| Plan Review Stops For Permit 12040097 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-06-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-06-01 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-06-01 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2012-04-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-04-18 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-04-18 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2012-04-18 16:38:59 | BUILDING PLAN REVIEW | | | PERMIT: 12040097 | | | ADD: 2481 OKEECHOBEE BLVD | | | CONT: TO BE DETERMINED | | | TEL: (407)661-9100 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1A) SHEET A-700 :PRODUCT APPROVAL | | | STANLEY ACCESS TECHNOLOGIES | | | NOA 09-0312.17 | | | DURA-GLIDE "3000" ALUMINUM AUTOMATIC SLIDDING GLASS | | | DOOR, W BREAKOUT DOORS | | | NON-IMPACT GLAZING, WILL REQUIRE EITHER IMPACT RATED | | | GLAZING OR SHUTTERS WILL BE REQUIRED FOR THESE | | | OPENINGS. | | | | | | 1B) SHEET A-700 STANLEY DUR-GLIDE NOA IS MISSING SHEET | | | THREE OF THE NOA. | | | | | | 2) SHEET A-704 / A-707 PRODUCT APPROVAL | | | JOHN MANVILLE ROOFING | | | NOA 09-1013.05 | | | JM TPO SINGLE PLY ROOFING OVER STEEL DECK | | | THE SUB-SYSTEMS ARE NOT CIRCLED INDICATING WHICH SYSTEM | | | WILL BE INSTALLED, EACH SUB-SYSTEM HAS ITS OWN | | | PRESSURES, SEE THE LAST PAGE OF THE NOA LIMITATION #7 | | | AND 9. | | | ENHANCED FASTENING IS ALLOWED WITH LIMITATION NUMBER 7. | | | | | | 3) SHEET A-121: | | | 3A) PLANS INDICATE THE USE OF A NEW ROOF HATCH RULE | | | 9N-3 (31)(A) ROOF ACCESS HATCHES REQUIRE PRODUCT | | | APPROVALS/ 1609.COMPONENTS & CLADDING. | | | | | | 3B) DETAIL A1 INDICATES THE USSE OF RAINLOC PANEL | | | SYSTEM RULE 9N-3(31)(C) SIDING, WALL PANELS REQUIRE | | | PRODUCT APPROVALS/ 1609. COMPONENTS & CLADDING. | | | | | | 4) SHEET S-001 FOUNDATION NOTE B INDICATES THERE IS TO | | | BE GEOTECHNICAL SOILS REPORT COMPLETED ANDSUBMITTED | | | DESCRIBING THE INVESTIGATION AND ANY NON-CONFORMITIES. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-05-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-17 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-16 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-05-07 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-07 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-04 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2012-05-07 09:17:51 | 12040097 | | | 2471 OKEECHOBEE BLVD. | | | ALDI FOOD STORE | | | | | | 1. VERIFY THE ELECTRICAL SERVICE MAINS FOR THIS | | | BUILDING ARE SIX OR LESS AND GROUPED IN ONE LOCATION. | | | THE SITE PLANS SUGGEST THIS BUILDING MAY ALREADY BE | | | SERVED FROM ANOTHER LOCATION. NEC 230.2, 230.71, 230.72 | | | 2. PROVIDE AN INTERSYSTEM BONDING POINT. NEC 250.94 | | | 3. PROVIDE A LIGHTING DENSITY CALCULATION VERIFYING | | | COMPLIANCE WITH THE 2010 FLORIDA BUILDING ENERGY CODE | | | REQUIREMENTS. FBC EC 505.5.3 | | | 4. PROVIDE A DETAIL WHICH PROVIDES A DEDICATED WORKING | | | SPACE FOR THE ELECTRICAL EQUIPMENT AND PANEL BOARDS. | | | NEC 110.26, 240.24, 408.17 | | | 5. A GFCI GENERAL PURPOSE RECEPTACLE IS REQUIRED AT AN | | | ACCESSIBLE LOCATION FOR THE SERVICE OF HEATING, AIR | | | CONDITIONING, AND REFRIGERATION EQUIPMENT LOCATED ON | | | THE ROOF. NEC 210.63 | | | 6. PROVIDE THE SPECIFICATIONS AND LISTINGS FOR THE | | | GENERATOR QUICK CONNECT. NEC 90.7 | | | 7. VERIFY LISTING BY A NATIONALLY RECOGNIZED TESTING | | | LABORATORY (NRTL) FOR THE FACTORY WIRED ?POWER WALL? | | | ASSEMBLIES NOTED ON THE PLANS AS PANEL BOARD L1AND L2. | | | NEC 90.7, 215.5 | | | 8. VERIFY LISTING BY A NATIONALLY RECOGNIZED TESTING | | | LABORATORY OF THE FACTORY WIRED ?PROTOCOL RACK? | | | ASSEMBLY NOTED ON THE PLANS FOR REFRIGERATION. NEC 90.7 | | | 9. VERIFY LISTING BY A NATIONALLY RECOGNIZED TESTING | | | LABORATORY OF THE OWNER SUPPLIED UPS. NEC 90.7 | | | 10. PROVIDE A SAFETY LABELING SCHEDULE FOR THE | | | ELECTRICAL EQUIPMENT WHICH INCLUDES SPECIFIC WORDING | | | REGARDING THE SIZE AND TYPE OF HAZARDS. NEC 110.22, | | | 110.16 | | | | | | NOTE: | | | SEPARATE PERMITS AND PLANS ARE REQUIRED FOR THE FIRE | | | ALARM SYSTEM, SECURITY, VOICE AND DATA. | | | | | | ROBERT LECKY, CBO | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2012-05-03 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2012-05-03 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2012-05-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2012-05-03 14:33:01 | PROVISOS: | | | | | | #1 SUBMITTAL DOES NOT INCLUDE EXTERIOR WORK THAT WILL | | | BE REVIEWED BY PLANNING AND ZONING. | | | | | | #2 PERMIT ONLY EXTERIOR ELEMENTS EXCLUDING UTILITY | | | ELEMENTS THAT WILL BE REVIEWED BY ENGINEERING SERVICES | | | UNDER PERMIT # E12040007 | | | | | | #3 EXCLUDE UTILITY ELEMENTS FROM THE VALUATION AT DSD. | | | | | | PLEASE CONTACT ME IF ANY QUESTIONS. THANK YOU! | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2012-06-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-06-05 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-06-05 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2012-06-05 10:51:36 | 2481 OKEECHOBEE BOULEVARD | | | PERMIT #12040097 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. SMOKING | | | SHALL BE PROHIBITED EXCEPT IN DESIGNATED EXTERIOR | | | AREAS. ALL OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL | | | HAVE "NO SMOKING" SIGNS POSTED. | | | | | | WHERE SMOKING IS PERMITTED, SAFE RECEPTACLES FOR | | | SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF | | | THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | A KNOX-BOX KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | EXIT DOORS EQUIPPED WITH DELAYED EGRESS LOCKING SYSTEMS | | | SHALL COMPLY WITH THE FOLLOWING: | | | 1) UNLOCK UPON ACTUATION OF THE FIRE SPRINKLER OR FIRE | | | ALARM SYSTEM | | | 2) UNLOCK UPON LOSS OF POWER CONTROLLING THE LOCKING | | | MECHANISM | | | 3) AN IRREVERSIBLE PROCESS SHALL RELEASE THE LOCK | | | WITHIN 15 SECONDS, UPON APPLICATION OF A FORCE TO THE | | | RELEASE DEVICE REQUIRED IN 7.2.1.5.9 UNDER THE | | | FOLLOWING CONDITIONS: | | | (A) THE FORCE SHALL NOT BE REQUIRED TO EXCEED 15 LBF | | | (67 N). | | | (B) THE FORCE SHALL NOT BE REQUIRED TO BE CONTINUOUSLY | | | APPLIED FOR MORE THAN 3 SECONDS. | | | (C) THE INITIATION OF THE RELEASE PROCESS SHALL | | | ACTIVATE AN AUDIBLE SIGNAL IN THE VICINITY OF THE DOOR | | | OPENING. | | | (D) ONCE THE LOCK HAS BEEN RELEASED BY THE APPLICATION | | | OF FORCE TO THE RELEASING DEVICE, RELOCKING SHALL BE BY | | | MANUAL MEANS ONLY. | | | (4)A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. HIGH AND NOT LESS THAN 1/8 IN. IN STROKE | | | WIDTH ON A CONTRASTING BACKGROUND THAT READS AS FOLLOWS | | | SHALL BE LOCATED ON THE DOOR LEAF ADJACENT TO THE | | | RELEASE DEVICE: "PUSH UNTILALARM SOUNDS DOOR CAN BE | | | OPENED IN 15 SECONDS" | | | | | | EXIT DOORS EQUIPPED WITH POWERED DOOR LEAF OPERATION | | | SHALL COMPLY WITH THE FOLLOWING: | | | 1) IN THE EVENT OF POWER FAILURE, THE LEAVES OPEN | | | MANUALLY TO ALLOW EGRESS TRAVEL OR CLOSE WHEN NECESSARY | | | TO SAFEGUARD THE MEANS OF EGRESS. | | | 2) THE FORCE REQUIRED TO SET THE LEAF IN MOTION SHALL | | | NOT EXCEED 50 LBF (222 N). | | | 3) THE DOOR ASSEMBLY SHALL BE DESIGNED AND INSTALLED SO | | | THAT, WHEN A FORCE IS APPLIED TO THE DOOR LEAF ON THE | | | SIDE FROM WHICH EGRESS IS MADE, IT SHALL BE CAPABLE OF | | | SWINGING FROM ANY POSITION TO PROVIDE FULL USE OF THE | | | REQUIRED WIDTH OF THE OPENING IN WHICH IT IS INSTALLED. | | | 4) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. HIGH ON A CONTRASTING BACKGROUND THAT READS | | | AS FOLLOWS SHALL BE LOCATED ON THE EGRESS SIDE OF EACH | | | DOOR OPENING: "IN EMERGENCY - PUSH TO OPEN" | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2012-04-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-17 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-04-17 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2012-04-17 14:37:53 | 2471 OKEECHOBEE BOULEVARD | | | PERMIT #12040097 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. SMOKING | | | SHALL BE PROHIBITED EXCEPT IN DESIGNATED EXTERIOR | | | AREAS. ALL OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL | | | HAVE "NO SMOKING" SIGNS POSTED. | | | | | | WHERE SMOKING IS PERMITTED, SAFE RECEPTACLES FOR | | | SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF | | | THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | A KNOX-BOX KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | EXIT DOORS EQUIPPED WITH DELAYED EGRESS LOCKING SYSTEMS | | | SHALL COMPLY WITH THE FOLLOWING: | | | 1) UNLOCK UPON ACTUATION OF THE FIRE SPRINKLER OR FIRE | | | ALARM SYSTEM | | | 2) UNLOCK UPON LOSS OF POWER CONTROLLING THE LOCKING | | | MECHANISM | | | 3) AN IRREVERSIBLE PROCESS SHALL RELEASE THE LOCK | | | WITHIN 15 SECONDS, UPON APPLICATION OF A FORCE TO THE | | | RELEASE DEVICE REQUIRED IN 7.2.1.5.9 UNDER THE | | | FOLLOWING CONDITIONS: | | | (A) THE FORCE SHALL NOT BE REQUIRED TO EXCEED 15 LBF | | | (67 N). | | | (B) THE FORCE SHALL NOT BE REQUIRED TO BE CONTINUOUSLY | | | APPLIED FOR MORE THAN 3 SECONDS. | | | (C) THE INITIATION OF THE RELEASE PROCESS SHALL | | | ACTIVATE AN AUDIBLE SIGNAL IN THE VICINITY OF THE DOOR | | | OPENING. | | | (D) ONCE THE LOCK HAS BEEN RELEASED BY THE APPLICATION | | | OF FORCE TO THE RELEASING DEVICE, RELOCKING SHALL BE BY | | | MANUAL MEANS ONLY. | | | (4)A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. HIGH AND NOT LESS THAN 1/8 IN. IN STROKE | | | WIDTH ON A CONTRASTING BACKGROUND THAT READS AS FOLLOWS | | | SHALL BE LOCATED ON THE DOOR LEAF ADJACENT TO THE | | | RELEASE DEVICE: "PUSH UNTILALARM SOUNDS DOOR CAN BE | | | OPENED IN 15 SECONDS" | | | | | | EXIT DOORS EQUIPPED WITH POWERED DOOR LEAF OPERATION | | | SHALL COMPLY WITH THE FOLLOWING: | | | 1) IN THE EVENT OF POWER FAILURE, THE LEAVES OPEN | | | MANUALLY TO ALLOW EGRESS TRAVEL OR CLOSE WHEN NECESSARY | | | TO SAFEGUARD THE MEANS OF EGRESS. | | | 2) THE FORCE REQUIRED TO SET THE LEAF IN MOTION SHALL | | | NOT EXCEED 50 LBF (222 N). | | | 3) THE DOOR ASSEMBLY SHALL BE DESIGNED AND INSTALLED SO | | | THAT, WHEN A FORCE IS APPLIED TO THE DOOR LEAF ON THE | | | SIDE FROM WHICH EGRESS IS MADE, IT SHALL BE CAPABLE OF | | | SWINGING FROM ANY POSITION TO PROVIDE FULL USE OF THE | | | REQUIRED WIDTH OF THE OPENING IN WHICH IT IS INSTALLED. | | | 4) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. HIGH ON A CONTRASTING BACKGROUND THAT READS | | | AS FOLLOWS SHALL BE LOCATED ON THE EGRESS SIDE OF EACH | | | DOOR OPENING: "IN EMERGENCY - PUSH TO OPEN" | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-06-07 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-16 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-05-07 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-07 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-04-05 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2012-04-05 10:46:13 | INCOMING SENT TO C-04. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2012-06-27 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2012-06-27 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2012-06-27 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2012-06-27 11:37:11 | PALM BEACH COUNTY PROVIDED IMPACT FEE STAMP ON PLAN | | | STATING THAT NO IMPACT FEES ARE DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2012-04-24 19:42:14 | PER COUNTY TRAFFIC ENGINEERING LETTER RENOVATIONS ADDED | | | 324 SF TO EXISTING BUILDING. NEED COUNTY IMPACT | | | APPROVAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2012-04-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-04-17 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-04-16 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2012-04-17 08:56:47 | PROVISO | | | 1) REFER TO SECTION 503.2.4.4 SHUTOFF DAMPER CONTROLS | | | 2010 FLORIDA ENERGY CODE ( OUT SIDE AIR) | | | 2) REFER TO SECTION 307.2.3.1 WATER LEVEL MONITORING | | | DEVICE. 2010 FBC (M) | | | 3) REFER TO SECTION 307.2.1 CONDENSATE DISPOSAL. 2010 | | | FBC (M) | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-04-20 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-04-20 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-04-20 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2012-04-20 14:47:58 | ***PROVISO*** | | | NO HORIZONTAL DRY VENTS PERMITTED 905.4 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2012-05-03 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2012-05-03 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2012-04-23 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2012-05-03 14:19:27 | 5/3/12 PERMIT WAS PICKED-UP FROM ENGINEERING. LMF | | 2012-05-03 14:18:55 | | | | | | | PLANNING: **** PASSED WITH PROVISO, SUBMIT SEPARATE | | | PERMITS FOR THE EXTERIOR WORK (INCLUDING, BUT NOT | | | LIMITED TO THE NEW SIDEWALK ACCESS AND RECONFIGURED | | | PARKING STALLS LOCATED ON THE WEST SIDE OF THE ALDI'S | | | BUILDING AND A SEPARATE PERMIT FOR THE WALL SIGNAGE. | | | ALL SCOPE OF WORK SHALL MATCH THE WESTWARD SHOPPING CTR | | | MINOR DSI AMENDMENT APPROVED PLANS (PB 1520G) BY THE | | | PLANNING DIVISION AND PREPARED BY BOHLER ENGINEERING. A | | | FINAL ZONING SIGN-OFF FOR CERTIFICATE OF COMPLETION OR | | | C.O. WILL NOT BE APPROVED, UNLESS PROVISO ABOVE IS | | | ADDRESSED. | | | | | | | | | NOTE TO BOHLER ENGINEERING (MIKE TROXELL): SHEET C-2 | | | SUBMITTED AS PART OF THIS PERMIT WAS REVISED AFTER | | | MARCH 8, 2012. TWO (2) EXTRA REVISED SHEETS OF C-2 WERE | | | SUBMITTED TO THE PLANNING DIVISION. COORDINATE WITH ME | | | TO GET THESE SHEETS BACK OR PROVIDE A SET THAT INCLUDES | | | LATEST REVISED SHEETS, INCLUDING SHEET C-2 WITH SQUARE | | | FOOTAGE REVISION OF TOTAL GROSS BUILDING OF 238, 704. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO, AICP | | | SENIOR PLANNER | | | PLANNING DIVISION | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | | | | | | | | | 2012-04-24 20:12:46 | 4/24/12 ROUTED TO ENGINEERING FOR REVIEW. LMF |
|
|