Plan Review Details - Permit 12030754
| Plan Review Stops For Permit 12030754 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-10 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2012-04-10 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2012-03-30 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2012-04-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-04-04 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-04-04 |
Time |
11:55 |
Sent To |
Z |
|
| Notes |
| 2012-04-04 11:58:18 | PLANS PASS PROVISO | | | REFER TO SECTION 13-409.AB.3.3 SHUT OFF DAMPER | | | CONTROLS. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2012-04-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2012-04-13 |
Time |
14:58 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2012-04-13 |
Time |
14:58 |
Sent To |
PC |
|
| Notes |
| 2012-04-13 15:00:18 | IF AFTER THE INSTALLATION, THE A/C UNIT IS NOT | | | ADEQUATELY SCREENED, THE OWNER HAS AGREED TO INSTALL | | | ADDITIONAL SCREENING. SEE ERIC SCHNEIDER OR GRACE | | | JOYCE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2012-04-10 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2012-04-10 |
Time |
13:37 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2012-04-05 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2012-04-10 14:19:33 | FAILED | | | | | | PROVIDE RESPONSE IN WRITING. | | | | | | 1) THE NORTHWOOD MIXED USE DISTRICT REGULATIONS REQUIRE | | | THAT MECHANICAL SYSTEMS SHALL BE SCREENED FROM VIEW BY | | | LANDSCAPING OR BUILT ELEMENTS DESIGNED AS AN INTEGRAL | | | PART OF THE BUILDING ARCHITECTURE - SECTION | | | 94-213(D)(16) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. INSUFFICIENT INFORMATION WAS PROVIDED TO | | | VERIFY THAT THE PROPOSED 3.5 TON A/C UNIT LOCATED ON | | | THE BUILDING'S ROOF WILL BE SCREENED. PROVIDE A CROSS | | | SECTION, ELEVATION, SITE LINE DRAWING OR OTHER PLAN TO | | | SHOW THE ROOF TOP EQUIPMENT COMPLIES WITH THE SCREENING | | | REQUIREMENT. | | | | | | 2) THE SPECIFICATIONS PROVIDED WITH THE PERMIT FOR THE | | | A/C UNIT AND THE SUPPORT STAND INDICATE THAT THE STAND | | | AND UNIT WILL 42 TO 72 INCHES IN HEIGHT, DEPENDING ON | | | THE MODEL TYPE AND STAND CHOSEN. | | | | | | 3) THE SUBMITTED PICTURES SHOW A PARAPET WITH NO | | | DIMENSIONS, BUT WHICH APPEARS TO BE LESS THAN 30 INCHES | | | HIGH, WHICH WOULD NOT SCREEN THE EQUIPMENT AND STAND | | | MENTIONED IN #2 ABOVE. | | | | | | 4) NO PLAN IS INCLUDED TO SHOW WHERE THE ROOF TOP A/C | | | WILL BE MOUNTED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | 2012-04-05 11:58:27 | GIVEN TO ES |
|
|
|