Plan Review Details - Permit 12040273
| Plan Review Stops For Permit 12040273 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2012-04-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-23 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-20 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-04-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-23 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-23 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2012-04-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-23 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-23 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2012-04-23 07:44:45 | NO GAS SHOWN ON PLANS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-27 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-26 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2012-04-26 12:36:05 | SENT TO R MCDOUGALS DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-24 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-11 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2012-04-11 14:10:57 | IN ZONING BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-27 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-27 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2012-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-24 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-24 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2012-04-24 10:51:13 | 2010 FBC | | | | | | DENIED BY PLUMBING | | | | | | 1) SUBMIT TWO COPIES OF THE PUMP CURVE FOR THE PENTAIR | | | VS-3050 POOL PUMP AND TOTAL DYNAMIC HEAD CALCULATIONS | | | SHOWING HOW THE MAXIMUM FLOW RATE OF 120 GPM WAS | | | DETERMINED. THE PUMP CURVES THAT I WAS ABLE TO VIEW ON | | | LINE HAD CUSTOMIZABLE MAXIMUM FLOW RATES OF OVER 140 | | | GPM AND THE FACTORY SET MAXIMUM FLOW RATES WERE CLOSE | | | TO 130 GPM. THE MAXIMUM VELOCITY OF 8 FT PER SECOND | | | ALLOWED BY ANSI/SPA 4.4 IS EXCEEDED AT THESE MAXIMUM | | | FLOW RATES IN 2 & 1/2 " PIPE. FBC 4101.6.3 | | | | | | 2) THE VALUE FOR POOL SPECIFIED ON THE APPLICATION | | | APPEARS TO BE LOW. BASED ON MARSHALL AND SWIFT THE | | | VALUE FOR THIS POOL SHOULD BE BETWEEN $14,000 AND | | | $15,000. FOR PERMITTING COST THE TOTAL VALUE OF THE | | | WORK IS REQUIRED, INCLUDING LABOR, MATERIALS, DESIGN | | | FEES, OVERHEAD AND PROFIT (REPLACEMENT VALUE). PLEASE | | | ADJUST THE VALUE ACCORDINGLY. CITY AMENDMENTS 108.3 | | | | | | 3) PLEASE RESPOND TO THE REVIEW COMMENTS IN WRITING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2012-04-20 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2012-04-20 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2012-04-13 |
Time |
08:36 |
Sent To |
P |
|
| Notes |
| 2012-04-13 08:36:27 | GIVEN TO LF |
|
|
|
Account Summary | Usage Policy | Privacy Policy