Plan Review Details - Permit 12040273
Plan Review Stops For Permit 12040273
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-04-23 Cont ID  
Sent By rmcdouga Date 2012-04-23 Time 07:55 Rev Time 0.00
Received By rmcdouga Date 2012-04-20 Time 16:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-04-23 Cont ID  
Sent By rmcdouga Date 2012-04-23 Time 07:44 Rev Time 0.00
Received By rmcdouga Date 2012-04-23 Time 07:44 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2012-04-23 Cont ID  
Sent By rmcdouga Date 2012-04-23 Time 07:40 Rev Time 0.00
Received By rmcdouga Date 2012-04-23 Time 07:40 Sent To  
Notes
2012-04-23 07:44:45NO GAS SHOWN ON PLANS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-04-27 Cont ID  
Sent By rmcdouga Date 2012-04-27 Time 13:45 Rev Time 0.00
Received By rmcdouga Date 2012-04-26 Time 12:35 Sent To  
Notes
2012-04-26 12:36:05SENT TO R MCDOUGALS DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-04-24 Cont ID  
Sent By rmcdouga Date 2012-04-24 Time 10:35 Rev Time 0.00
Received By rmcdouga Date 2012-04-11 Time 14:10 Sent To  
Notes
2012-04-11 14:10:57IN ZONING BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-04-27 Cont ID  
Sent By rmcdouga Date 2012-04-27 Time 13:45 Rev Time 0.00
Received By rmcdouga Date 2012-04-27 Time 13:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-04-24 Cont ID  
Sent By rmcdouga Date 2012-04-24 Time 10:35 Rev Time 0.00
Received By rmcdouga Date 2012-04-24 Time 10:35 Sent To  
Notes
2012-04-24 10:51:132010 FBC
  
 DENIED BY PLUMBING
  
 1) SUBMIT TWO COPIES OF THE PUMP CURVE FOR THE PENTAIR
 VS-3050 POOL PUMP AND TOTAL DYNAMIC HEAD CALCULATIONS
 SHOWING HOW THE MAXIMUM FLOW RATE OF 120 GPM WAS
 DETERMINED. THE PUMP CURVES THAT I WAS ABLE TO VIEW ON
 LINE HAD CUSTOMIZABLE MAXIMUM FLOW RATES OF OVER 140
 GPM AND THE FACTORY SET MAXIMUM FLOW RATES WERE CLOSE
 TO 130 GPM. THE MAXIMUM VELOCITY OF 8 FT PER SECOND
 ALLOWED BY ANSI/SPA 4.4 IS EXCEEDED AT THESE MAXIMUM
 FLOW RATES IN 2 & 1/2 " PIPE. FBC 4101.6.3
  
 2) THE VALUE FOR POOL SPECIFIED ON THE APPLICATION
 APPEARS TO BE LOW. BASED ON MARSHALL AND SWIFT THE
 VALUE FOR THIS POOL SHOULD BE BETWEEN $14,000 AND
 $15,000. FOR PERMITTING COST THE TOTAL VALUE OF THE
 WORK IS REQUIRED, INCLUDING LABOR, MATERIALS, DESIGN
 FEES, OVERHEAD AND PROFIT (REPLACEMENT VALUE). PLEASE
 ADJUST THE VALUE ACCORDINGLY. CITY AMENDMENTS 108.3
  
 3) PLEASE RESPOND TO THE REVIEW COMMENTS IN WRITING.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2012-04-20 Cont ID  
Sent By ajones Date 2012-04-20 Time 14:42 Rev Time 0.00
Received By ajones Date 2012-04-13 Time 08:36 Sent To P
Notes
2012-04-13 08:36:27GIVEN TO LF


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved