Plan Review Details - Permit 12030661
Plan Review Stops For Permit 12030661
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-06-22 Cont ID  
Sent By shill Date 2012-06-22 Time 15:42 Rev Time 0.00
Received By shill Date 2012-06-22 Time 15:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-06-12 Cont ID  
Sent By shill Date 2012-06-12 Time 09:56 Rev Time 0.00
Received By shill Date 2012-06-12 Time 09:56 Sent To  
Notes
2012-06-12 10:16:57****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PLEASE PROVIDE DIMENSIONS FOR THE LENGTH OF
 ACCESSIBLE PARKING SPACES AND LENGTH OF ACCESS AISLE,
 FBC ACCESSIBILITY 502.2. AS DRAWN, THE ACCESS AISLE IS
 SHORTER THAN THE PARKING SPACE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-10 Cont ID  
Sent By shill Date 2012-04-10 Time 08:49 Rev Time 0.00
Received By shill Date 2012-04-10 Time 08:48 Sent To  
Notes
2012-04-10 08:55:29****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PROVIDE A DETAIL FOR THE ACCESSIBLE PARKING SPACES.
 THE DETAILS PROVIDED ARE NOT FOR ANGLED PARKING. ON THE
 ROUGH SKETCH PROVIDED, SOME OF THE ACCESSIBLE PARKING
 SPACES SHOWN DO NOT SHOW THE REQUIRED ACCESS AISLE AND
 SOME SHOW A SHORTENED ACCESS AISLE WHICH IS NOT FULL
 LENGTH OF THE ACCESSIBLE SPACE. SEE FBC 2010
 ACCESSIBILITY 502.3.2, 502, 208.
  
 2. THE PLAN SHOULD PROVIDE THE FOLLOWING INFORMATION:
 TOTAL NUMBER OF PARKING SPACES, TOTAL NUMBER OF
 ACCESSIBLE SPACES, FBC 2010 ACCESSIBLITY TABLE 208.2.
  
 3. THE PLAN IS TO INCLUDE THE NAME, SIGNATURE, AND
 LICENSE NUMBER OF THE INDIVIDUAL TAKING RESPONSIBLITY
 FOR THE DESIGN AND ACCURACY OF INFORMATION, FS471, 481,
 489.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-06-26 Cont ID  
Sent By shill Date 2012-06-26 Time 14:39 Rev Time 0.00
Received By shill Date 2012-06-19 Time 15:21 Sent To  
Notes
2012-06-22 15:42:506/22 TO ZONING
  
2012-06-22 11:21:556/22 ON SH DESK
  
2012-06-20 15:21:24TO ZONING
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-06-12 Cont ID  
Sent By shill Date 2012-06-12 Time 10:17 Rev Time 0.00
Received By shill Date 2012-05-24 Time 08:35 Sent To  
Notes
2012-05-24 08:36:03TO ZONING
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-04-10 Cont ID  
Sent By shill Date 2012-04-10 Time 08:55 Rev Time 0.00
Received By shill Date 2012-03-27 Time 17:28 Sent To  
Notes
2012-03-27 17:28:34TO ZONING
  

Review Stop Z ZONING
Rev No 3 Status P Date 2012-06-26 Cont ID  
Sent By eschneid Date 2012-06-26 Time 08:42 Rev Time 0.50
Received By eschneid Date 2012-06-26 Time 08:42 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2012-06-06 Cont ID  
Sent By eschneid Date 2012-06-06 Time 18:19 Rev Time 0.75
Received By eschneid Date 2012-05-29 Time 17:54 Sent To B
Notes
2012-06-06 18:11:55FAILED
  
 1) REPEAT COMMENT - THE SITE PLAN SHALL SHOW PROPERLY
 DIMENSIONED PARKING SPACES AND DRIVE AISLES. THIS IS A
 GENERAL ISSUE ON THE SITE AS THE REGULAR SPACES ARE 10
 FEET WIDE AND THUS UPON AN ANGLE THE SPACES ARE NOT 18
 FEET DEEP. THE REGULAR SPACES THAT ARE PAIRED WITH THE
 ADA SPACES ARE 12 FEET WIDE AND ARE EVEN SHORTER. THE
 DIMENSION TABLE IN THE ZONING AND LAND DEVELOPMENT
 REGULATIONS IS STANDARDIZED FOR SPACES 8.5 FEET IN
 WIDTH AND NEEDS TO BE ADJUSTED FOR WIDER SPACES.
  
 2) REPEAT COMMENT - PLEASE REMEMBER THAT HANDICAP
 PARKING SPACES ARE LARGER THAN REGULAR SPACES AND THAT
 UPON AN ANGLE, THESE SPACES REQUIRE MORE DEPTH THAN
 REGULAR PARKING SPACES. THIS SHALL BE FACTORED INTO THE
 PARKING LOT LAYOUT SO THAT THE CARS DO NOT INTRUDE INTO
 THE DRIVE AISLE.
  
 3) THERE ARE AREAS THAT NO PARKING CAN OCCUR ALONG THE
 NORTHERN TERMINAL ISLANDS WHERE "NO PARKING" STRIPING
 SHALL BE ADDED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
 GIVEN TO ES
2012-05-29 17:55:25GIVEN TO ES

Review Stop Z ZONING
Rev No 1 Status F Date 2012-04-02 Cont ID  
Sent By eschneid Date 2012-04-02 Time 14:52 Rev Time 1.75
Received By eschneid Date 2012-03-30 Time 14:08 Sent To B
Notes
2012-04-02 15:22:54FAILED
  
 1) THE SURVEY PROVIDED IS INSUFFICIENT TO USE AS A SITE
 PLAN. IT SHOWS A NUMBER OF AREAS WITH PARKING STRIPING
 WHICH DO NOT CONFORM TO CITY OF WEST PALM BEACH PARKING
 STANDARDS.
  
 2) THE SITE PLAN SHALL SHOW PROPERLY DIMENSIONED
 PARKING SPACES AND DRIVE AISLES. THE ANGLE OF THE
 PARKING SPACES SHALL ALSO BE INCLUDED ON THE PLANS.
  
 3) PARKING DETAILS WERE ONLY PROVIDED FOR THE 90 DEGREE
 PARKING SPACES. PARKING DETAILS SHALL BE PROVIDED FOR
 EACH PARKING STALL ANGLE USED FOR BOTH THE REGULAR AND
 THE HANDICAP SPACES AND ACCESS AISLES. THE PARKING
 DETAILS SHALL SHOW THE SPACES AS FOUR (4) INCH DOUBLE
 STRIPED WITH TWELVE (12) INCHES BETWEEN THE STRIPES.
 THE PARKING DETAILS SHALL ONLY SHOW WHEEL STOPS IF THEY
 ARE TO BE USED.
  
 4) PLEASE REMEMBER THAT HANDICAP PARKING SPACES ARE
 LARGER THAN REGULAR SPACES AND THAT UPON AN ANGLE,
 THESE SPACES REQUIRE MORE DEPTH THAN REGULAR PARKING
 SPACES. THIS SHALL BE FACTORED INTO THE PARKING LOT
 LAYOUT SO THAT THE CARS DO NOT INTRUDE INTO THE DRIVE
 AISLE.
  
 5) THERE ARE HANDICAP PARKING SPACES SHOWN ON THE
 SURVEY THAT ARE NOT EVIDENT ON THE 2010 AERIAL OF THE
 SITE ON THE PROPERTY APPRAISERS WEB SITE.
  
 6) AN ACCURATE, CURRENT PARKING TABLE SHALL BE PROVIDED
 ON THE SITE PLAN. THE BUILDINGS ON THE SITE REQUIRE 385
 TOTAL PARKING SPACES.
  
 7) THE SPACES WHICH HAVE LIGHT POLES IN THEM SHALL BE
 STRIPPED "NO PARKING" AND THE SITE PLAN SHALL REFLECT
 THIS NOTATION.
  
 8) THE AREA TO THE WEST OF THE PROJECT'S MONUMENT SIGN
 AND SOUTH OF THE ENTRY DRIVE SHALL BE STRIPPED "NO
 PARKING" AND THE SITE PLAN SHALL REFLECT THIS NOTATION.
  
 9) THE SITE PLAN SHALL CLEARLY INDICATE PAVEMENT
 MARKINGS FOR THE ONE-WAY DRIVE AISLE LOCATIONS.
  
 10) A MAXIMUM OF (2) FEET OF A PARKING SPACE MAY
 OVERHANG THE WALKWAY, IF THE CURB IS SIX (6) INCHES OR
 LESS IN HEIGHT. THE PLANS SHOW A FOUR (4) FOOT OVERHANG
 AND SPACES WHICH ARE TOO SHORT.
  
 11) EACH PARKING ROW SHALL BE CLEARLY LABELED WITH THE
 NUMBER OF SPACES IN THE ROW.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2012-03-30 14:09:37GIVEN TO ES