVED NOTE REGARDING THE SOIL BEARING | | | CAPACITY USED FOR THE DESIGN. ENGINEER TO SPECIFY SOIL | | | BEARING CAPACITY FOR WHICH STRUCTURE WAS DESIGNED FOR. | | | ENGINEER TO READ SOIL TEST REPORT TO VERIFY IF PROPOSED | | | FOOTING DESIGN IS ADEQUATE BASED ON THE TYPE AND | | | BEARING CAPACITY OF THE SOIL. SEC. R301.1 OF 2010 FBC. | | | (REPEAT COMMENT. NOT ADDRESSED). | | | | | | 3- REVISE INFORMATION SUBMITTED FOR ACCORDION SHUTTERS | | | INSTALLATION. ON SHEET 7 OF 7 OWNER SPECIFIED USING | | | 1/4" TAPCONS AT 6"O.C. WITH CONNECTION TYPE C1. CLEARLY | | | SPECIFY SHUTTERS MOUNTING TYPE. WALL TRACK MOUNTING ON | | | SHEET 4 OF 7 SPECIFIES CONNECTION TYPE C3. AND, THIS | | | CONNECTION TYPE IS NOT ALLOWED. SPECIFY WHICH MOUNTING | | | CONDITION USING CONNECTION TYPE C1 IS GOING TO BE USED. | | | SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | 4- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY BUILDING (2300 N. JOG RD.) TO VERIFY IF IMPACT | | | FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY IMPACT | | | FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2012-11-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-11-13 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-11-13 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2012-11-13 14:33:58 | RESIDENTIAL (R3) ADDITION THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: 2010 FBC. | | | | | | 1- SOIL IN THIS AREA IS QUESTIONABLE. PROVIDE SOIL TEST | | | REPORT AS REQUIRED BY SEC. R401.4 OF 2010 | | | FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED). | | | | | | 2- ENGINEER REMOVED NOTE REGARDING THE SOIL BEARING | | | CAPACITY USED FOR THE DESIGN. ENGINEER TO SPECIFY SOIL | | | BEARING CAPACITY FOR WHICH STRUCTURE WAS DESIGNED. | | | ENGINEER TO READ SOIL TEST REPORT TO VERIFY IF PROPOSED | | | FOOTING DESIGN IS ADEQUATE BASED ON THE TYPE AND | | | BEARING CAPACITY OF THE SOIL. SEC. R301.1 OF 2010 FBC. | | | (REPEAT COMMENT. NOT ADDRESSED). | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ACCORDION SHUTTERS. NOA 07-0828.12 SUBMITTED EXPIRED | | | ON 10/29/12. NEED CURRENT NOA. | | | | | | B) THERE ARE DIFFERENT PRODUCT APPROVALS SUBMITTED FOR | | | THE EXTERIOR DOORS. CLARIFY WHICH ONE IS GOING TO BE | | | USED. CHECK THE DESIGN PRESSURES WITH DESIGN PRESSURES | | | SPECIFIED BY THE ENGINEER. | | | | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. | | | (REPEAT COMMENT. NOT ADDRESSED). | | | | | | 5- PROVIDE COMPLETE INSTALLATION FOR THE INSTALLATION | | | OF ACCORDION SHUTTERS SUBMITTED. SEC. 107.2.1 CITY | | | AMENDMENTS TO FBC. | | | | | | 6- PROVIDE DETAILS/SPECIFICATIONS FOR DOOR STRUCTURAL | | | BUCK SIZE AS REQUIRED BY THE DOOR PRODUCT APPROVAL | | | SUBMITTED. SPECIFY ALL FASTENERS (SIZE AND SPACING). | | | STRUCTURAL BUCK TO COMPLY WITH SEC. R612.10.2.1 OF 2010 | | | FBC-RESIDENTIAL. (REPEAT COMMENT. BUCK SIZE SPECIFIED | | | DON'T COMPLY WITH PRODUCT APPROVAL SUBMITTED. AND, | | | FASTENER SPACING WAS NOT SPECIFIED. | | | | | | 7- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY BUILDING (2300 N. JOG RD.) TO VERIFY IF IMPACT | | | FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY IMPACT | | | FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | | (REPEAT COMMENT). | | | | | | | | | ****NOTE: ONE SET OF PLANS WAS TAKEN OUT AND WAS NOT | | | RETURNED. MISSING THE A/C, ELECTRICAL AND PLUMBING | | | PLANS. WE HAVE ONLY ONE COPY. NEED TO COPIES. | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-08-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-08-07 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-08-07 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2012-08-07 15:21:25 | RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- SOIL IN THIS AREA IS QUESTIONABLE. PROVIDE SOIL TEST | | | REPORT AS REQUIRED BY SEC. R401.4 OF 2010 | | | FBC-RESIDENTIAL. | | | NOTE: ENGINEER REMOVED NOTE REGARDING THE SOIL BEARING | | | CAPACITY USED FOR THE DESIGN. ENGINEER TO SPECIFY SOIL | | | BEARING CAPACITY FOR WHICH STRUCTURE WAS DESIGNED. | | | ENGINEER TO READ SOIL TEST REPORT TO VERIFY IF PROPOSED | | | FOOTING DESIGN IS ADEQUATE BASED ON THE TYPE AND | | | BEARING CAPACITY OF THE SOIL. | | | | | | 2- REVISE THE ENERGY CALCULATIONS TO MATCH PLANS. | | | A) PLANS SHOW VENTED ATTIC. | | | B) ROOF MATERIAL IS SHINGLES NOT CONCRETE TILE. | | | C) CEILING TYPE IS NOT CATHEDRAL/SINGLE ASSEMBLY. SEE | | | PLANS AND REVISE. | | | D) KITCHEN IS NOT INCLUDED IN THE ADDITION. SEE PLANS. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) SINGLE HUNG WINDOWS. NOA 06-0407.02 SUBMITTED | | | EXPIRED ON AUGUST 10, 2011. PROVIDE TWO NEW COPIES. | | | | | | B) SHUTTERS IF NOT USING IMPACT WINDOWS. AND, PROVIDE | | | COMPLETE INSTALLATION SCHEDULE. PROVIDE 2 COPIES. | | | | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. SEC. 109.3 CITY AMENDMENTS. VALUATION WAS UPDATED, | | | OWES $1432.91. | | | | | | 6- PROVIDE DETAILS/SPECIFICATIONS FOR DOOR STRUCTURAL | | | BUCK SIZE AS REQUIRED BY THE DOOR PRODUCT APPROVAL | | | SUBMITTED. SPECIFY ALL FASTENERS. STRUCTURAL BUCK TO | | | COMPLY WITH SEC. R612.10.2.1 OF 2010 FBC-RESIDENTIAL. | | | | | | 7- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY BUILDING (2300 N. JOG RD.) TO VERIFY IF IMPACT | | | FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY IMPACT | | | FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-05-15 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-05-14 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2012-05-15 10:06:58 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | | | | 1- AFTER PLANS ARE REVISED, PLEASE BRING THEM TO PALM | | | BEACH COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES | | | ARE DUE. THEN, BRING BACK STAMPED PLANS AND COPY OF | | | PAID RECEIPT IF FEES ARE DUE. | | | | | | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | | BY SEC. 401 OF 2010 FBC-ENERGY CONSERVATION. | | | | | | 3- ENGINEER NEEDS TO UPDATE ALL THE PLANS. CURRENT CODE | | | IN EFFECT IS THE 2010 FLORIDA RESIDENTIAL CODE AND THE | | | 2010 FBC. REVISE ALL THE DESIGN INFORMATION | | | ACCORDINGLY. UPDATE IN ALL PLANS ALL THE INFORMATION | | | THAT REFERENCES THE 2007 FBC AND THE ASCE 7-05 AND | | | REFERENCE CORRECT CURRENT SECTION. | | | | | | 4- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) SINGLE HUNG WINDOWS SPECIFIED ON PLANS. NOA | | | 09-0316.10 SUBMITTED WAS SUPERSEDED BY MIAMI-DADE. | | | PLEASE VISIT THE MIAMI-DADE WEBSITE AND DOWNLOAD | | | CURRENT NOA. | | | | | | B) ROOF SHINGLES. PROVIDE 2 COPIES. ONLY ONE WAS | | | SUBMITTED. | | | | | | C) EXTERIOR DOOR. PROVIDE 2 COPIES. ONLY ONE WAS | | | SUBMITTED. | | | | | | D) HURRICANE SHUTTERS FOR SINGLE HUNG WINDOWS SINCE | | | WINDOWS HAVE NO IMPACT GLASS. AND, PROVIDE COMPLETE | | | INSTALLATION SCHEDULE SHOWING SPECIFIC MOUNTING | | | CONDITIONS AND ANCHOR TYPE AND SPACING TO BE USED. | | | | | | E) ALL USP STRUCTURAL CONNECTORS SPECIFIED BY THE | | | ENGINEER ON PLANS AND DETAILS. PROVIDE ONLY THE PRODUCT | | | APPROVAL COVER PAGE AND PAGE SHOWING THE STRUCTURAL | | | CONNECTOR ONLY. THIS APPLIES TO STRUCTURAL CONNECTORS | | | ONLY. | | | | | | 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC. | | | | | | 6- ENGINEER SPECIFIED ON WALL SECTION ON SHEET A-1 AND | | | ON SHEET A-3 THAT THE SOIL WAS OBSERVED TO BE SAND AND | | | ROCK. THIS IS NOT THE TYPE OF SOIL ON THIS AREA. | | | PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. R401.4 AND | | | ENGINEER TO REVISE SPECS AS REQUIRED BASED ON THE SOIL | | | TEST REPORT FINDINGS. | | | | | | 7- WALL SECTIONS SPECIFY ROOF PITCH OF 3/12. ENGINEER | | | NEEDS TO SPECIFY 2 LAYERS OF UNDERLAYMENT AS REQUIRED | | | BY SEC. R905.2.2. | | | | | | 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS AND | | | DESIGN PROFESSIONAL FEES. SEC. 109.3 OF CITY AMENDMENTS | | | TO FBC. VALUATION WAS UPDATED. OWES $1432.91. | | | | | | 9- WALL SECTION ON SHEET A-3 SHOWS THAT EXISTING | | | TRUSSES ARE TO BE CUT TO RECEIVE NEW WALL. ENGINEER TO | | | PROVIDE SPECIFICATIONS SHOWING HOW THE EXISTING TRUSSES | | | ARE TO BE REINFORCED SO THE STRUCTURAL STABILITY IS NOT | | | AFFECTED. SEC. 107.2.1.3 CITY AMENDMENTS TO FBC. | | | | | | 10- PROVIDE DETAILS/SPECIFICATIONS FOR DOORS AND | | | WINDOWS BUCKS AS REQUIRED BY SEC. R612.10.2.1. | | | | | | 11-WALL SECTION ON SHEET A-1: | | | A) FOOTING NEEDS TO BE MIN. 12" BELOW GRADE. SEC. | | | R403.1.4. REVISE AS REQUIRED. | | | | | | B) SPECIFY ROOF EDGE WIDTH. 4'-0" WIDE MIN. AS REQUIRED | | | BY FIGURE R301.2(7). | | | | | | 12- DOOR SCHEDULE ON SHEET A-1 IS MISSING DOOR #3 FOR | | | NEW BEDROOM. REVISE AS REQUIRED. | | | | | | 13- SHEET A-2: | | | A) FOUNDATION PLAN IS MISSING THE SPECIFICATION FOR THE | | | WATER VAPOR BARRIER AS REQUIRED BY SEC. R506.2.3. | | | | | | B) ROOFING LOADS. SPECIFY ALL THE LIVE, DEAD AND WIND | | | LOADS AS REQUIRED BY SEC. R301.1, TABLE R301.2(2) AND | | | TABLE R301.5. AND CLEARLY IDENTIFY ALL ROOF ZONES AND | | | WALL ZONES. | | | | | | C) UPDATE THE WIND CODE EDITION AND THE SECTIONS | | | REFERENCED ON ON THE FOOTING AND TIE BEAM DETAIL. | | | CURRENT CODE IW THE 2010 FLORIDA RESIDENTIAL CODE AND | | | 2010 FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-04-30 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-04-30 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-04-30 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2013-02-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-02-14 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-02-14 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2013-02-14 14:04:50 | TALKED TO MR. HARRIS. HE SAID HE CAN'T GET THE | | | GEOTECHNICAL ENGINEER TO DO THE SOIL TEST REPORT. HE | | | SAID THEY DIDN'T SHOW UP. I TOLD HIM THIS AREA IS KNOWN | | | TO HAVE MUCK AND THE SOIL TEST REPORT IS REQUIRED TO | | | PROPERLY DESIGN THE FOUNDATION AND PROPERLY PREPARE THE | | | SOIL TO RESIST THE NEW BUILDING LOADS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-01-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-01-04 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-12-27 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2013-01-04 09:49:56 | MET WITH MR. HARRIS. PRODUCT APPROVALS AND REVISED | | | DRAWINGS SUBMITTED. HE SAID SOIL TEST REPORT WILL BE | | | DONE IN JANUARY. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-11-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-11-13 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-11-06 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2012-11-07 09:11:16 | SENT TO ZONING SHELF FOR JOHN'S REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-08-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-08-08 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-07-03 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-05-15 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-04-11 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2013-01-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-01-04 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-01-04 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2013-01-04 10:00:31 | NEED PALM BEACH COUNTY IMPACT FEES STAMP ON PLANS AND | | | COPY OF PAID RECEIPT IF FEES ARE DUE AS REQUIRED BY THE | | | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | | DEVELOPMENT CODE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2012-11-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-11-13 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-11-13 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2012-11-13 16:50:47 | NEED PALM BEACH COUNTY IMPACT FEES STAMP ON PLANS AND | | | COPY OF PAID RECEIPT IF FEES ARE DUE AS REQUIRED BY THE | | | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | | DEVELOPMENT CODE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2012-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-08-07 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-08-07 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2012-08-07 14:50:25 | NEED PALM BEACH COUNTY IMPACT FEES STAMP ON PLANS AND | | | COPY OF PAID RECEIPT IF FEES ARE DUE AS REQUIRED BY THE | | | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | | DEVELOPMENT CODE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-05-15 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-05-15 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2012-05-15 08:48:37 | AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY TO CHECK IF IMPACT FEES ARE DUE. BRING BACK | | | STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-08-07 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-08-07 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-08-07 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-05-15 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-05-15 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2012-05-15 14:22:10 | RESIDENTIAL (R3) ADDITION MECHANICAL REVIEW COMMENTS. | | | 2010 FLORIDA RESIDENTIAL CODE & 2010 FBC. | | | | | | 1- PROVIDE EQUIPMENT SIZING CALCULATIONS (2 COPIES) AS | | | REQUIRED BY SEC. 403.6 OF 2010 FBC- ENERGY | | | CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2012-11-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-11-13 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-11-13 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2012-08-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-08-08 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-08-08 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2012-08-08 13:15:59 | RESIDENTIAL (R3) ADDITION SECOND PLUMBING REVIEW | | | COMMENTS. | | | 2010 FLORIDA RESIDENTIAL CODE. | | | | | | 1- PROVIDE PLUMBING RISER DIAGRAM AS REQUIRED BY SEC. | | | 107.3.5.3(11) OF CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-05-15 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-05-15 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2012-05-15 14:31:36 | RESIDENTIAL (R3) ADDITION PLUMBING REVIEW COMMENTS. | | | 2010 FLORIDA RESIDENTIAL CODE. | | | | | | 1- PROVIDE PLUMBING RISER DIAGRAM AS REQUIRED BY SEC. | | | 107.3.5.3(11) OF CITY AMENDMENTS TO FBC. | | | | | | 2- SPECIFY LOCATION OF WATER HEATER TO VERIFY | | | COMPLIANCE WITH SEC. M2005. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2013-01-03 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-01-03 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-01-03 |
Time |
09:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2012-11-07 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-11-07 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-11-07 |
Time |
|
Sent To |
B |
|
| Notes |
| 2012-11-07 16:25:02 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 11.07.2012 | | | PERMIT NO.: 12040280 | | | ADDRESS: 1371 9TH COURT | | | CONTRACTOR/CONTACT: LAWRENCE HARRIS | | | TELEPHONE NO.: 561.213.2668 | | | SCOPE OF REVIEW: ADDITION OF 2 BEDROOMS AND 1 BATH TO | | | EXISTING RESIDENCE. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. REPEAT COMMENT: PLEASE NOTE THE HEIGHT OF THE | | | PROPOSED ADDITION. BUILDING HEIGHT SHALL BE MEASURED | | | FROM GRADE TO THE MEAN POINT OF THE PITCHED ROOF. | | | | | | 2. IT APPEARS THAT THE VALUE OF WORK WAS INCREASED FROM | | | $20,000 TO $51,520. PURSUANT TO SECTION 94-441 OF THE | | | CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS), | | | ANY WORK PROPOSED TO EXCEED 50% OF THE VALUE OF THE | | | STRUCTURE SHALL REQUIRE THAT THE PROPERTY BE BROUGHT | | | INTO COMPLIANCE WITH ARTICLE XIV (LANDSCAPING) OF THE | | | ZLDRS. PLEASE PROVIDE A LANDSCAPE INDICATING COMPLIANCE | | | WITH THE FOLLOWING: | | | | | | A. 1 SHADE/FLOWERING/FRUIT TREE SHALL BE PLANTED FOR | | | EACH 1,200 SQUARE FEET OF OPEN SPACE. | | | | | | B. 1 SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE FEET OF | | | OPEN SPACE. | | | | | | IF THE EXISTING LANDSCAPING CONFORMS TO THESE | | | PROVISIONS, THEN ONLY A PLAN SHOWING THE EXISTING | | | PLANTING, ALONG WITH A DATA TABLE INDICATING COMPLIANCE | | | WITH ARTICLE XIV SHALL BE PROVIDED. PLEASE NOTE THAT | | | THE DATA TABLE SHOULD NOTE THE SIZE AND SPECIES OF THE | | | EXISTING TREES/SHRUBS. IF ADDITIONAL MATERIAL NEEDS TO | | | BE INSTALLED IN ORDER TO COMPLY WITH THE PROVISIONS OF | | | ARTICLE XIV, THEN A SEPARATE LANDSCAPE PERMIT | | | APPLICATION SHALL BE SUBMITTED. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | | | 2012-11-07 11:45:21 | GAVE TO J.R. - MD |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2012-07-12 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-07-12 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-07-12 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2012-07-12 14:45:10 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.12.2012 | | | PERMIT NO.: 12040280 | | | ADDRESS: 1371 9TH COURT | | | CONTRACTOR/CONTACT: LAWRENCE HARRIS | | | TELEPHONE NO.: 561.213.2668 | | | SCOPE OF REVIEW: ADDITION OF 2 BEDROOMS AND 1 BATH TO | | | EXISTING RESIDENCE. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. REPEAT COMMENT: TWO (2) COPIES OF A CURRENT AND | | | ACCURATE SURVEY SHALL BE PROVIDED. | | | | | | 2. REPEAT COMMENT: PLEASE NOTE THE HEIGHT OF THE | | | PROPOSED ADDITION. BUILDING HEIGHT SHALL BE MEASURED | | | FROM GRADE TO THE MEAN POINT OF THE PITCHED ROOF. | | | | | | 3. IT APPEARS THAT THE VALUE OF WORK WAS INCREASED FROM | | | $20,000 TO $51,520. PURSUANT TO SECTION 94-441 OF THE | | | CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS), | | | ANY WORK PROPOSED TO EXCEED 50% OF THE VALUE OF THE | | | STRUCTURE SHALL REQUIRE THAT THE PROPERTY BE BROUGHT | | | INTO COMPLIANCE WITH ARTICLE XIV (LANDSCAPING) OF THE | | | ZLDRS. PLEASE PROVIDE A LANDSCAPE INDICATING COMPLIANCE | | | WITH THE FOLLOWING: | | | | | | A. 1 SHADE/FLOWERING/FRUIT TREE SHALL BE PLANTED FOR | | | EACH 1,200 SQUARE FEET OF OPEN SPACE. | | | | | | B. 1 SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE FEET OF | | | OPEN SPACE. | | | | | | IF THE EXISTING LANDSCAPING CONFORMS TO THESE | | | PROVISIONS, THEN ONLY A PLAN SHOWING THE EXISTING | | | PLANTING, ALONG WITH A DATA TABLE INDICATING COMPLIANCE | | | WITH ARTICLE XIV SHALL BE PROVIDED. PLEASE NOTE THAT | | | THE DATA TABLE SHOULD NOTE THE SIZE AND SPECIES OF THE | | | EXISTING TREES/SHRUBS. IF ADDITIONAL MATERIAL NEEDS TO | | | BE INSTALLED IN ORDER TO COMPLY WITH THE PROVISIONS OF | | | ARTICLE XIV, THEN A SEPARATE LANDSCAPE PERMIT | | | APPLICATION SHALL BE SUBMITTED. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2012-04-25 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-04-25 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-04-25 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2012-04-25 10:30:14 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 04.25.2012 | | | PERMIT NO.: 12040280 | | | ADDRESS: 1371 9TH COURT | | | CONTRACTOR/CONTACT: LAWRENCE HARRIS | | | TELEPHONE NO.: 561.213.2668 | | | SCOPE OF REVIEW: ADDITION OF 2 BEDROOMS AND 1 BATH TO | | | EXISTING RESIDENCE. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. | | | 2. PLEASE NOTE THE HEIGHT OF THE PROPOSED ADDITION. | | | BUILDING HEIGHT SHALL BE MEASURED FROM GRADE TO THE | | | MEAN POINT OF THE PITCHED ROOF. | | | 3. PLANS INDICATE THE ADDITION OF A CONDENSING UNIT AT | | | THE REAR OF THE PROPOSED ADDITION. PLEASE NOTE THE | | | SETBACKS FROM THE CONDENSING UNIT TO ALL ADJACENT | | | PROPERTY LINES (SIDES AND REAR). MECHANICAL EQUIPMENT | | | SHALL NOT ENCROACH MORE THAN FOUR (4) FEET INTO ANY | | | REQUIRED SETBACK. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|